Version 14.1 by Edwin Chen on 2022/12/24 17:47

Hide last authors
Edwin Chen 14.1 1
2
3 **Table of Contents:**
4
5 {{toc/}}
6
7
8
9
10
Edwin Chen 1.1 11 = LoRaST v4 base Hardware =
12
13 Below hardware use LoRaST v4 module. They module support UART Access for AT Command and Firmware Upgrade.
14
Edwin Chen 3.1 15 (% border="1" cellspacing="10" class="doOddEven filterable grid sortable" id="tableid" style="background-color:#f7faff; width:770px" %)
16 (% class="sortHeader" %)|=(% style="width: 180px;" %)Model|=(% style="width: 135px;" %)Mother Board|=(% style="width: 199px;" %)UART for AT Commands|=(% style="width: 230px;" %)UART for Upgrade Firmware
Edwin Chen 1.1 17 |(% style="width:180px" %)(((
Edwin Chen 3.1 18 **PS-LB **
Edwin Chen 4.1 19 )))|(% style="width:135px" %)SIB|(% style="width:199px" %)Instruction|(% style="width:230px" %)Instruction
Edwin Chen 5.1 20
Edwin Chen 9.1 21 = UART for AT Commands =
Edwin Chen 5.1 22
Edwin Chen 9.1 23 == Generate software set up for AT Commands via UART ==
Edwin Chen 5.1 24
Edwin Chen 9.1 25 1. Use a general serial tool.
26 1. Connect PC to device's UART interface
27 1. Set up serial tool with : BaudRate: 9600, databit:8, No parity, No flow control.
28
29 [[image:image-20221224170218-1.png||height="497" width="640"]]
30
31
32 == UART Connection for SIB mother board ==
33
34 [[image:image-20221224171304-3.png||height="545" width="863"]]
35
36
37
38 = UART for Firmware Upgrade =
39
Edwin Chen 13.1 40 == General Instruction for UART update firmware ==
41
42 LoRaSTv4 Base hardware support UART update firmware. the UART connection is the same as AT Command connection, with the need for two extra action. See below for the steps:
43
44 **Step1**: Set BOOT Switch to **PROG** mode. PROG mode is for update firmware specially.
45
46 **Step2**: Press **Reset** button, the module will then boot into program mode.
47
48 **Step3**: Use **TremoProgrammer** to update the firmware to LoRaST v4.
49
50 **Step4**: Set BOOT Switch to **FLASH** position. Press Reset button again and module will run the new software.
51
52
53 Below is the method for how to update via **TremoProgrammer:**
54
55 1.  Software download link:  [[https:~~/~~/www.dropbox.com/sh/j0qyc7a9ejit7jk/AACtx2tK4gEv6YFXMIVUM4dLa?dl=0>>url:https://www.dropbox.com/sh/j0qyc7a9ejit7jk/AACtx2tK4gEv6YFXMIVUM4dLa?dl=0]]
56
Edwin Chen 14.1 57 2.  Run** TremoProgrammer.**
Edwin Chen 13.1 58
59 3.  Choose software and set the address to **0x0800D000**
60
61 4. Rember to set BOOT Switch to FLASH after update
62
63 [[image:image-20221224174341-4.png||height="471" width="374"]]
64
65
66 == UART Connection for SIB mother board for Program. ==
67
68 Below shows the SIB board UART connection, reset button and BOOT Switch (Program Jumper) position. They can be used for firmware upgrade reference.
69
70 [[image:image-20221224174605-6.png||height="569" width="880"]]
71