... ... @@ -736,9 +736,11 @@
736 736  )))
737 737  
738 738  
739 +
739 739  === 3.2.6  Alarm Mode ===
740 740  
741 741  
743 +
742 742  **Feature**: When the sample temperature is lower or higher than the set threshold, it will automatically alarm (the alarm mode is only for food temperature).
743 743  
744 744  (% style="color:#4f81bd" %)**Downlink Command: 0x09**
... ... @@ -745,50 +745,13 @@
745 745  
746 746  Format: Command Code (0x09) followed by 4 bytes.
747 747  
748 -Example: 09 aa aa bb bb
750 +* Example: 0x09 00 14 00  15  ~/~/ Confirmed Mode enabled.
751 +* Example: 0x07 00  ~/~/  Confirmed Mode disable.
749 749  
750 -(% border="1" cellspacing="4" style="background-color:#f2f2f2; width:510px" %)
751 -|=(% style="width: 155px;background-color:#4F81BD;color:white" %)**Parameter**|=(% style="width: 197px;background-color:#4F81BD;color:white" %)**Function**
752 -|(% style="width:154px" %)aa aa|(% style="width:196px" %)(((
753 -Minimum temperature threshold
754 754  
755 -(Minimum not to exceed: -30℃)
756 -)))
757 -|(% style="width:154px" %)bb bb|(% style="width:196px" %)(((
758 -Maximum temperature threshold
759 759  
760 -(Maximum not to exceed: 120℃)
761 -)))
762 762  
763 -* Example: 0x09 00 14 00 15  ~/~/ Set the minimum threshold to 20℃ and the maximum threshold to 25℃
764 -* Example: 0x09 00 00 00 00  ~/~/  Disable threshold alarm mode
765 765  
766 -Note:
767 -
768 -* When the temperature exceeds the set minimum and maximum temperature thresholds, sampling will be performed at an interval of every 6 seconds. Each set of temperature data will be immediately uploaded to the server.
769 -* The set minimum and maximum alarm temperatures must be within the food temperature range. The temperature detection range is -30 to 120°C.
770 -
771 -
772 -
773 -=== 3.2.7 Multi sampling ===
774 -
775 -Feature: Sampling multiple times and uplink together.
776 -
777 -Format: Command Code (0x0A) followed by 3 bytes.
778 -
779 -Example: 0A aa aa bb
780 -
781 -(% border="1" cellspacing="4" style="background-color:#f2f2f2; width:510px" %)
782 -|=(% style="width: 155px;background-color:#4F81BD;color:white" %)**Parameter**|=(% style="width: 197px;background-color:#4F81BD;color:white" %)**Function**
783 -|(% style="width:154px" %)aa aa|(% style="width:196px" %)Sampling interval (range: 6~~65535s)
784 -|(% style="width:154px" %)bb bb|(% style="width:196px" %)(((
785 -Maximum temperature threshold
786 -
787 -(Maximum not to exceed: 120℃)
788 -)))
789 -
790 -
791 -
792 792  = 4. Firmware update =
793 793  
794 794