From version < 3.1 >
edited by Xiaoling
on 2023/04/26 08:52
To version < 4.6 >
edited by Xiaoling
on 2023/05/16 09:24
>
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -1,4 +1,5 @@
1 -
1 +(% style="text-align:center" %)
2 +[[image:image-20230516085523-1.jpeg||height="491" width="491"]]
2 2  
3 3  
4 4  **Table of Contents:**
... ... @@ -66,7 +66,6 @@
66 66  * Wall Mountable
67 67  * Outdoor Use
68 68  
69 -
70 70  == 1.3 Specification ==
71 71  
72 72  (% style="color:#037691" %)**Common DC Characteristics:**
... ... @@ -99,7 +99,6 @@
99 99  * Sleep Mode: 5uA @ 3.3v
100 100  * LoRa Transmit Mode: 125mA @ 20dBm, 82mA @ 14dBm
101 101  
102 -
103 103  == 1.4 Applications ==
104 104  
105 105  [[image:Main.User Manual for LoRaWAN End Nodes.LDS03A - Outdoor LoRaWAN OpenClose Door Sensor Manual.WebHome@1654741400370-813.png]]
... ... @@ -173,43 +173,43 @@
173 173  == 2.2 ​Quick guide to connect to LoRaWAN server (OTAA) ==
174 174  
175 175  
176 -Following is an example for how to join the [[TTN v3 LoRaWAN Network>>url:https://console.cloud.thethings.network/]]. Below is the network structure; we use the [[LPS8v2>>url:https://www.dragino.com/products/lora-lorawan-gateway/item/228-lps8v2.html]] as a LoRaWAN gateway in this example.
175 +Following is an example for how to join the [[TTN v3 LoRaWAN Network>>url:https://console.cloud.thethings.network/]]. Below is the network structure; we use the [[LPS8v2>>url:https://www.dragino.com/products/lora-lorawan-gateway/item/228-lps8v2.html]] as a LoRaWAN gateway in this example. (% style="display:none" %)
177 177  
178 -
179 179  The LPS8V2 is already set to connected to [[TTN network >>url:https://console.cloud.thethings.network/]], so what we need to now is configure the TTN server.
180 180  
181 181  
182 -(% style="color:blue" %)**Step 1:**(%%) Create a device in TTN with the OTAA keys from D2x-LB.
180 +(% style="color:blue" %)**Step 1:**(%%) Create a device in TTN with the OTAA keys from DS03A-LB.
183 183  
184 184  Each DS03A-LB is shipped with a sticker with the default device EUI as below:
185 185  
186 -[[image:image-20230131134744-2.jpeg]]
184 +[[image:image-20230426085205-1.png||height="238" width="512"]]
187 187  
188 188  
189 -
190 190  You can enter this key in the LoRaWAN Server portal. Below is TTN screen shot:
191 191  
189 +(% style="display:none" %) (%%)
192 192  
193 193  (% style="color:blue" %)**Register the device**
194 194  
195 -[[image:1675144099263-405.png]]
196 196  
194 +[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/D20-LBD22-LBD23-LB_LoRaWAN_Temperature_Sensor_User_Manual/WebHome/1675144099263-405.png?rev=1.1||alt="1675144099263-405.png"]](% style="display:none" %)
197 197  
196 +
198 198  (% style="color:blue" %)**Add APP EUI and DEV EUI**
199 199  
200 -[[image:1675144117571-832.png]]
199 +[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/D20-LBD22-LBD23-LB_LoRaWAN_Temperature_Sensor_User_Manual/WebHome/1675144117571-832.png?rev=1.1||alt="1675144117571-832.png"]]
201 201  
202 202  
203 203  (% style="color:blue" %)**Add APP EUI in the application**
204 204  
204 +[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/D20-LBD22-LBD23-LB_LoRaWAN_Temperature_Sensor_User_Manual/WebHome/1675144143021-195.png?rev=1.1||alt="1675144143021-195.png"]]
205 205  
206 -[[image:1675144143021-195.png]]
207 207  
208 -
209 209  (% style="color:blue" %)**Add APP KEY**
210 210  
211 -[[image:1675144157838-392.png]]
209 +[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/D20-LBD22-LBD23-LB_LoRaWAN_Temperature_Sensor_User_Manual/WebHome/1675144157838-392.png?rev=1.1||alt="1675144157838-392.png"]]
212 212  
211 +
213 213  (% style="color:blue" %)**Step 2:**(%%) Activate on DS03A-LB
214 214  
215 215  
... ... @@ -294,6 +294,7 @@
294 294  
295 295  === 2.3.2  Real-Time Open/Close Status, Uplink FPORT~=2 ===
296 296  
296 +
297 297  DS03A-LB will send this uplink **after** Device Status once join the LoRaWAN network successfully. And DS03A-LB will send uplinks when:
298 298  
299 299  * Every 2 hours, this interval [[can be changed>>url:http://wiki.dragino.com/xwiki/bin/view/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LDS03A%20-%20Outdoor%20LoRaWAN%20OpenClose%20Door%20Sensor%20Manual/#H3.1A0SetTransmitIntervalTime]].
