Changes for page DMT01
Last modified by Mengting Qiu on 2025/08/11 18:25
From version 67.2
edited by Mengting Qiu
on 2025/08/06 18:03
on 2025/08/06 18:03
Change comment:
There is no comment for this version
To version 66.4
edited by Mengting Qiu
on 2025/08/06 17:49
on 2025/08/06 17:49
Change comment:
There is no comment for this version
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -745,19 +745,15 @@ 745 745 746 746 (% style="color:#4f81bd" %)**Downlink Command: 0x09** 747 747 748 -Format: Command Code (0x09) followed by 4bytes.748 +Format: Command Code (0x09) followed by 3 bytes. 749 749 750 -* Example: 0x09 0 0140015~/~/Set the minimum thresholdto20℃ andthemaximum thresholdto 25℃751 -* Example: 0x0 90000 00 00~/~/Disablethreshold alarm mode750 +* Example: 0x09 01 ~/~/ Confirmed Mode enabled. 751 +* Example: 0x07 00 ~/~/ Confirmed Mode disable. 752 752 753 -Note: 754 754 755 -* When the temperature exceeds the set minimum and maximum temperature thresholds, sampling will be performed at an interval of every 6 seconds. Each set of temperature data will be immediately uploaded to the server. 756 -* The set minimum and maximum alarm temperatures must be within the food temperature range. The temperature detection range is -30 to 120°C. 757 757 758 758 759 759 760 - 761 761 = 4. Firmware update = 762 762 763 763