Changes for page Update Firmware for the AI Sensors
Last modified by Karry Zhuang on 2024/09/20 17:17
From version 34.1
edited by Karry Zhuang
on 2024/04/24 14:59
on 2024/04/24 14:59
Change comment:
Uploaded new attachment "image-20240424145937-3.png", version {1}
Summary
-
Page properties (2 modified, 0 added, 0 removed)
-
Attachments (0 modified, 1 added, 0 removed)
Details
- Page properties
-
- Author
-
... ... @@ -1,1 +1,1 @@ 1 -XWiki. karry1 +XWiki.Xiaoling - Content
-
... ... @@ -1,17 +1,38 @@ 1 + 2 + 3 + 4 +**Table of Contents:** 5 + 6 +{{toc/}} 7 + 8 + 9 + 10 + 11 + 12 + 13 + 1 1 = 1. Prepare Hardware & Software = 2 2 3 -* Update Tool:OTA_Tool 4 -* Hardware: Sensor, Converter 5 -* Firmware: 6 6 17 +* Update Tool:[[OTA_Tool>>https://www.dropbox.com/scl/fi/d0tephd9ttghwf1ednj2s/OTA_Tool.rar?rlkey=sll5ny1fikqc8l0se9c4egxzs&st=f3ml8mop&dl=0]] 18 +* Hardware: AIS Sensor, AUC USB TTL Adapter for AIS Sensors, PC 19 +* Firmware:[[Digital wheel dial firmware>>https://www.dropbox.com/scl/fi/nxa0nw0k2qhbpcxzfsz03/Digital-table-wheel-firmware.rar?rlkey=u9wqmilfwu899fhc9i2jfcwou&st=ftsl46f5&dl=0]],[[Pointer dial firmware>>https://www.dropbox.com/scl/fi/y03feisk7ztq1ey6pmhqb/Pointer-dial-firmware.rar?rlkey=knlx67m1g26xukrthcum1kk23&st=5m196s89&dl=0]] 20 + 21 + 22 + 7 7 = 2. Hardware Connection = 8 8 9 -The data cable should be connected to the AIS (note: there is no camera on this side), while the computer should be connected on the other side. 10 10 26 +The AIS Sensors and AUC USB TTL Adapter for AIS Sensors are connected and then connected to the PC. 27 + 28 +[[image:image-20240428155042-1.png||height="598" width="506"]] 29 + 11 11 [[image:image-20240424145824-1.gif]][[image:image-20240424145847-2.jpeg||height="359" width="478"]] 12 12 32 + 13 13 = 3.OTA UART flash = 14 14 35 + 15 15 Open the OTA_Tool folder and put the latest firmware "layout.bin" and "output. img" into the img folder. 16 16 17 17 [[image:1713510920220-760.png||height="219" width="816"]] ... ... @@ -26,23 +26,28 @@ 26 26 27 27 2 Select an upgrade mode. AIS supports serial port upgrade only. Press 2 to select Uart protocol 28 28 29 -3 Select a port number. Choosethe largestumberof serialport,For example, hereshows16 and 17.50 +3 Select a port number.The instance device port number is 17.Press 1 to select COM17 30 30 31 31 4 Select the baud rate. The default baud rate is 921600. Press 14 to select 921600 32 32 33 33 [[image:1713511914316-181.png||height="754" width="865"]] 55 + 56 + 34 34 After the baud rate is configured, the upgrade page is displayed. 1 is to check whether the communication port is correct. 35 35 36 36 [[image:1713513351848-254.png||height="477" width="861"]]x 37 37 61 + 38 38 Select 1 to check whether the configured port is correct. 39 39 40 40 [[image:1713513373484-487.png||height="472" width="856"]] 41 41 66 + 42 42 Select 2 is port is after normal communication with AIS. 43 43 44 44 [[image:1713513478607-793.png||height="471" width="851"]] 45 45 71 + 46 46 Press 0, press Enter, and select 2 to go to the upgrade surface. 47 47 48 48 [[image:1713513522820-547.png||height="467" width="847"]] ... ... @@ -49,6 +49,7 @@ 49 49 50 50 [[image:1713513544122-175.png||height="467" width="845"]] 51 51 78 + 52 52 Select 2 to enter the upgrade. 53 53 54 54 [[image:1713513668777-698.png||height="464" width="840"]]
- image-20240428155042-1.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.karry - Size
-
... ... @@ -1,0 +1,1 @@ 1 +3.1 MB - Content