... ... @@ -301,17 +301,18 @@
301 301  
302 302  Uplink Payload totals 11 bytes.
303 303  
304 -|=(% colspan="5" %)**Real-Time Open/Close Status, FPORT=2**
305 -|**Size(bytes)**|**1**|**3**|**3**|**4**
306 -|**Value**|Status & [[Alarm>>url:http://wiki.dragino.com/xwiki/bin/view/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LDS03A%20-%20Outdoor%20LoRaWAN%20OpenClose%20Door%20Sensor%20Manual/#H3.8A0AlarmBaseonTimeout]]|Total open door events|(((
307 -The last door open
308 -duration (unit: min)
309 -)))|[[Unix TimeStamp>>url:http://wiki.dragino.com/xwiki/bin/view/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LDS03A%20-%20Outdoor%20LoRaWAN%20OpenClose%20Door%20Sensor%20Manual/#H2.4.1A0UnixTimeStamp]]
304 +(% border="1" cellspacing="4" style="background-color:#f2f2f2; width:520px" %)
305 +|=(% colspan="5" style="background-color: rgb(217, 226, 243); color: rgb(0, 112, 192); width: 522px;" %)**Real-Time Open/Close Status, FPORT=2**
306 +|(% style="width:95px" %)**Size(bytes)**|(% style="width:78px" %)**1**|(% style="width:98px" %)**3**|(% style="width:144px" %)**3**|(% style="width:108px" %)**4**
307 +|(% style="width:95px" %)**Value**|(% style="width:78px" %)Status & [[Alarm>>url:http://wiki.dragino.com/xwiki/bin/view/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LDS03A%20-%20Outdoor%20LoRaWAN%20OpenClose%20Door%20Sensor%20Manual/#H3.8A0AlarmBaseonTimeout]]|(% style="width:98px" %)Total open door events|(% style="width:144px" %)(((
308 +The last door open duration (unit: min)
309 +)))|(% style="width:108px" %)[[Unix TimeStamp>>url:http://wiki.dragino.com/xwiki/bin/view/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LDS03A%20-%20Outdoor%20LoRaWAN%20OpenClose%20Door%20Sensor%20Manual/#H2.4.1A0UnixTimeStamp]]
310 310  
311 -|=(% colspan="4" %)**Status & Alarm field**
312 -|**Size(bit)**|**6**|**1**|**1**
313 -|**Value**|Reserve|[[Enable/disable Timeout Alarm>>url:http://wiki.dragino.com/xwiki/bin/view/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LDS03A%20-%20Outdoor%20LoRaWAN%20OpenClose%20Door%20Sensor%20Manual/#H3.8A0AlarmBaseonTimeout]]
314 -0: No Alarm; 1: Alarm|Status
311 +(% border="1" cellspacing="4" style="background-color:#f2f2f2; width:518.818px" %)
312 +|=(% colspan="4" style="background-color: rgb(217, 226, 243); color: rgb(0, 112, 192); width: 516px;" %)**Status & Alarm field**
313 +|(% style="width:76px" %)**Size(bit)**|(% style="width:70px" %)**6**|(% style="width:240px" %)**1**|(% style="width:130px" %)**1**
314 +|(% style="width:76px" %)**Value**|(% style="width:70px" %)Reserve|(% style="width:240px" %)[[Enable/disable Timeout Alarm>>url:http://wiki.dragino.com/xwiki/bin/view/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LDS03A%20-%20Outdoor%20LoRaWAN%20OpenClose%20Door%20Sensor%20Manual/#H3.8A0AlarmBaseonTimeout]]
315 +0: No Alarm; 1: Alarm|(% style="width:130px" %)Status
315 315  0: Close, 1: Open
316 316  
317 317  [[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LDS03A%20-%20Outdoor%20LoRaWAN%20OpenClose%20Door%20Sensor%20Manual/WebHome/image-20220609110547-6.png?width=1191&height=337&rev=1.1||alt="image-20220609110547-6.png" height="337" width="1191"]]
... ... @@ -319,6 +319,7 @@
319 319  
320 320  === 2.3.3  Historical Door Open/Close Event, FPORT~=3 ===
321 321  
323 +
322 322  DS03A-LB stores sensor values and users can retrieve these history values via the [[downlink command>>url:http://wiki.dragino.com/xwiki/bin/view/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LDS03A%20-%20Outdoor%20LoRaWAN%20OpenClose%20Door%20Sensor%20Manual/#H2.4A0DatalogFeature]].
