Content
... ... @@ -37,7 +37,6 @@
37 37  * Support various network structures
38 38  
39 39  
40 -
41 41  == 1.3 What can you learn from the kit? ==
42 42  
43 43  
... ... @@ -58,7 +58,6 @@
58 58  * Learn different way to connect LoRaWAN network to IoT Server and compare their advantages / disadvantages.
59 59  
60 60  
61 -
62 62  == 1.4 What parts Dragino LoRa IoT v3 includes? ==
63 63  
64 64  
... ... @@ -85,7 +85,6 @@
85 85  * 20 x dupont cable (male to female)
86 86  
87 87  
88 -
89 89  = 2. Example 1: Test a LoRaWAN network =
90 90  
91 91  
... ... @@ -210,7 +210,6 @@
210 210  (% style="color:#037691" %)**AT+RXMOD=6,0   ** (%%) ~-~->  Rx Timeout and Reply mode
211 211  )))
212 212  
213 -
214 214  === 5.1.2 Hardware Connection ===
215 215  
216 216  
... ... @@ -347,7 +347,6 @@
347 347  
348 348  
349 349  LA66 USB is loaded with the firmware **[[LA66 USB use LoRaWAN firmware>>url:https://www.dropbox.com/sh/els49fz9rd6fu1y/AAAt-kKIvXu1ZOK0hWysq97na?dl=0]]** and user can use AT Command to set up LA66 with below parameters:
350 -
351 351  (% class="box infomessage" %)
352 352  (((
353 353  (% style="color:#037691" %)**AT+CHS=904100000** (%%) ~-~->  Fix frequency
... ... @@ -358,7 +358,6 @@
358 358  
359 359  (% style="color:#037691" %)**AT+DR=0 ** (%%) ~-~->  Fix DR=0
360 360  )))
361 -
362 362  Set up LA66 USB t work in ABP mode, use fix frequency(904100000) and fix DR0(SF10) to transmit data.
363 363  
364 364  
... ... @@ -366,7 +366,6 @@
366 366  
367 367  
368 368  LA66 Shield is loaded with the firmware **[[LA66 Shield use Point to Point firmware>>url:https://www.dropbox.com/sh/els49fz9rd6fu1y/AAAt-kKIvXu1ZOK0hWysq97na?dl=0]]**, LA66 Shield as Relay needs to be configured as follows:
369 -
370 370  (% class="box infomessage" %)
371 371  (((
372 372  (% style="color:#037691" %)**AT+FRE=904.100,904.100**(%%)  ~-~-> TX and RX frequency set: 904100000 
... ... @@ -392,7 +392,6 @@
392 392  (% style="color:#037691" %)**AT+WAITTIME=1000**(%%)  ~-~-> Relay wait time 1000ms