<
From version < 43.1 >
edited by Edwin Chen
on 2023/05/20 10:26
To version < 47.6 >
edited by Xiaoling
on 2023/06/01 16:00
>
Change comment: There is no comment for this version

Summary

Details

Page properties
Author
... ... @@ -1,1 +1,1 @@
1 -XWiki.Edwin
1 +XWiki.Xiaoling
Content
... ... @@ -16,17 +16,17 @@
16 16  $xwiki.jsfx.use("js/xwiki/table/tablefilterNsort.js", true)
17 17  {{/velocity}}
18 18  
19 -(% border="1" cellspacing="5" class="doOddEven filterable grid sortable" id="tableid" style="width:829px" %)
20 -|(% style="background-color:#d9e2f3; width:290px" %)**Models**|(% style="background-color:#d9e2f3; color:#0070c0; width:172px" %)**Mother Board**|(% style="background-color:#d9e2f3; color:#0070c0; width:116px" %)**UART for AT Commands**|(% style="background-color:#d9e2f3; color:#0070c0; width:248px" %)**UART for Upgrade Firmware**
21 -|(% style="width:290px" %)PS-LB, PS-LB-NA, SDI12-LB|(% style="width:172px" %)SIB|(% style="width:116px" %)Instruction|(% style="width:248px" %)Instruction
19 +(% border="1" cellspacing="5" class="doOddEven filterable grid sortable" id="tableid" style="width:949px" %)
20 +|(% style="background-color:#d9e2f3; color:#0070c0; width:290px" %)**Models**|(% style="background-color:#d9e2f3; color:#0070c0; width:172px" %)**Mother Board**|(% style="background-color:#d9e2f3; color:#0070c0; width:233px" %)**UART for AT Commands**|(% style="background-color:#d9e2f3; color:#0070c0; width:249px" %)**UART for Upgrade Firmware**
21 +|(% style="width:290px" %)PS-LB, PS-LB-NA, SDI12-LB|(% style="width:172px" %)SIB|(% style="width:233px" %)Instruction|(% style="width:249px" %)Instruction
22 22  |(% style="width:290px" %)(((
23 23  SN50v3, S31-LB, S31B-LB,
24 24  
25 25  D20-LB.D20S-LB, D21-LB, D22-LB
26 -)))|(% style="width:172px" %)SN50v3|(% style="width:116px" %) |(% style="width:248px" %)
27 -|(% style="width:290px" %)LHT65N|(% style="width:172px" %)LHT65N|(% style="width:116px" %) |(% style="width:248px" %)
28 -|(% style="width:290px" %) |(% style="width:172px" %) |(% style="width:116px" %) |(% style="width:248px" %)
26 +)))|(% style="width:172px" %)SN50v3|(% style="width:233px" %) |(% style="width:249px" %)
27 +|(% style="width:290px" %)LHT65N|(% style="width:172px" %)LHT65N|(% style="width:233px" %) |(% style="width:249px" %)
29 29  
29 +
30 30  = 2. UART for AT Commands =
31 31  
32 32  == 2.1 Generate software set up for AT Commands via UART ==
... ... @@ -41,6 +41,7 @@
41 41  (((
42 42  4. The password is the last six characters of APPSKEY or PIN of box
43 43  
44 +
44 44  **Example:**
45 45  
46 46  APPSKEY= 41 85 71 A7 5D 7E 54 52 25 58 74 85 96 14 74 85
... ... @@ -63,6 +63,7 @@
63 63  
64 64  == 2.3 UART Connection for SN50v3 base mother board ==
65 65  
67 +
66 66  [[image:image-20230515102801-1.png]]
67 67  
68 68  
... ... @@ -83,6 +83,7 @@
83 83  
84 84  === 3.1.2 How can i know if my device already have bootloader? ===
85 85  
88 +
86 86  If a device has a bootloader. it will output bootloader info to UART when boot. As below:
87 87  
88 88  [[image:image-20230514150410-1.png||height="398" width="815"]]
... ... @@ -90,12 +90,13 @@
90 90  
91 91  === 3.1.3 How to upload bootloader to device? ===
92 92  
96 +
93 93  If your is LoRa ST v4 base hardware and doesn't have bootloader. You can upload a bootloader to it.
94 94  
95 95  **[[Downlink Link for OTA bootloader>>https://www.dropbox.com/sh/g4cp2lm85ovr8hu/AADX-4aEE-7SuKQAKTWrgKHIa?dl=0]].**
96 96  
97 97  
98 -**Update a firmware via TremoProgrammer:**
102 +(% style="color:blue" %)**Update a firmware via TremoProgrammer:**
99 99  
100 100  LoRaSTv4 Base hardware support UART update firmware. the UART connection is the same as AT Command connection, with the need for two extra action. See below for the steps:
101 101  
... ... @@ -121,20 +121,19 @@
121 121  [[image:image-20230515171651-1.png]]
122 122  
123 123  
124 -
125 125  == 3.2 Update Firmware (Assume the device already have a bootloader) ==
126 126  
127 127  === 3.2.1 Update a firmware via Dragino Sensor Manager Utility.exe ===
128 128  
132 +
