Changes for page UART Access for LoRa ST v4 base model
Last modified by Mengting Qiu on 2024/11/11 17:09
Change comment:
There is no comment for this version
Summary
-
Page properties (2 modified, 0 added, 0 removed)
-
Attachments (0 modified, 0 added, 3 removed)
Details
- Page properties
-
- Author
-
... ... @@ -1,1 +1,1 @@ 1 -XWiki.E llie1 +XWiki.Edwin - Content
-
... ... @@ -11,34 +11,25 @@ 11 11 12 12 Below hardware use LoRaST v4 module. They supports UART Access for AT Command and Firmware Upgrade. 13 13 14 - 15 15 {{velocity}} 16 16 $xwiki.ssfx.use("js/xwiki/table/table.css") 17 17 $xwiki.jsfx.use("js/xwiki/table/tablefilterNsort.js", true) 18 18 {{/velocity}} 19 19 20 -(% border="1" cellspacing="5" class="doOddEven filterable grid sortable" id="tableid" style=" background-color:#f2f2f2;width:869px" %)21 - (% class="sortHeader" %)|=(% style="width: 269px;background-color:rgb(217, 226, 243);" %)Models|=(% style="width: 158px;background-color: rgb(217,226, 243);" %)**Mother Board**|=(% style="width: 214px;background-color: rgb(217,226, 243);" %)**UART for AT Commands**|=(% style="width: 226px;background-color: rgb(217,226, 243);" %)**UART for Upgrade Firmware**22 -|(% style="width:2 69px" %)PS-LB, PS-LB-NA, SDI12-LB|(% style="width:158px" %)SIB|(% style="width:214px" %)Instruction|(% style="width:226px" %)Instruction23 -|(% style="width:2 69px" %)(((19 +(% border="1" cellspacing="5" class="doOddEven filterable grid sortable" id="tableid" style="width:829px" %) 20 +|(% style="background-color:#d9e2f3; width:290px" %)**Models**|(% style="background-color:#d9e2f3; color:#0070c0; width:172px" %)**Mother Board**|(% style="background-color:#d9e2f3; color:#0070c0; width:116px" %)**UART for AT Commands**|(% style="background-color:#d9e2f3; color:#0070c0; width:248px" %)**UART for Upgrade Firmware** 21 +|(% style="width:290px" %)PS-LB, PS-LB-NA, SDI12-LB|(% style="width:172px" %)SIB|(% style="width:116px" %)Instruction|(% style="width:248px" %)Instruction 22 +|(% style="width:290px" %)((( 24 24 SN50v3, S31-LB, S31B-LB, 25 25 26 26 D20-LB.D20S-LB, D21-LB, D22-LB 27 -)))|(% style="width:158px" %)SN50v3|(% style="width:214px" %) |(% style="width:226px" %) 28 -|(% style="width:269px" %)LHT65N|(% style="width:158px" %)LHT65N|(% style="width:214px" %) |(% style="width:226px" %) 29 -|(% style="width:269px" %)((( 30 -RS485-LB, SE01-LB, SPH01-LB, 26 +)))|(% style="width:172px" %)SN50v3|(% style="width:116px" %) |(% style="width:248px" %) 27 +|(% style="width:290px" %)LHT65N|(% style="width:172px" %)LHT65N|(% style="width:116px" %) |(% style="width:248px" %) 28 +|(% style="width:290px" %) |(% style="width:172px" %) |(% style="width:116px" %) |(% style="width:248px" %) 31 31 32 -LMS01-LB,LDS12-LB,LDS40-LB, 33 - 34 -DDS75-LB,DDS45-LB,DDS04-LB, 35 - 36 -DDS20-LB,MDS120-LB,MDS200-LB, WSC2-LB 37 -)))|(% style="width:158px" %)RS485-BL|(% style="width:214px" %) |(% style="width:226px" %) 38 - 39 39 = 2. UART for AT Commands = 40 40 41 -== 2.1 Genera lsoftware set up for AT Commands via UART ==32 +== 2.1 Generate software set up for AT Commands via UART == 42 42 43 43 44 44 ~1. Use a general serial tool. ... ... @@ -50,7 +50,6 @@ 50 50 ((( 51 51 4. The password is the last six characters of APPSKEY or PIN of box 52 52 53 - 54 54 **Example:** 55 55 56 56 APPSKEY= 41 85 71 A7 5D 7E 54 52 25 58 74 85 96 14 74 85 ... ... @@ -73,16 +73,9 @@ 73 73 74 74 == 2.3 UART Connection for SN50v3 base mother board == 75 75 66 +[[image:image-20230515102801-1.png]] 76 76 77 -[[image:image-20230515102801-1.png||height="635" width="860"]] 78 78 79 - 80 -== 2.4 UART Connection for RS485-BL base mother board == 81 - 82 - 83 -[[image:微信图片_20230809144604.jpg||height="673" width="791"]] 84 - 85 - 86 86 = 3. UART for Firmware Upgrade = 87 87 88 88 == 3.1 Check Your device already have bootloader == ... ... @@ -100,7 +100,6 @@ 100 100 101 101 === 3.1.2 How can i know if my device already have bootloader? === 102 102 103 - 104 104 If a device has a bootloader. it will output bootloader info to UART when boot. As below: 105 105 106 106 [[image:image-20230514150410-1.png||height="398" width="815"]] ... ... @@ -108,13 +108,12 @@ 108 108 109 109 === 3.1.3 How to upload bootloader to device? === 110 110 111 - 112 112 If your is LoRa ST v4 base hardware and doesn't have bootloader. You can upload a bootloader to it. 113 113 114 114 **[[Downlink Link for OTA bootloader>>https://www.dropbox.com/sh/g4cp2lm85ovr8hu/AADX-4aEE-7SuKQAKTWrgKHIa?dl=0]].