323 323  
324 324  The historical payload includes one or multiplies entries and every entry has the same payload as Real-Time open/close status.
... ... @@ -342,7 +342,6 @@
342 342  **DR3**: total payload includes 22 entries of data.
343 343  )))
344 344  
345 -
346 346  If DS03A-LB doesn't have any data in the polling time. It will uplink 11 bytes of 0
347 347  
348 348  [[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LDS03A%20-%20Outdoor%20LoRaWAN%20OpenClose%20Door%20Sensor%20Manual/WebHome/image-20220609112215-7.png?width=1250&height=277&rev=1.1||alt="image-20220609112215-7.png" height="277" width="1250"]]
... ... @@ -385,13 +385,16 @@
385 385  
386 386  === 2.3.4  Sensor Configuration, FPORT~=4 ===
387 387  
389 +
388 388  DS03A-LB will only send this command after getting the downlink command (0x26 02) from the server.
389 389  
390 -[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LDS03A%20-%20Outdoor%20LoRaWAN%20OpenClose%20Door%20Sensor%20Manual/WebHome/image-20220609110123-5.png?rev=1.1||alt="image-20220609110123-5.png"]]
392 +(% border="1" cellspacing="4" style="background-color:#f2f2f2; width:510px" %)
393 +|(% colspan="5" style="background-color:#d9e2f3; color:#0070c0; width:504px" %)**Sensor Configuration FPORT=4**
394 +|**Size(bytes)**|(% style="width:75px" %)**3**|(% style="width:77px" %)**1**|(% style="width:96px" %)**1**|(% style="width:158px" %)**2**
395 +|**Value**|(% style="width:75px" %)TDC (unit:sec)|(% style="width:77px" %)Disalarm|(% style="width:96px" %)Keep status|(% style="width:158px" %)Keep time (unit: min)
391 391  
392 -
393 393  * (((
394 -**TDC: (default: 0x001C20)**
398 +(% style="color:blue" %)**TDC: (default: 0x001C20)**
395 395  )))
396 396  
397 397  Uplink interval for the Open/Close Event, default value is 0x001C20 which is 7200 seconds = 2 hours.
... ... @@ -398,7 +398,7 @@
398 398  
399 399  
400 400  * (((
401 -**Disalarm: (default: 0)**
405 +(% style="color:blue" %)**Disalarm: (default: 0)**
402 402  )))
403 403  
404 404   **If Disalarm = 1**, DS03A-LB will only send uplink at every TDC periodically. This is normally use for pulse meter application, in this application, there are many open/close event, and platform only care about the total number of pulse.
... ... @@ -406,11 +406,11 @@
406 406   **If Disalarm = 0**, DS03A-LB will send uplink at every TDC periodically and send data on each open/close event. This is useful for the application user need to monitor the open/close event in real-time.
