Changes for page DMT01
Last modified by Mengting Qiu on 2025/08/11 18:25
From version 66.6
edited by Mengting Qiu
on 2025/08/06 17:52
on 2025/08/06 17:52
Change comment:
There is no comment for this version
To version 67.3
edited by Mengting Qiu
on 2025/08/06 18:05
on 2025/08/06 18:05
Change comment:
There is no comment for this version
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -740,7 +740,6 @@ 740 740 === 3.2.6 Alarm Mode === 741 741 742 742 743 - 744 744 **Feature**: When the sample temperature is lower or higher than the set threshold, it will automatically alarm (the alarm mode is only for food temperature). 745 745 746 746 (% style="color:#4f81bd" %)**Downlink Command: 0x09** ... ... @@ -750,10 +750,14 @@ 750 750 * Example: 0x09 00 14 00 15 ~/~/ Set the minimum threshold to 20℃ and the maximum threshold to 25℃ 751 751 * Example: 0x09 00 00 00 00 ~/~/ Disable threshold alarm mode 752 752 752 +Note: 753 753 754 +* When the temperature exceeds the set minimum and maximum temperature thresholds, sampling will be performed at an interval of every 6 seconds. Each set of temperature data will be immediately uploaded to the server. 755 +* The set minimum and maximum alarm temperatures must be within the food temperature range. The temperature detection range is -30 to 120°C. 754 754 755 755 756 756 759 + 757 757 = 4. Firmware update = 758 758 759 759