Changes for page DMT01

Last modified by Xiaoling on 2025/08/16 17:21

From version 66.1
edited by Mengting Qiu
on 2025/08/06 17:25
Change comment: There is no comment for this version
To version 66.6
edited by Mengting Qiu
on 2025/08/06 17:52
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -741,8 +741,19 @@
741 741  
742 742  
743 743  
744 +**Feature**: When the sample temperature is lower or higher than the set threshold, it will automatically alarm (the alarm mode is only for food temperature).
744 744  
746 +(% style="color:#4f81bd" %)**Downlink Command: 0x09**
745 745  
748 +Format: Command Code (0x09) followed by 4 bytes.
749 +
750 +* Example: 0x09 00 14 00 15  ~/~/ Set the minimum threshold to 20℃ and the maximum threshold to 25℃
751 +* Example: 0x09 00 00 00 00  ~/~/  Disable threshold alarm mode
752 +
753 +
754 +
755 +
756 +
746 746  = 4. Firmware update =
747 747  
748 748