Changes for page LG308N -- LoRaWAN Gateway User Manual
Last modified by Kilight Cao on 2025/02/07 08:57
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 3 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -249,7 +249,6 @@ 249 249 * **Cellular Mode** 250 250 251 251 252 - 253 253 == 3.2 Use WAN port to access Internet == 254 254 255 255 By default, the DLOS8N is set to use the WAN port to connect to an upstream network. When you connect the DLOS8N’s WAN port to an upstream router, DLOS8N will get an IP address from the router and have Internet access via the upstream router. The network status can be checked in the (% style="color:#4f81bd" %)**home page**: ... ... @@ -366,7 +366,6 @@ 366 366 * Legacy V2 Console : (% style="color:red" %)**TTN v2 shuts down in December 2021** 367 367 368 368 369 - 370 370 (% style="color:#4f81bd" %)**Step 4: Create a Gateway** 371 371 372 372 [[image:1652422440891-514.png||height="360" width="747"]] ... ... @@ -377,8 +377,10 @@ 377 377 378 378 [[image:1652422470352-518.png||height="391" width="716"]] 379 379 378 + 380 380 [[image:1652422479876-297.png||height="398" width="729"]] 381 381 381 + 382 382 ((( 383 383 (% style="color:red" %)**Notice: **Gateway Server address must match the gateway configuration, otherwise you will have problem for End Node to join the network. 384 384 ))) ... ... @@ -388,14 +388,14 @@ 388 388 [[image:1652422509034-682.png||height="299" width="739"]] 389 389 390 390 391 -== 4.2 Configure DLOS8N to connect to TTN v3 == 391 +== 4.2 Configure DLOS8N to connect to TTN v3 == 392 392 393 393 ((( 394 -You can now configure the DLOS8N to let it connect to TTN network V3.394 +You can now configure the LG308N to let it connect to TTN network V3. 395 395 ))) 396 396 397 397 ((( 398 -Make sure your DLOS8N has a working Internet Connection first.398 +Make sure your LG308N has a working Internet Connection first. 399 399 ))) 400 400 401 401 ((( ... ... @@ -406,19 +406,22 @@ 406 406 407 407 (% style="color:red" %)**Note: **The server address must match the Gateway server address you choose in TTN V3. 408 408 409 + 409 409 In the home page, we can see the LoRaWAN connection is ready now. 410 410 411 -[[image:165 2422685063-596.png||height="327" width="729"]]412 +[[image:1657014479765-850.png]] 412 412 414 + 413 413 In TTN v3 portal, we can also see the gateway is connected. 414 414 415 415 [[image:1652422703020-955.png||height="343" width="730"]] 416 416 417 417 418 -== 4.3 Configure frequency == 420 +== 4.3 Configure frequency == 419 419 420 -We also need to set the frequency plan in DLOS8N to match the end node we use, so to receive the LoRaWAN packets from the LoRaWAN sensor.422 +We also need to set the frequency plan in LG308N to match the end node we use, so to receive the LoRaWAN packets from the LoRaWAN sensor. 421 421 424 + 422 422 [[image:1652422737399-529.png||height="362" width="737"]] 423 423 424 424 ... ... @@ -427,7 +427,7 @@ 427 427 [[image:1652422763536-750.png||height="514" width="730"]] 428 428 429 429 430 -== 4.4 Add a LoRaWAN End Device == 433 +== 4.4 Add a LoRaWAN End Device == 431 431 432 432 ((( 433 433 This section shows how to add a LoRaWAN End device to a LoRaWAN network and see the data from TTN web site. ... ... @@ -452,13 +452,18 @@ 452 452 * APP Key - Unique key to secure communications with a particular device. 453 453 454 454 ((( 458 + 459 + 455 455 A set of these codes are stored in each device by the manufacturer as the default codes for that particular device. Each device is shipped with a sticker with the default Device EUI as shown below. 456 456 ))) 457 457 458 458 [[image:1652422840936-838.png]] 459 459 465 + 460 460 ((( 461 461 (% style="color:red" %)Note: You may be able to change these codes in a device by using a configuration facility on the device e.g. the LT-22222 uses a serial port access and a series of AT commands. Changing the codes may be necessary in the case where you have to use codes assigned by a LoRa WAN server. 