Changes for page DMT01

Last modified by Mengting Qiu on 2025/08/11 18:25

From version 67.5
edited by Mengting Qiu
on 2025/08/06 18:11
Change comment: There is no comment for this version
To version 68.1
edited by Mengting Qiu
on 2025/08/06 18:21
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -746,11 +746,21 @@
746 746  
747 747  Format: Command Code (0x09) followed by 4 bytes.
748 748  
749 +Example: 09 aa aa bb bb
750 +
749 749  (% border="1" cellspacing="4" style="background-color:#f2f2f2; width:510px" %)
750 -|=(% style="width: 155px;background-color:#4F81BD;color:white" %)**Command Example**|=(% style="width: 197px;background-color:#4F81BD;color:white" %)**Function**
751 -|(% style="width:154px" %)AT+3V3T=?|(% style="width:196px" %)Show 3.3V open time.
752 -|(% style="width:154px" %)AT+3V3T=1000|(% style="width:196px" %)Close after a delay of 1000 milliseconds.
752 +|=(% style="width: 155px;background-color:#4F81BD;color:white" %)**Parameter**|=(% style="width: 197px;background-color:#4F81BD;color:white" %)**Function**
753 +|(% style="width:154px" %)aa aa|(% style="width:196px" %)(((
754 +Minimum temperature threshold
753 753  
756 +(Minimum not to exceed: -30℃)
757 +)))
758 +|(% style="width:154px" %)bb bb|(% style="width:196px" %)(((
759 +Maximum temperature threshold
760 +
761 +(Maximum not to exceed: 120℃)
762 +)))
763 +
754 754  * Example: 0x09 00 14 00 15  ~/~/ Set the minimum threshold to 20℃ and the maximum threshold to 25℃
755 755  * Example: 0x09 00 00 00 00  ~/~/  Disable threshold alarm mode
756 756  
... ... @@ -761,9 +761,13 @@
761 761  
762 762  
763 763  
774 +=== 3.2.7 Multi sampling ===
764 764  
776 +**Feature**: When the sample temperature is lower or higher than the set threshold, it will automatically alarm (the alarm mode is only for food temperature).
765 765  
766 766  
779 +
780 +
767 767  = 4. Firmware update =
768 768  