7
8
Edwin Chen 15.1 9 = 1. LoRaST v4 base Hardware =
Edwin Chen 1.1 10
Xiaoling 15.2 11
Edwin Chen 29.1 12 Below hardware use LoRaST v4 module. They supports UART Access for AT Command and Firmware Upgrade.
Edwin Chen 1.1 13
Xiaoling 26.22 14 {{velocity}}
15 $xwiki.ssfx.use("js/xwiki/table/table.css")
16 $xwiki.jsfx.use("js/xwiki/table/tablefilterNsort.js", true)
17 {{/velocity}}
Xiaoling 26.13 18
Edwin Chen 29.1 19 (% border="1" cellspacing="5" class="doOddEven filterable grid sortable" id="tableid" style="width:829px" %)
20 |(% style="background-color:#d9e2f3; width:290px" %)**Models**|(% style="background-color:#d9e2f3; color:#0070c0; width:172px" %)**Mother Board**|(% style="background-color:#d9e2f3; color:#0070c0; width:116px" %)**UART for AT Commands**|(% style="background-color:#d9e2f3; color:#0070c0; width:248px" %)**UART for Upgrade Firmware**
21 |(% style="width:290px" %)PS-LB, PS-LB-NA, SDI12-LB|(% style="width:172px" %)SIB|(% style="width:116px" %)Instruction|(% style="width:248px" %)Instruction
22 |(% style="width:290px" %)(((
23 SN50v3, S31-LB, S31B-LB,
Xiaoling 26.13 24
Edwin Chen 29.1 25 D20-LB.D20S-LB, D21-LB, D22-LB
26 )))|(% style="width:172px" %)SN50v3|(% style="width:116px" %) |(% style="width:248px" %)
27 |(% style="width:290px" %)LHT65N|(% style="width:172px" %)LHT65N|(% style="width:116px" %) |(% style="width:248px" %)
28 |(% style="width:290px" %) |(% style="width:172px" %) |(% style="width:116px" %) |(% style="width:248px" %)
Xiaoling 26.24 29
Edwin Chen 15.1 30 = 2. UART for AT Commands =
31
32 == 2.1 Generate software set up for AT Commands via UART ==
33
Xiaoling 15.2 34
Xiaoling 26.25 35 ~1. Use a general serial tool.
Edwin Chen 9.1 36
Xiaoling 26.25 37 2. Connect PC to device's UART interface
38
39 3. Set up serial tool with : BaudRate: 9600, databit:8, No parity, No flow control.
40
41 (((
42 4. The password is the last six characters of APPSKEY or PIN of box
43
Xiaoling 20.2 44 **Example:**
Bei Jinggeng 16.1 45
46 APPSKEY= 41 85 71 A7 5D 7E 54 52 25 58 74 85 96 14 74 85
47
48 The password:147485
Bei Jinggeng 19.1 49
Bei Jinggeng 20.1 50 [[image:image-20230329162900-1.png||height="302" width="648"]]
Bei Jinggeng 19.1 51
52
Bei Jinggeng 16.1 53 )))
54
Edwin Chen 9.1 55 [[image:image-20221224170218-1.png||height="497" width="640"]]
56
57
Edwin Chen 15.1 58 == 2.2 UART Connection for SIB mother board ==
Edwin Chen 9.1 59
Xiaoling 15.3 60
Edwin Chen 9.1 61 [[image:image-20221224171304-3.png||height="545" width="863"]]
62
63
Edwin Chen 21.1 64 == 2.3 UART Connection for SN50v3 base mother board ==
65
Edwin Chen 34.1 66 [[image:image-20230515102801-1.png]]
Edwin Chen 21.1 67
Xiaoling 26.24 68
Edwin Chen 15.1 69 = 3. UART for Firmware Upgrade =
Edwin Chen 9.1 70
Edwin Chen 28.1 71 == 3.1 Check Your device already have bootloader ==
Edwin Chen 13.1 72
Edwin Chen 28.1 73 === 3.1.1 What is Dragino Bootloader? ===
Edwin Chen 24.1 74
Xiaoling 26.24 75
Edwin Chen 24.1 76 Dragino Bootloader is a customizer made bootloader which support below features:
77
Edwin Chen 36.1 78 * OTA Update via LoRa
79 * OTA Batch update configure via LoRa
Edwin Chen 24.1 80
Edwin Chen 31.1 81 All Dragino End Devices base on LoRa ST v4 supports Dragino Bootloader.