407 407  
408 408  
409 -**~ Note: When Disalarm=0, a high frequently open/close event will cause lots of uplink and drain battery very fast. **
413 +(% style="color:red" %)** Note: When Disalarm=0, a high frequently open/close event will cause lots of uplink and drain battery very fast. **
410 410  
411 411  
412 412  * (((
413 -**Keep Status & Keep Time**
417 +(% style="color:blue" %)**Keep Status & Keep Time**
414 414  )))
415 415  
416 416  Shows the configure value of [[Alarm Base on Timeout Feature>>url:http://wiki.dragino.com/xwiki/bin/view/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LDS03A%20-%20Outdoor%20LoRaWAN%20OpenClose%20Door%20Sensor%20Manual/#H3.8A0AlarmBaseonTimeout]]
... ... @@ -433,7 +433,7 @@
433 433  == 2.5 Datalog Feature ==
434 434  
435 435  
436 -**Datalog Feature** is to ensure IoT Server can get all sampling data from Sensor even if the LoRaWAN network is down. For each sampling, DS03A-LB will store the reading for future retrieving purposes.
440 +(% style="color:blue" %)**Datalog Feature** (%%)is to ensure IoT Server can get all sampling data from Sensor even if the LoRaWAN network is down. For each sampling, DS03A-LB will store the reading for future retrieving purposes.
437 437  
438 438  
439 439  === 2.5.1 Ways to get datalog via LoRaWAN ===
... ... @@ -479,9 +479,9 @@
479 479  Datacake IoT platform provides a human-friendly interface to show the sensor data, once we have sensor data in TTN V3, we can use Datacake to connect to TTN V3 and see the data in Datacake. Below are the steps:
480 480  
481 481  
482 -**Step 1: Link TTNv3 to Datacake.**[[https:~~/~~/docs.datacake.de/lorawan/lns/thethingsindustries#create-integration-on-tti>>url:https://docs.datacake.de/lorawan/lns/thethingsindustries#create-integration-on-tti]]
486 +(% style="color:blue" %)**Step 1:**(%%)** Link TTNv3 to Datacake.**[[https:~~/~~/docs.datacake.de/lorawan/lns/thethingsindustries#create-integration-on-tti>>url:https://docs.datacake.de/lorawan/lns/thethingsindustries#create-integration-on-tti]]
483 483  
484 -**Step 2: Configure DS03A-LB in Datacake.**
488 +(% style="color:blue" %)**Step 2:**(%%)** Configure DS03A-LB in Datacake.**
485 485  
486 486  [[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LDS03A%20-%20Outdoor%20LoRaWAN%20OpenClose%20Door%20Sensor%20Manual/WebHome/1654746350207-427.png?rev=1.1||alt="1654746350207-427.png"]]
487 487  
... ... @@ -531,7 +531,6 @@
531 531  * AT Command via UART Connection : See [[Connection>>http://wiki.dragino.com/xwiki/bin/view/Main/UART%20Access%20for%20LoRa%20ST%20v4%20base%20model/#H2.3UARTConnectionforSN50v3basemotherboard]].
532 532  * LoRaWAN Downlink.  Instruction for different platforms: See [[IoT LoRaWAN Server>>http://wiki.dragino.com/xwiki/bin/view/Main/]] section.
533 533  
534 -
535 535  == 3.2 General Commands ==
536 536  
537 537  These commands are to configure:
... ... @@ -638,7 +638,6 @@
638 638  **AT+TTRIG=0,0**   **~-~-> ** Default Value, disable timeout Alarm.
639 639  )))
640 640  
641 -
642 642  **Downlink Command to configure:**
643 643  
644 644  **Command: 0xA9 aa bb cc**
... ... @@ -780,7 +780,6 @@
780 780  OK
781 781  )))
782 782  
783 -
784 784  = 4. Battery & Power Consumption =
785 785  
786 786  
... ... @@ -806,7 +806,6 @@
806 806  * (Recommanded way) OTA firmware update via wireless: [[http:~~/~~/wiki.dragino.com/xwiki/bin/view/Main/Firmware%20OTA%20Update%20for%20Sensors/>>url:http://wiki.dragino.com/xwiki/bin/view/Main/Firmware%20OTA%20Update%20for%20Sensors/]]
807 807  * Update through UART TTL interface. **[[Instruction>>url:http://wiki.dragino.com/xwiki/bin/view/Main/UART%20Access%20for%20LoRa%20ST%20v4%20base%20model/#H1.LoRaSTv4baseHardware]]**.
808 808  
809 -
810 810  = 6. FAQ =
811 811  
812 812  
image-20230516085523-1.jpeg
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Xiaoling
Size
... ... @@ -1,0 +1,1 @@
1 +1.3 MB
Content
Copyright ©2010-2024 Dragino Technology Co., LTD. All rights reserved
Dragino Wiki v2.0