... ... @@ -631,14 +631,17 @@
631 631  
632 632  **Message Type** is 0x40 = POLL_REPLY
633 633  
634 -tempDataLength is 0x28 = 40(Represents the total number of temperature bytes of the current group)
634 +**tempDataLength **is 0x28 = 40(Represents the total number of temperature bytes of the current group)
635 635  
636 -Food temperature is 0xE000 = 00E0/10 = 22.4℃
636 +**Food temperature** is 0xE000 = 00E0/10 = 22.4℃
637 637  
638 -Ambient temperature
638 +**Ambient temperature** is 0xEA00 = 0x00EA/10=23.4℃
639 639  
640 +**Food temperature** is 0xDF00 = 00FD/10 = 25.3℃
640 640  
641 -
642 +**Ambient temperature** is 0xEA00 = 0x00EA/10=23.4℃
643 +
644 +One set of data contains 10 sets of data, and so on...
642 642  )))
643 643  
644 644  
... ... @@ -733,13 +733,47 @@
733 733  )))
734 734  
735 735  
736 -
737 737  === 3.2.6  Alarm Mode ===
738 738  
739 739  
742 +**Feature**: When the sample temperature is lower or higher than the set threshold, it will automatically alarm (the alarm mode is only for food temperature).
740 740  
744 +(% style="color:#4f81bd" %)**Downlink Command: 0x09**
741 741  
746 +Format: Command Code (0x09) followed by 4 bytes.
742 742  
748 +Example: 09 aa aa bb bb
749 +
750 +(% border="1" cellspacing="4" style="background-color:#f2f2f2; width:510px" %)
751 +|=(% style="width: 155px;background-color:#4F81BD;color:white" %)**Parameter**|=(% style="width: 197px;background-color:#4F81BD;color:white" %)**Function**
752 +|(% style="width:154px" %)aa aa|(% style="width:196px" %)(((
753 +Minimum temperature threshold
754 +
755 +(Minimum not to exceed: -30℃)
756 +)))
757 +|(% style="width:154px" %)bb bb|(% style="width:196px" %)(((
758 +Maximum temperature threshold
759 +
760 +(Maximum not to exceed: 120℃)
761 +)))
762 +
763 +* Example: 0x09 00 14 00 15  ~/~/ Set the minimum threshold to 20℃ and the maximum threshold to 25℃
764 +* Example: 0x09 00 00 00 00  ~/~/  Disable threshold alarm mode
765 +
766 +Note:
767 +
768 +* When the temperature exceeds the set minimum and maximum temperature thresholds, sampling will be performed at an interval of every 6 seconds. Each set of temperature data will be immediately uploaded to the server.
769 +* The set minimum and maximum alarm temperatures must be within the food temperature range. The temperature detection range is -30 to 120°C.
770 +
771 +
772 +
773 +=== 3.2.7 Multi sampling ===
774 +
775 +**Feature**: When the sample temperature is lower or higher than the set threshold, it will automatically alarm (the alarm mode is only for food temperature).
776 +