Last modified by Xiaoling on 2023/07/24 09:53

From version 33.1
edited by Kilight Cao
on 2022/11/21 17:59
Change comment: There is no comment for this version
To version 36.1
edited by Kilight Cao
on 2023/07/18 16:14
Change comment: Uploaded new attachment "image-20230718161437-3.png", version {1}

Summary

Details

Page properties
Content
... ... @@ -37,6 +37,7 @@
37 37  * Support various network structures
38 38  
39 39  
40 +
40 40  == 1.3 What can you learn from the kit? ==
41 41  
42 42  
... ... @@ -57,6 +57,7 @@
57 57  * Learn different way to connect LoRaWAN network to IoT Server and compare their advantages / disadvantages.
58 58  
59 59  
61 +
60 60  == 1.4 What parts Dragino LoRa IoT v3 includes? ==
61 61  
62 62  
... ... @@ -83,6 +83,7 @@
83 83  * 20 x dupont cable (male to female)
84 84  
85 85  
88 +
86 86  = 2. Example 1: Test a LoRaWAN network =
87 87  
88 88  
... ... @@ -123,21 +123,20 @@
123 123  
124 124  TTN v3 stack has the same configure method as the public TTN server. When user test example 2 here. User need to log in the TTNv3 stack in LPS8v2 as per below:
125 125  
126 -**Input URL( __http:~/~/<hostname>:8080 or http:~/~/<local-IPV4-address> __) in your browser.**
129 +**Input URL( (% style="background-color:yellow" %)//__http:~/~/<hostname>:8080 or http:~/~/<local-IPV4-address>__//(%%)__ __) in your browser.**
127 127  
128 -**Such as  __http:~/~/dragino-54ff12:8080  or http:~/~/<Local-IPV4-Address>__**
131 +**Such as  (% style="background-color:yellow" %)//__http:~/~/dragino-54ff12:8080  or http:~/~/<Local-IPV4-Address>__//(%%)**
129 129  
130 130  
131 131  (% style="color:blue" %)**Login account:**
132 132  
133 -**User ID:  admin**
136 +**User ID:  (% style="background-color:yellow" %)admin(%%)**
134 134  
135 -**Password:  dragino**
138 +**Password:  (% style="background-color:yellow" %)dragino(%%)**
136 136  
137 137  [[image:1669019821266-501.png]]
138 138  
139 139  
140 -
141 141  = 4. Example 3: Test Built-in LoRaWAN server and Application server =
142 142  
143 143  
... ... @@ -207,6 +207,7 @@
207 207  (% style="color:#037691" %)**AT+RXMOD=6,0   ** (%%) ~-~->  Rx Timeout and Reply mode
208 208  )))
209 209  
212 +
210 210  === 5.1.2 Hardware Connection ===
211 211  
212 212  
... ... @@ -343,6 +343,7 @@
343 343  
344 344  
345 345  LA66 USB is loaded with the firmware **[[LA66 USB use LoRaWAN firmware>>url:https://www.dropbox.com/sh/els49fz9rd6fu1y/AAAt-kKIvXu1ZOK0hWysq97na?dl=0]]** and user can use AT Command to set up LA66 with below parameters:
349 +
346 346  (% class="box infomessage" %)
347 347  (((
348 348  (% style="color:#037691" %)**AT+CHS=904100000** (%%) ~-~->  Fix frequency
... ... @@ -353,6 +353,7 @@
353 353  
354 354  (% style="color:#037691" %)**AT+DR=0 ** (%%) ~-~->  Fix DR=0
355 355  )))
360 +
356 356  Set up LA66 USB t work in ABP mode, use fix frequency(904100000) and fix DR0(SF10) to transmit data.
357 357  
358 358  
... ... @@ -360,6 +360,7 @@
360 360  
361 361  
362 362  LA66 Shield is loaded with the firmware **[[LA66 Shield use Point to Point firmware>>url:https://www.dropbox.com/sh/els49fz9rd6fu1y/AAAt-kKIvXu1ZOK0hWysq97na?dl=0]]**, LA66 Shield as Relay needs to be configured as follows:
368 +
363 363  (% class="box infomessage" %)
364 364  (((
365 365  (% style="color:#037691" %)**AT+FRE=904.100,904.100**(%%)  ~-~-> TX and RX frequency set: 904100000 
... ... @@ -385,6 +385,7 @@
385 385  (% style="color:#037691" %)**AT+WAITTIME=1000**(%%)  ~-~-> Relay wait time 1000ms
386 386  )))
387 387  
394 +
388 388  == 7.3 Uplink test ==
389 389  
390 390  
... ... @@ -426,6 +426,17 @@
426 426  [[image:1669021922274-909.png]]
427 427  
428 428  
436 +== 7.5 Limited of using LA66 as relay of LoRaWAN ==
437 +
438 +
439 +LA66 is a LoRa End Node module base on SX1262 core. Use it as relay as mentioned above has below limitation:
440 +
441 +1. It only supports LoRa radio with fix frequency, fix DR (Spreading Factor) , Fix bandwidth and
442 +1. This method only support uplinks. It doesn;t work for LoRaWAN Downlink.
443 +1. Capacity depends on how often the end nodes sends send uplinks. The LA66 needs to spends around 1~~3 seconds to relay one packet ( depends on DR. inlcudes RX and TX time).
444 +
445 +
446 +
429 429  = 8. Technical Support =
430 430  
431 431  
... ... @@ -434,6 +434,7 @@
434 434  * Provide as much information as possible regarding your enquiry (product models, accurately describe your problem and steps to replicate it etc) and send a mail to [[support@dragino.com>>url:file:///D:/市场资料/说明书/LoRa/LG02/support@dragino.com]]
435 435  
436 436  
455 +
437 437  = 9. Reference =
438 438  
439 439  
image-20230718154517-2.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Kilight
Size
... ... @@ -1,0 +1,1 @@
1 +155.8 KB
Content
image-20230718161437-3.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Kilight
Size
... ... @@ -1,0 +1,1 @@
1 +155.8 KB
Content