... ... @@ -249,7 +249,6 @@
249 249  * **Cellular Mode**
250 250  
251 251  
252 -
253 253  == 3.2  Use WAN port to access Internet ==
254 254  
255 255  By default, the DLOS8N is set to use the WAN port to connect to an upstream network. When you connect the DLOS8N’s WAN port to an upstream router, DLOS8N will get an IP address from the router and have Internet access via the upstream router. The network status can be checked in the (% style="color:#4f81bd" %)**home page**:
... ... @@ -366,7 +366,6 @@
366 366  * Legacy V2 Console : (% style="color:red" %)**TTN v2 shuts down in December 2021**
367 367  
368 368  
369 -
370 370  (% style="color:#4f81bd" %)**Step 4: Create a Gateway**
371 371  
372 372  [[image:1652422440891-514.png||height="360" width="747"]]
... ... @@ -408,19 +408,22 @@
408 408  
409 409  (% style="color:red" %)**Note: **The server address must match the Gateway server address you choose in TTN V3.
410 410  
409 +
411 411  In the home page, we can see the LoRaWAN connection is ready now.
412 412  
413 -[[image:1652422685063-596.png||height="327" width="729"]]
412 +[[image:1657014479765-850.png]]
414 414  
414 +
415 415  In TTN v3 portal, we can also see the gateway is connected.
416 416  
417 417  [[image:1652422703020-955.png||height="343" width="730"]]
418 418  
419 419  
420 -== 4.3 Configure frequency ==
420 +== 4.3  Configure frequency ==
421 421  
422 -We also need to set the frequency plan in DLOS8N to match the end node we use, so to receive the LoRaWAN packets from the LoRaWAN sensor.
422 +We also need to set the frequency plan in LG308N to match the end node we use, so to receive the LoRaWAN packets from the LoRaWAN sensor.
423 423  
424 +
424 424  [[image:1652422737399-529.png||height="362" width="737"]]
425 425  
426 426  
... ... @@ -429,7 +429,7 @@
429 429   [[image:1652422763536-750.png||height="514" width="730"]]
430 430  
431 431  
432 -== 4.4 Add a LoRaWAN End Device ==
433 +== 4.4  Add a LoRaWAN End Device ==
433 433  
434 434  (((
435 435  This section shows how to add a LoRaWAN End device to a LoRaWAN network and see the data from TTN web site.
... ... @@ -454,13 +454,18 @@
454 454  * APP Key - Unique key to secure communications with a particular device.
455 455  
456 456  (((
458 +
459 +
457 457  A set of these codes are stored in each device by the manufacturer as the default codes for that particular device. Each device is shipped with a sticker with the default Device EUI as shown below.
458 458  )))
459 459  
460 460  [[image:1652422840936-838.png]]
461 461  
465 +
462 462  (((
463 463  (% style="color:red" %)Note: You may be able to change these codes in a device by using a configuration facility on the device e.g. the LT-22222 uses a serial port access and a series of AT commands.  Changing the codes may be necessary in the case where you have to use codes assigned by a LoRa WAN server.
468 +
469 +
464 464  )))
465 465  
466 466  (((
... ... @@ -471,10 +471,12 @@
471 471  Select **Add Application** to open the screen below.
472 472  )))
473 473  
474 -[[image:1652422946999-255.png||height="356" width="744"]]
480 +[[image:1657014671459-433.png]]
475 475  
482 +
476 476  Open the **Application **select** Add end device**
477 477  
485 +
478 478  Start Register the end device
479 479  
480 480  [[image:1652422975885-591.png||height="359" width="726"]]
... ... @@ -481,6 +481,8 @@
481 481  
482 482  (((
483 483  Select OTAA activation mode
492 +
493 +
484 484  )))
485 485  
486 486  (((
... ... @@ -491,14 +491,18 @@
491 491  
492 492  First, input the End device ID, AppEUI and DevEUI.
493 493  
504 +
494 494  [[image:1652423022781-339.png||height="365" width="741"]]
495 495  
496 496  Secondly, choose the corresponding frequency and LoRaWAN class capabilities.
497 497  
509 +
498 498  [[image:1652423046741-467.png||height="355" width="736"]]
499 499  
500 500  (((
501 501  Finally, Application layer settings input the corresponding AppKey. Before saving the configuration, check that the data matches the device.
514 +
515 +
502 502  )))
503 503  
504 504  (((
... ... @@ -512,18 +512,18 @@
512 512  [[image:1652423277549-324.png||height="273" width="745"]]
513 513  
514 514  
515 -= 5. Web Configure Pages =
529 += 5.  Web Configure Pages =
516 516  
517 -== 5.1 Home ==
531 +== 5.1  Home ==
518 518  
519 519  Shows the system running status.
520 520  
521 -[[image:1652423418568-752.png||height="329" width="724"]]
535 +[[image:1657014949846-507.png]]
522 522  
523 523  
524 -== 5.2 LoRa Settings ==
538 +== 5.2  LoRa Settings ==
525 525  
526 -=== 5.2.1 LoRa ~-~-> LoRa ===
540 +=== 5.2.1  LoRa ~-~-> LoRa ===
527 527  
528 528  (((
529 529  This page shows the LoRa Radio Settings. There are a set of default frequency band according to LoRaWAN protocol, and user can customized the band* as well.
... ... @@ -530,11 +530,11 @@
530 530  )))
531 531  
532 532  (((
533 -Different DLOS8N hardware version can support different frequency range:
547 +Different LG308N hardware version can support different frequency range:
534 534  )))
535 535  
536 -* **868**: valid frequency: 863Mhz ~~ 870Mhz. for bands EU868, RU864, IN865 or KZ865.
537 -* **915**: valid frequency: 902Mhz ~~ 928Mhz. for bands US915, AU915, AS923 or KR920
550 +* (% style="color:blue" %)**868**(%%): valid frequency: 863Mhz ~~ 870Mhz. for bands EU868, RU864, IN865 or KZ865.
551 +* (% style="color:blue" %)**915**(%%): valid frequency: 902Mhz ~~ 928Mhz. for bands US915, AU915, AS923 or KR920
538 538  
539 539  (((
540 540  After user choose the frequency plan, he can see the actually frequency in used by checking the page **LogRead ~-~-> LoRa Log**
1657014949846-507.png