772 772  
773 773  === 3.2.7 Multi sampling ===
774 774  
775 -**Feature**When the sample temperature is lower or higher than the set threshold, it will automatically alarm (the alarm mode is only for food temperature).
775 +Feature: Sampling multiple times and uplink together.
776 776  
777 +Format: Command Code (0x0A) followed by 3 bytes.
777 777  
779 +Example: 0A aa aa bb
778 778  
781 +(% border="1" cellspacing="4" style="background-color:#f2f2f2; width:510px" %)
782 +|=(% style="width: 155px;background-color:#4F81BD;color:white" %)**Parameter**|=(% style="width: 197px;background-color:#4F81BD;color:white" %)**Function**
783 +|(% style="width:154px" %)aa aa|(% style="width:196px" %)Sampling interval (range: 6~~65535s)
784 +|(% style="width:154px" %)bb bb|(% style="width:196px" %)(((
785 +Maximum temperature threshold
779 779  
787 +(Maximum not to exceed: 120℃)
788 +)))