Edwin Chen 24.1 82
83
Edwin Chen 28.1 84 === 3.1.2 How can i know if my device already have bootloader? ===
Xiaoling 26.26 85
Edwin Chen 28.1 86 If a device has a bootloader. it will output bootloader info to UART when boot. As below:
Xiaoling 15.3 87
Edwin Chen 28.1 88 [[image:image-20230514150410-1.png||height="398" width="815"]]
Edwin Chen 22.1 89
Edwin Chen 23.1 90
Edwin Chen 28.1 91 === 3.1.3 How to upload bootloader to device? ===
Edwin Chen 23.1 92
Edwin Chen 32.1 93 If your is LoRa ST v4 base hardware and doesn't have bootloader. You can upload a bootloader to it.
Edwin Chen 23.1 94
Edwin Chen 36.1 95 **[[Downlink Link for OTA bootloader>>https://www.dropbox.com/sh/g4cp2lm85ovr8hu/AADX-4aEE-7SuKQAKTWrgKHIa?dl=0]].**
Edwin Chen 23.1 96
Edwin Chen 36.1 97
98 **Update a firmware via TremoProgrammer:**
99
100 LoRaSTv4 Base hardware support UART update firmware. the UART connection is the same as AT Command connection, with the need for two extra action. See below for the steps:
101
102 (% style="color:blue" %)**Step1**(%%): Set BOOT Switch to (% style="color:blue" %)**PROG**(%%) mode. PROG mode is for update firmware specially.
103
104 (% style="color:blue" %)**Step2**(%%): Press (% style="color:blue" %)**Reset**(%%) button, the module will then boot into program mode.
105
106 (% style="color:blue" %)**Step3**(%%): Use (% style="color:blue" %)**TremoProgrammer**(%%) to update the firmware to LoRaST v4.
107
108 (% style="color:blue" %)**Step4**(%%): Set BOOT Switch to (% style="color:blue" %)**FLASH**(%%) position. Press Reset button again and module will run the new software.
109
110
111 Below is the method for how to update via (% style="color:blue" %)**TremoProgrammer:**
112
113 1.  **TremoProgrammer** download link:  [[https:~~/~~/www.dropbox.com/sh/j0qyc7a9ejit7jk/AACtx2tK4gEv6YFXMIVUM4dLa?dl=0>>url:https://www.dropbox.com/sh/j0qyc7a9ejit7jk/AACtx2tK4gEv6YFXMIVUM4dLa?dl=0]]
114
115 2.  Run** (% style="color:blue" %)TremoProgrammer.(%%)**
116
117 3.  Choose software and set the address to (% style="color:blue" %)**0x08000000**(%%).
118
119 4. Rember to set BOOT Switch to (% style="color:blue" %)**FLASH**(%%) after update finish. And you should be about to see Bootloader info in output after update
120
121 [[image:image-20230515171651-1.png]]
122
123
124
Edwin Chen 28.1 125 == 3.2 Update Firmware (Assume the device already have a bootloader) ==
126
Edwin Chen 42.1 127 === 3.2.1 Update a firmware via Dragino Sensor Manager Utility.exe ===
Edwin Chen 28.1 128
Edwin Chen 42.1 129 ~1. Download **[[OTA Tool>>https://www.dropbox.com/sh/bqepfzvusv6ig8e/AACKB4J9pdY1I7s5kcKfCUGHa?dl=0]]**
Edwin Chen 28.1 130
Edwin Chen 42.1 131 2. Use below schedule to update:
Edwin Chen 44.1 132 (% style="color:red" %)**FLASH**(%%)
Edwin Chen 28.1 133
Edwin Chen 42.1 134 [[image:image-20230520100249-1.png||height="483" width="805"]]
Edwin Chen 28.1 135
Edwin Chen 42.1 136 [[image:image-20230520100405-3.png||height="295" width="804"]]
Edwin Chen 28.1 137
Edwin Chen 42.1 138 [[image:image-20230520100541-5.png||height="535" width="799"]]
