Changes for page DS03A-LB/LS -- Outdoor LoRaWAN Door Sensor User Manual
Last modified by Mengting Qiu on 2025/01/10 09:53
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -304,47 +304,9 @@ 304 304 Ex2: 0x0B49 = 2889mV 305 305 306 306 307 -=== (% id="cke_bm_182700S" style="display:none" %) (%%)2.3.2SensorConfiguration,FPORT~=4===307 +=== 2.3.2 Real-Time Open/Close Status, Uplink FPORT~=2 === 308 308 309 309 310 -DS03A-LB will only send this command after getting the downlink command (0x26 02) from the server. 311 - 312 -(% border="1" cellspacing="4" style="background-color:#f2f2f2; width:510px" %) 313 -|(% colspan="5" style="background-color:#d9e2f3; color:#0070c0; width:504px" %)**Sensor Configuration FPORT=4** 314 -|**Size(bytes)**|(% style="width:75px" %)**3**|(% style="width:77px" %)**1**|(% style="width:96px" %)**1**|(% style="width:158px" %)**2** 315 -|**Value**|(% style="width:75px" %)TDC (unit:sec)|(% style="width:77px" %)Disalarm|(% style="width:96px" %)Keep status|(% style="width:158px" %)Keep time (unit: min) 316 - 317 -* ((( 318 -(% style="color:blue" %)**TDC: (default: 0x001C20)** 319 -))) 320 - 321 -Uplink interval for the Open/Close Event, default value is 0x001C20 which is 7200 seconds = 2 hours. 322 - 323 - 324 -* ((( 325 -(% style="color:blue" %)**Disalarm: (default: 0)** 326 -))) 327 - 328 - **If Disalarm = 1**, DS03A-LB will only send uplink at every TDC periodically. This is normally use for pulse meter application, in this application, there are many open/close event, and platform only care about the total number of pulse. 329 - 330 - **If Disalarm = 0**, DS03A-LB will send uplink at every TDC periodically and send data on each open/close event. This is useful for the application user need to monitor the open/close event in real-time. 331 - 332 - 333 -(% style="color:red" %)** Note: When Disalarm=0, a high frequently open/close event will cause lots of uplink and drain battery very fast. ** 334 - 335 - 336 -* ((( 337 -(% style="color:blue" %)**Keep Status & Keep Time** 338 -))) 339 - 340 -Shows the configure value of [[Alarm Base on Timeout Feature>>url:http://wiki.dragino.com/xwiki/bin/view/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LDS03A%20-%20Outdoor%20LoRaWAN%20OpenClose%20Door%20Sensor%20Manual/#H3.8A0AlarmBaseonTimeout]] 341 - 342 -[[image:image-20230630155527-3.png||height="146" width="902"]] 343 - 344 - 345 -=== 2.3.3 Real-Time Open/Close Status, Uplink FPORT~=2 === 346 - 347 - 348 348 DS03A-LB will send this uplink **after** Device Status once join the LoRaWAN network successfully. And DS03A-LB will send uplinks when: 349 349 350 350 * Every 2 hours, this interval [[can be changed>>||anchor="H3.3.1SetTransmitIntervalTime"]]. ... ... @@ -375,7 +375,7 @@ 375 375 [[image:image-20230630155908-6.png||height="295" width="927"]] 376 376 377 377 378 -=== 2.3. 4Historical Door Open/Close Event, FPORT~=3 ===340 +=== 2.3.3 Historical Door Open/Close Event, FPORT~=3 === 379 379 380 380 381 381 DS03A-LB stores sensor values and users can retrieve these history values via the [[downlink command>>||anchor="H2.5DatalogFeature"]]. ... ... @@ -440,6 +440,44 @@ 440 440 [[image:image-20230630155751-5.png||height="188" width="809"]] 441 441 442 442 405 +=== 2.3.4 Sensor Configuration, FPORT~=4 === 406 + 407 + 408 +DS03A-LB will only send this command after getting the downlink command (0x26 02) from the server. 409 + 410 +(% border="1" cellspacing="4" style="background-color:#f2f2f2; width:510px" %) 411 +|(% colspan="5" style="background-color:#d9e2f3; color:#0070c0; width:504px" %)**Sensor Configuration FPORT=4** 412 +|**Size(bytes)**|(% style="width:75px" %)**3**|(% style="width:77px" %)**1**|(% style="width:96px" %)**1**|(% style="width:158px" %)**2** 413 +|**Value**|(% style="width:75px" %)TDC (unit:sec)|(% style="width:77px" %)Disalarm|(% style="width:96px" %)Keep status|(% style="width:158px" %)Keep time (unit: min) 414 + 415 +* ((( 416 +(% style="color:blue" %)**TDC: (default: 0x001C20)** 417 +))) 418 + 419 +Uplink interval for the Open/Close Event, default value is 0x001C20 which is 7200 seconds = 2 hours. 420 + 421 + 422 +* ((( 423 +(% style="color:blue" %)**Disalarm: (default: 0)** 424 +))) 425 + 426 + **If Disalarm = 1**, DS03A-LB will only send uplink at every TDC periodically. This is normally use for pulse meter application, in this application, there are many open/close event, and platform only care about the total number of pulse. 427 + 428 + **If Disalarm = 0**, DS03A-LB will send uplink at every TDC periodically and send data on each open/close event. This is useful for the application user need to monitor the open/close event in real-time. 429 + 430 + 431 +(% style="color:red" %)** Note: When Disalarm=0, a high frequently open/close event will cause lots of uplink and drain battery very fast. ** 432 + 433 + 434 +* ((( 435 +(% style="color:blue" %)**Keep Status & Keep Time** 436 +))) 437 + 438 +Shows the configure value of [[Alarm Base on Timeout Feature>>url:http://wiki.dragino.com/xwiki/bin/view/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LDS03A%20-%20Outdoor%20LoRaWAN%20OpenClose%20Door%20Sensor%20Manual/#H3.8A0AlarmBaseonTimeout]] 439 + 440 +[[image:image-20230630155527-3.png||height="146" width="902"]] 441 + 442 + 443 443 == 2.4 Payload Decoder file == 444 444 445 445