Changes for page DMT01

Last modified by Xiaoling on 2025/08/15 17:26

From version 66.3
edited by Mengting Qiu
on 2025/08/06 17:47
Change comment: There is no comment for this version
To version 67.3
edited by Mengting Qiu
on 2025/08/06 18:05
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -740,18 +740,23 @@
740 740  === 3.2.6  Alarm Mode ===
741 741  
742 742  
743 -
744 744  **Feature**: When the sample temperature is lower or higher than the set threshold, it will automatically alarm (the alarm mode is only for food temperature).
745 745  
746 746  (% style="color:#4f81bd" %)**Downlink Command: 0x09**
747 747  
748 -* Example: 0x09 01  ~/~/ Confirmed Mode enabled.
749 -* Example: 0x07 00  ~/~/  Confirmed Mode disable.
747 +Format: Command Code (0x09) followed by 4 bytes.
750 750  
749 +* Example: 0x09 00 14 00 15  ~/~/ Set the minimum threshold to 20℃ and the maximum threshold to 25℃
750 +* Example: 0x09 00 00 00 00  ~/~/  Disable threshold alarm mode
751 751  
752 +Note:
752 752  
754 +* When the temperature exceeds the set minimum and maximum temperature thresholds, sampling will be performed at an interval of every 6 seconds. Each set of temperature data will be immediately uploaded to the server.
755 +* The set minimum and maximum alarm temperatures must be within the food temperature range. The temperature detection range is -30 to 120°C.
753 753  
754 754  
758 +
759 +
755 755  = 4. Firmware update =
756 756  
757 757