743 +**Feature**: When the sample temperature is lower or higher than the set threshold, it will automatically alarm (the alarm mode is only for food temperature).
743 743  
745 +(% style="color:#4f81bd" %)**Downlink Command: 0x09**
744 744  
747 +Format: Command Code (0x09) followed by 4 bytes.
745 745  
749 +Example: 09 aa aa bb bb
750 +
751 +(% border="1" cellspacing="4" style="background-color:#f2f2f2; width:510px" %)
752 +|=(% style="width: 155px;background-color:#4F81BD;color:white" %)**Parameter**|=(% style="width: 197px;background-color:#4F81BD;color:white" %)**Function**
753 +|(% style="width:154px" %)aa aa|(% style="width:196px" %)Show 3.3V open time.
754 +|(% style="width:154px" %)bb bb|(% style="width:196px" %)Close after a delay of 1000 milliseconds.
755 +
756 +* Example: 0x09 00 14 00 15  ~/~/ Set the minimum threshold to 20℃ and the maximum threshold to 25℃
757 +* Example: 0x09 00 00 00 00  ~/~/  Disable threshold alarm mode
758 +
759 +Note:
760 +
761 +* When the temperature exceeds the set minimum and maximum temperature thresholds, sampling will be performed at an interval of every 6 seconds. Each set of temperature data will be immediately uploaded to the server.
762 +* The set minimum and maximum alarm temperatures must be within the food temperature range. The temperature detection range is -30 to 120°C.