139
140
141 = 4. FAQ =
142
143 == 4.1 How to recover if upgrade wrong file to bootloader? ==
144
145 You can just upload the bootloader again.
146
147
148 == 4.2 How to recover if upgrade wrong firmware via Dragino Sensor Manager Utility.exe? ==
149
150 The UART upgrade via Dragino Sensor Manager Utility.exe is base on Dragino Bootloader. So if you are able to upgrade some file via this tool. It means the device has bootloder.
151
152
153 The upgrade via Dragino Sensor Manager Utility is base on firmware level and won't effect the bootloader. If you upgrade a wrong firmware file, you can try below:
154
155 ~1. UART upgrade via Dragino Sensor Manager Utility again to the correct version. The password should use the AT PIN for the wrong firmware.  (This method is not 100% work, depends which wrong firmware you have upgraded)
156
Edwin Chen 43.1 157 2. Use **TremoProgrammer **to update firmware. [[Insturction>>||anchor="H4.3HowtouseTremoProgrammertoupdatefirmwareifthereisbootloaderinthedevice3F"]]
Edwin Chen 42.1 158
159 3. Use **[[OTA update>>http://wiki.dragino.com/xwiki/bin/view/Main/Firmware%20OTA%20Update%20for%20Sensors/]]**, this is base on Bootloader so it will work. Make you choose the correct frequency band (base on the firmware version in the sensor or use EU868 which is the default setting.)
160
161
162 == 4.3 How to use TremoProgrammer to update firmware if there is bootloader in the device? ==
163
164 Make sure your device already bootloader while use this update. Otherwise device won't be able to boot ( can be solve by upload a bootloader to the device).
165
Edwin Chen 13.1 166 LoRaSTv4 Base hardware support UART update firmware. the UART connection is the same as AT Command connection, with the need for two extra action. See below for the steps:
167
Edwin Chen 42.1 168 **Step1**: Set BOOT Switch to **PROG** mode. PROG mode is for update firmware specially.
Edwin Chen 13.1 169
Edwin Chen 42.1 170 **Step2**: Press **Reset** button, the module will then boot into program mode.
Edwin Chen 13.1 171
Edwin Chen 42.1 172 **Step3**: Use **TremoProgrammer** to update the firmware to LoRaST v4.
Edwin Chen 13.1 173
Edwin Chen 42.1 174 **Step4**: Set BOOT Switch to **FLASH** position. Press Reset button again and module will run the new software.
Edwin Chen 13.1 175
Edwin Chen 42.1 176 Below is the method for how to update via **TremoProgrammer:**
Edwin Chen 13.1 177
178 1.  Software download link:  [[https:~~/~~/www.dropbox.com/sh/j0qyc7a9ejit7jk/AACtx2tK4gEv6YFXMIVUM4dLa?dl=0>>url:https://www.dropbox.com/sh/j0qyc7a9ejit7jk/AACtx2tK4gEv6YFXMIVUM4dLa?dl=0]]
179
Edwin Chen 42.1 180 2.  Run** TremoProgrammer.**
Edwin Chen 13.1 181
Edwin Chen 42.1 182 3.  Choose software and set the address to **0x0800D000**. (% class="mark" %)VERY IMPORTANT for this address(%%).
Edwin Chen 13.1 183
Edwin Chen 42.1 184 4. Rember to set BOOT Switch to **FLASH** after update
Edwin Chen 13.1 185
Edwin Chen 42.1 186 [[image:http://wiki.dragino.com/xwiki/bin/download/Main/UART%20Access%20for%20LoRa%20ST%20v4%20base%20model/WebHome/image-20221224174341-4.png?width=374&height=471&rev=1.1||alt="image-20221224174341-4.png" height="471" width="374"]]