468 + 469 + 462 462 ))) 463 463 464 464 ((( ... ... @@ -469,10 +469,12 @@ 469 469 Select **Add Application** to open the screen below. 470 470 ))) 471 471 472 -[[image:165 2422946999-255.png||height="356" width="744"]]480 +[[image:1657014671459-433.png]] 473 473 482 + 474 474 Open the **Application **select** Add end device** 475 475 485 + 476 476 Start Register the end device 477 477 478 478 [[image:1652422975885-591.png||height="359" width="726"]] ... ... @@ -479,6 +479,8 @@ 479 479 480 480 ((( 481 481 Select OTAA activation mode 492 + 493 + 482 482 ))) 483 483 484 484 ((( ... ... @@ -489,14 +489,18 @@ 489 489 490 490 First, input the End device ID, AppEUI and DevEUI. 491 491 504 + 492 492 [[image:1652423022781-339.png||height="365" width="741"]] 493 493 494 494 Secondly, choose the corresponding frequency and LoRaWAN class capabilities. 495 495 509 + 496 496 [[image:1652423046741-467.png||height="355" width="736"]] 497 497 498 498 ((( 499 499 Finally, Application layer settings input the corresponding AppKey. Before saving the configuration, check that the data matches the device. 514 + 515 + 500 500 ))) 501 501 502 502 ((( ... ... @@ -510,18 +510,18 @@ 510 510 [[image:1652423277549-324.png||height="273" width="745"]] 511 511 512 512 513 -= 5. Web Configure Pages = 529 += 5. Web Configure Pages = 514 514 515 -== 5.1 Home == 531 +== 5.1 Home == 516 516 517 517 Shows the system running status. 518 518 519 -[[image:165 2423418568-752.png||height="329" width="724"]]535 +[[image:1657014949846-507.png]] 520 520 521 521 522 -== 5.2 LoRa Settings == 538 +== 5.2 LoRa Settings == 523 523 524 -=== 5.2.1 LoRa ~-~-> LoRa === 540 +=== 5.2.1 LoRa ~-~-> LoRa === 525 525 526 526 ((( 527 527 This page shows the LoRa Radio Settings. There are a set of default frequency band according to LoRaWAN protocol, and user can customized the band* as well. ... ... @@ -528,11 +528,11 @@ 528 528 ))) 529 529 530 530 ((( 531 -Different DLOS8N hardware version can support different frequency range:547 +Different LG308N hardware version can support different frequency range: 532 532 ))) 533 533 534 -* **868**: valid frequency: 863Mhz ~~ 870Mhz. for bands EU868, RU864, IN865 or KZ865. 535 -* **915**: valid frequency: 902Mhz ~~ 928Mhz. for bands US915, AU915, AS923 or KR920 550 +* (% style="color:blue" %)**868**(%%): valid frequency: 863Mhz ~~ 870Mhz. for bands EU868, RU864, IN865 or KZ865. 551 +* (% style="color:blue" %)**915**(%%): valid frequency: 902Mhz ~~ 928Mhz. for bands US915, AU915, AS923 or KR920 536 536 537 537 ((( 538 538 After user choose the frequency plan, he can see the actually frequency in used by checking the page **LogRead ~-~-> LoRa Log** ... ... @@ -543,9 +543,9 @@ 543 543 Note *: **[[See this instruction for how to customize frequency band>>doc:Main.How to customized LoRaWAN frequency band.WebHome]]** 544 544 545 545 546 -=== 5.2.2 LoRa ~-~-> ABP Decryption === 562 +=== 5.2.2 LoRa ~-~-> ABP Decryption === 547 547 548 -The DLOS8N can communicate with LoRaWAN ABP End Node without the need of LoRaWAN server. It can be used in some cases such as:564 +The LG308N can communicate with LoRaWAN ABP End Node without the need of LoRaWAN server. It can be used in some cases such as: 549 549 550 550 * No internet connection. 551 551 * User wants to get data forward in gateway and forward to their server based on MQTT/HTTP, etc. (Combine ABP communication method and [[MQTT forward together>>doc:Main.MQTT Forward Instruction.WebHome]]).
- 1657014479765-850.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Xiaoling - Size
-
... ... @@ -1,0 +1,1 @@ 1 +169.5 KB - Content
- 1657014671459-433.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Xiaoling - Size
-
... ... @@ -1,0 +1,1 @@ 1 +43.2 KB - Content
- 1657014949846-507.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Xiaoling - Size
-
... ... @@ -1,0 +1,1 @@ 1 +169.0 KB - Content