129 129  ~1. Download **[[OTA Tool>>https://www.dropbox.com/sh/bqepfzvusv6ig8e/AACKB4J9pdY1I7s5kcKfCUGHa?dl=0]]**
130 130  
131 131  2. Use below schedule to update:
132 132  
133 -[[image:image-20230520100249-1.png||height="483" width="805"]]
137 +[[image:image-20230526105151-1.png]]
134 134  
135 -[[image:image-20230520100405-3.png||height="295" width="804"]]
139 +[[image:image-20230526105910-2.png]]
136 136  
137 -
138 138  [[image:image-20230520100541-5.png||height="535" width="799"]]
139 139  
140 140  
... ... @@ -142,11 +142,13 @@
142 142  
143 143  == 4.1 How to recover if upgrade wrong file to bootloader? ==
144 144  
148 +
145 145  You can just upload the bootloader again.
146 146  
147 147  
148 148  == 4.2 How to recover if upgrade wrong firmware via Dragino Sensor Manager Utility.exe? ==
149 149  
154 +
150 150  The UART upgrade via Dragino Sensor Manager Utility.exe is base on Dragino Bootloader. So if you are able to upgrade some file via this tool. It means the device has bootloder.
151 151  
152 152  
... ... @@ -161,27 +161,29 @@
161 161  
162 162  == 4.3 How to use TremoProgrammer to update firmware if there is bootloader in the device? ==
163 163  
169 +
164 164  Make sure your device already bootloader while use this update. Otherwise device won't be able to boot ( can be solve by upload a bootloader to the device).
165 165  
166 166  LoRaSTv4 Base hardware support UART update firmware. the UART connection is the same as AT Command connection, with the need for two extra action. See below for the steps:
167 167  
168 - **Step1**: Set BOOT Switch to **PROG** mode. PROG mode is for update firmware specially.
174 + (% style="color:blue" %)**Step1**(%%): Set BOOT Switch to (% style="color:blue" %)**PROG**(%%) mode. PROG mode is for update firmware specially.
169 169  
170 - **Step2**: Press **Reset** button, the module will then boot into program mode.
176 + (% style="color:blue" %) **Step2**(%%): Press (% style="color:blue" %)**Reset**(%%) button, the module will then boot into program mode.
171 171  
172 - **Step3**: Use **TremoProgrammer** to update the firmware to LoRaST v4.
178 + (% style="color:blue" %)**Step3**(%%): Use (% style="color:blue" %)**TremoProgrammer**(%%) to update the firmware to LoRaST v4.
173 173  
174 - **Step4**: Set BOOT Switch to **FLASH** position. Press Reset button again and module will run the new software.
180 + (% style="color:blue" %)**Step4**(%%): Set BOOT Switch to (% style="color:blue" %)**FLASH**(%%) position. Press Reset button again and module will run the new software.
175 175  
176 -Below is the method for how to update via **TremoProgrammer:**
177 177  
183 +Below is the method for how to update via (% style="color:blue" %)**TremoProgrammer:**
184 +
178 178  1.  Software download link:  [[https:~~/~~/www.dropbox.com/sh/j0qyc7a9ejit7jk/AACtx2tK4gEv6YFXMIVUM4dLa?dl=0>>url:https://www.dropbox.com/sh/j0qyc7a9ejit7jk/AACtx2tK4gEv6YFXMIVUM4dLa?dl=0]]
179 179  
180 -2.  Run** TremoProgrammer.**
187 +2.  Run(% style="color:blue" %)** TremoProgrammer.**
181 181  
182 -3.  Choose software and set the address to **0x0800D000**. (% class="mark" %)VERY IMPORTANT for this address(%%).
189 +3.  Choose software and set the address to (% style="color:blue" %)**0x0800D000**. (% style="color:red" %)**VERY IMPORTANT for this address**.
183 183  
184 -4. Rember to set BOOT Switch to **FLASH** after update
191 +4. Rember to set BOOT Switch to (% style="color:blue" %)**FLASH**(%%) after update
185 185  
186 186  [[image:http://wiki.dragino.com/xwiki/bin/download/Main/UART%20Access%20for%20LoRa%20ST%20v4%20base%20model/WebHome/image-20221224174341-4.png?width=374&height=471&rev=1.1||alt="image-20221224174341-4.png" height="471" width="374"]]
187 187  
image-20230526105151-1.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Edwin
Size
... ... @@ -1,0 +1,1 @@
1 +31.0 KB
Content
image-20230526105910-2.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Edwin
Size
... ... @@ -1,0 +1,1 @@
1 +41.3 KB
Content
Copyright ©2010-2022 Dragino Technology Co., LTD. All rights reserved
Dragino Wiki v2.0