Changes for page LoRaWAN IoT Kit v3 User Manual
Last modified by Xiaoling on 2023/07/24 09:53
From version 33.1
edited by Kilight Cao
on 2022/11/21 17:59
on 2022/11/21 17:59
Change comment:
There is no comment for this version
To version 36.1
edited by Kilight Cao
on 2023/07/18 16:14
on 2023/07/18 16:14
Change comment:
Uploaded new attachment "image-20230718161437-3.png", version {1}
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 2 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -37,6 +37,7 @@ 37 37 * Support various network structures 38 38 39 39 40 + 40 40 == 1.3 What can you learn from the kit? == 41 41 42 42 ... ... @@ -57,6 +57,7 @@ 57 57 * Learn different way to connect LoRaWAN network to IoT Server and compare their advantages / disadvantages. 58 58 59 59 61 + 60 60 == 1.4 What parts Dragino LoRa IoT v3 includes? == 61 61 62 62 ... ... @@ -83,6 +83,7 @@ 83 83 * 20 x dupont cable (male to female) 84 84 85 85 88 + 86 86 = 2. Example 1: Test a LoRaWAN network = 87 87 88 88 ... ... @@ -123,21 +123,20 @@ 123 123 124 124 TTN v3 stack has the same configure method as the public TTN server. When user test example 2 here. User need to log in the TTNv3 stack in LPS8v2 as per below: 125 125 126 -**Input URL( __http:~/~/<hostname>:8080 or http:~/~/<local-IPV4-address> __) in your browser.** 129 +**Input URL( (% style="background-color:yellow" %)//__http:~/~/<hostname>:8080 or http:~/~/<local-IPV4-address>__//(%%)__ __) in your browser.** 127 127 128 -**Such as __http:~/~/dragino-54ff12:8080 or http:~/~/<Local-IPV4-Address>__** 131 +**Such as (% style="background-color:yellow" %)//__http:~/~/dragino-54ff12:8080 or http:~/~/<Local-IPV4-Address>__//(%%)** 129 129 130 130 131 131 (% style="color:blue" %)**Login account:** 132 132 133 -**User ID: admin** 136 +**User ID: (% style="background-color:yellow" %)admin(%%)** 134 134 135 -**Password: dragino** 138 +**Password: (% style="background-color:yellow" %)dragino(%%)** 136 136 137 137 [[image:1669019821266-501.png]] 138 138 139 139 140 - 141 141 = 4. Example 3: Test Built-in LoRaWAN server and Application server = 142 142 143 143 ... ... @@ -207,6 +207,7 @@ 207 207 (% style="color:#037691" %)**AT+RXMOD=6,0 ** (%%) ~-~-> Rx Timeout and Reply mode 208 208 ))) 209 209 212 + 210 210 === 5.1.2 Hardware Connection === 211 211 212 212 ... ... @@ -343,6 +343,7 @@ 343 343 344 344 345 345 LA66 USB is loaded with the firmware **[[LA66 USB use LoRaWAN firmware>>url:https://www.dropbox.com/sh/els49fz9rd6fu1y/AAAt-kKIvXu1ZOK0hWysq97na?dl=0]]** and user can use AT Command to set up LA66 with below parameters: 349 + 346 346 (% class="box infomessage" %) 347 347 ((( 348 348 (% style="color:#037691" %)**AT+CHS=904100000** (%%) ~-~-> Fix frequency ... ... @@ -353,6 +353,7 @@ 353 353 354 354 (% style="color:#037691" %)**AT+DR=0 ** (%%) ~-~-> Fix DR=0 355 355 ))) 360 + 356 356 Set up LA66 USB t work in ABP mode, use fix frequency(904100000) and fix DR0(SF10) to transmit data. 357 357 358 358 ... ... @@ -360,6 +360,7 @@ 360 360 361 361 362 362 LA66 Shield is loaded with the firmware **[[LA66 Shield use Point to Point firmware>>url:https://www.dropbox.com/sh/els49fz9rd6fu1y/AAAt-kKIvXu1ZOK0hWysq97na?dl=0]]**, LA66 Shield as Relay needs to be configured as follows: 368 + 363 363 (% class="box infomessage" %) 364 364 ((( 365 365 (% style="color:#037691" %)**AT+FRE=904.100,904.100**(%%) ~-~-> TX and RX frequency set: 904100000 ... ... @@ -385,6 +385,7 @@ 385 385 (% style="color:#037691" %)**AT+WAITTIME=1000**(%%) ~-~-> Relay wait time 1000ms 386 386 ))) 387 387 394 + 388 388 == 7.3 Uplink test == 389 389 390 390 ... ... @@ -426,6 +426,17 @@ 426 426 [[image:1669021922274-909.png]] 427 427 428 428 436 +== 7.5 Limited of using LA66 as relay of LoRaWAN == 437 + 438 + 439 +LA66 is a LoRa End Node module base on SX1262 core. Use it as relay as mentioned above has below limitation: 440 + 441 +1. It only supports LoRa radio with fix frequency, fix DR (Spreading Factor) , Fix bandwidth and 442 +1. This method only support uplinks. It doesn;t work for LoRaWAN Downlink. 443 +1. Capacity depends on how often the end nodes sends send uplinks. The LA66 needs to spends around 1~~3 seconds to relay one packet ( depends on DR. inlcudes RX and TX time). 444 + 445 + 446 + 429 429 = 8. Technical Support = 430 430 431 431 ... ... @@ -434,6 +434,7 @@ 434 434 * Provide as much information as possible regarding your enquiry (product models, accurately describe your problem and steps to replicate it etc) and send a mail to [[support@dragino.com>>url:file:///D:/市场资料/说明书/LoRa/LG02/support@dragino.com]] 435 435 436 436 455 + 437 437 = 9. Reference = 438 438 439 439
- image-20230718154517-2.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Kilight - Size
-
... ... @@ -1,0 +1,1 @@ 1 +155.8 KB - Content
- image-20230718161437-3.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Kilight - Size
-
... ... @@ -1,0 +1,1 @@ 1 +155.8 KB - Content