** 115 115 116 116 117 - (% style="color:blue" %)**Update a firmware via TremoProgrammer:**98 +**Update a firmware via TremoProgrammer:** 118 118 119 119 LoRaSTv4 Base hardware support UART update firmware. the UART connection is the same as AT Command connection, with the need for two extra action. See below for the steps: 120 120 ... ... @@ -140,22 +140,19 @@ 140 140 [[image:image-20230515171651-1.png]] 141 141 142 142 124 + 143 143 == 3.2 Update Firmware (Assume the device already have a bootloader) == 144 144 145 - 146 -Video Instruction: **[[https:~~/~~/youtu.be/G_xEZnNjJmM >>https://youtu.be/G_xEZnNjJmM]]** 147 - 148 - 149 149 === 3.2.1 Update a firmware via Dragino Sensor Manager Utility.exe === 150 150 151 - 152 152 ~1. Download **[[OTA Tool>>https://www.dropbox.com/sh/bqepfzvusv6ig8e/AACKB4J9pdY1I7s5kcKfCUGHa?dl=0]]** 153 153 154 154 2. Use below schedule to update: 132 +(% style="color:red" %)**FLASH**(%%) 155 155 156 -[[image:image-2023052 6105151-1.png]]134 +[[image:image-20230520100249-1.png||height="483" width="805"]] 157 157 158 -[[image:image-2023052 6105910-2.png]]136 +[[image:image-20230520100405-3.png||height="295" width="804"]] 159 159 160 160 [[image:image-20230520100541-5.png||height="535" width="799"]] 161 161 ... ... @@ -164,13 +164,11 @@ 164 164 165 165 == 4.1 How to recover if upgrade wrong file to bootloader? == 166 166 167 - 168 168 You can just upload the bootloader again. 169 169 170 170 171 171 == 4.2 How to recover if upgrade wrong firmware via Dragino Sensor Manager Utility.exe? == 172 172 173 - 174 174 The UART upgrade via Dragino Sensor Manager Utility.exe is base on Dragino Bootloader. So if you are able to upgrade some file via this tool. It means the device has bootloder. 175 175 176 176 ... ... @@ -185,29 +185,27 @@ 185 185 186 186 == 4.3 How to use TremoProgrammer to update firmware if there is bootloader in the device? == 187 187 188 - 189 189 Make sure your device already bootloader while use this update. Otherwise device won't be able to boot ( can be solve by upload a bootloader to the device). 190 190 191 191 LoRaSTv4 Base hardware support UART update firmware. the UART connection is the same as AT Command connection, with the need for two extra action. See below for the steps: 192 192 193 - (% style="color:blue" %)**Step1**(%%): Set BOOT Switch to(% style="color:blue" %)**PROG**(%%)mode. PROG mode is for update firmware specially.168 + **Step1**: Set BOOT Switch to **PROG** mode. PROG mode is for update firmware specially. 194 194 195 - (%style="color:blue" %)**Step2**(%%): Press(% style="color:blue" %)**Reset**(%%)button, the module will then boot into program mode.170 + **Step2**: Press **Reset** button, the module will then boot into program mode. 196 196 197 - (% style="color:blue" %)**Step3**(%%): Use(% style="color:blue" %)**TremoProgrammer**(%%)to update the firmware to LoRaST v4.172 + **Step3**: Use **TremoProgrammer** to update the firmware to LoRaST v4. 198 198 199 - (% style="color:blue" %)**Step4**(%%): Set BOOT Switch to(% style="color:blue" %)**FLASH**(%%)position. Press Reset button again and module will run the new software.174 + **Step4**: Set BOOT Switch to **FLASH** position. Press Reset button again and module will run the new software. 200 200 176 +Below is the method for how to update via **TremoProgrammer:** 201 201 202 -Below is the method for how to update via (% style="color:blue" %)**TremoProgrammer:** 203 - 204 204 1. Software download link: [[https:~~/~~/www.dropbox.com/sh/j0qyc7a9ejit7jk/AACtx2tK4gEv6YFXMIVUM4dLa?dl=0>>url:https://www.dropbox.com/sh/j0qyc7a9ejit7jk/AACtx2tK4gEv6YFXMIVUM4dLa?dl=0]] 205 205 206 -2. Run (% style="color:blue" %)** TremoProgrammer.**180 +2. Run** TremoProgrammer.** 207 207 208 -3. Choose software and set the address to (% style="color:blue" %)**0x0800D000**. (%style="color:red" %)**VERY IMPORTANT for this address**.182 +3. Choose software and set the address to **0x0800D000**. (% class="mark" %)VERY IMPORTANT for this address(%%). 209 209 210 -4. Rember to set BOOT Switch to (% style="color:blue" %)**FLASH**(%%)after update184 +4. Rember to set BOOT Switch to **FLASH** after update 211 211 212 212 [[image:http://wiki.dragino.com/xwiki/bin/download/Main/UART%20Access%20for%20LoRa%20ST%20v4%20base%20model/WebHome/image-20221224174341-4.png?width=374&height=471&rev=1.1||alt="image-20221224174341-4.png" height="471" width="374"]] 213 213
- image-20230526105151-1.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Edwin - Size
-
... ... @@ -1,1 +1,0 @@ 1 -31.0 KB - Content
- image-20230526105910-2.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Edwin - Size
-
... ... @@ -1,1 +1,0 @@ 1 -41.3 KB - Content
- 微信图片_20230809144604.jpg
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Ellie - Size
-
... ... @@ -1,1 +1,0 @@ 1 -914.9 KB - Content