Changes for page UART Access for LoRa ST v4 base model
Last modified by Mengting Qiu on 2024/11/11 17:09
Change comment:
There is no comment for this version
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 9 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -63,6 +63,7 @@ 63 63 64 64 == 2.3 UART Connection for SN50v3 base mother board == 65 65 66 +[[image:image-20230515102801-1.png]] 66 66 67 67 68 68 = 3. UART for Firmware Upgrade = ... ... @@ -74,9 +74,10 @@ 74 74 75 75 Dragino Bootloader is a customizer made bootloader which support below features: 76 76 77 -* OTA Update via LoRa or BLE78 -* OTA Batch update configure via LoRa or BLE78 +* OTA Update via LoRa 79 +* OTA Batch update configure via LoRa 79 79 81 +All Dragino End Devices base on LoRa ST v4 supports Dragino Bootloader. 80 80 81 81 82 82 === 3.1.2 How can i know if my device already have bootloader? === ... ... @@ -88,19 +88,13 @@ 88 88 89 89 === 3.1.3 How to upload bootloader to device? === 90 90 93 +If your is LoRa ST v4 base hardware and doesn't have bootloader. You can upload a bootloader to it. 91 91 95 +**[[Downlink Link for OTA bootloader>>https://www.dropbox.com/sh/g4cp2lm85ovr8hu/AADX-4aEE-7SuKQAKTWrgKHIa?dl=0]].** 92 92 93 -== 3.2 Update Firmware (Assume the device already have a bootloader) == 94 94 95 - === 3.2.1Update a firmware viaDraginobootloader===98 +**Update a firmware via TremoProgrammer:** 96 96 97 - 98 - 99 - 100 -=== 3.2.2 Update a firmware via TremoProgrammer === 101 - 102 -Make sure your device already bootloader while use this update. Other device won't be able to boot ( can be solve by upload a bootloader to the device). 103 - 104 104 LoRaSTv4 Base hardware support UART update firmware. the UART connection is the same as AT Command connection, with the need for two extra action. See below for the steps: 105 105 106 106 (% style="color:blue" %)**Step1**(%%): Set BOOT Switch to (% style="color:blue" %)**PROG**(%%) mode. PROG mode is for update firmware specially. ... ... @@ -114,15 +114,77 @@ 114 114 115 115 Below is the method for how to update via (% style="color:blue" %)**TremoProgrammer:** 116 116 117 -1. Software download link: [[https:~~/~~/www.dropbox.com/sh/j0qyc7a9ejit7jk/AACtx2tK4gEv6YFXMIVUM4dLa?dl=0>>url:https://www.dropbox.com/sh/j0qyc7a9ejit7jk/AACtx2tK4gEv6YFXMIVUM4dLa?dl=0]]113 +1. **TremoProgrammer** download link: [[https:~~/~~/www.dropbox.com/sh/j0qyc7a9ejit7jk/AACtx2tK4gEv6YFXMIVUM4dLa?dl=0>>url:https://www.dropbox.com/sh/j0qyc7a9ejit7jk/AACtx2tK4gEv6YFXMIVUM4dLa?dl=0]] 118 118 119 119 2. Run** (% style="color:blue" %)TremoProgrammer.(%%)** 120 120 121 -3. Choose software and set the address to (% style="color:blue" %)**0x0800 D000**(%%).(% style="color:red" %)VERY IMPORTANT: USE THIS ADDRESS FOR FIRMWARE WITHOUT BOOTLOADER117 +3. Choose software and set the address to (% style="color:blue" %)**0x08000000**(%%). 122 122 123 -4. Rember to set BOOT Switch to (% style="color:blue" %)**FLASH**(%%) after update 119 +4. Rember to set BOOT Switch to (% style="color:blue" %)**FLASH**(%%) after update finish. And you should be about to see Bootloader info in output after update 124 124 125 -[[image:image-202 21224174341-4.png||height="471" width="374"]]121 +[[image:image-20230515171651-1.png]] 126 126 127 127 128 - 124 + 125 +== 3.2 Update Firmware (Assume the device already have a bootloader) == 126 + 127 +=== 3.2.1 Update a firmware via Dragino Sensor Manager Utility.exe === 128 + 129 +~1. Download **[[OTA Tool>>https://www.dropbox.com/sh/bqepfzvusv6ig8e/AACKB4J9pdY1I7s5kcKfCUGHa?dl=0]]** 130 + 131 +2. Use below schedule to update: 132 + 133 +[[image:image-20230526105151-1.png]] 134 + 135 +[[image:image-20230526105910-2.png]] 136 + 137 +[[image:image-20230520100541-5.png||height="535" width="799"]] 138 + 139 + 140 += 4. FAQ = 141 + 142 +== 4.1 How to recover if upgrade wrong file to bootloader? == 143 + 144 +You can just upload the bootloader again. 145 + 146 + 147 +== 4.2 How to recover if upgrade wrong firmware via Dragino Sensor Manager Utility.exe? == 148 + 149 +The UART upgrade via Dragino Sensor Manager Utility.exe is base on Dragino Bootloader. So if you are able to upgrade some file via this tool. It means the device has bootloder. 150 + 151 + 152 +The upgrade via Dragino Sensor Manager Utility is base on firmware level and won't effect the bootloader. If you upgrade a wrong firmware file, you can try below: 153 + 154 +~1. UART upgrade via Dragino Sensor Manager Utility again to the correct version. The password should use the AT PIN for the wrong firmware. (This method is not 100% work, depends which wrong firmware you have upgraded) 155 + 156 +2. Use **TremoProgrammer **to update firmware. [[Insturction>>||anchor="H4.3HowtouseTremoProgrammertoupdatefirmwareifthereisbootloaderinthedevice3F"]] 157 + 158 +3. Use **[[OTA update>>http://wiki.dragino.com/xwiki/bin/view/Main/Firmware%20OTA%20Update%20for%20Sensors/]]**, this is base on Bootloader so it will work. Make you choose the correct frequency band (base on the firmware version in the sensor or use EU868 which is the default setting.) 159 + 160 + 161 +== 4.3 How to use TremoProgrammer to update firmware if there is bootloader in the device? == 162 + 163 +Make sure your device already bootloader while use this update. Otherwise device won't be able to boot ( can be solve by upload a bootloader to the device). 164 + 165 +LoRaSTv4 Base hardware support UART update firmware. the UART connection is the same as AT Command connection, with the need for two extra action. See below for the steps: 166 + 167 + **Step1**: Set BOOT Switch to **PROG** mode. PROG mode is for update firmware specially. 168 + 169 + **Step2**: Press **Reset** button, the module will then boot into program mode. 170 + 171 + **Step3**: Use **TremoProgrammer** to update the firmware to LoRaST v4. 172 + 173 + **Step4**: Set BOOT Switch to **FLASH** position. Press Reset button again and module will run the new software. 174 + 175 +Below is the method for how to update via **TremoProgrammer:** 176 + 177 +1. Software download link: [[https:~~/~~/www.dropbox.com/sh/j0qyc7a9ejit7jk/AACtx2tK4gEv6YFXMIVUM4dLa?dl=0>>url:https://www.dropbox.com/sh/j0qyc7a9ejit7jk/AACtx2tK4gEv6YFXMIVUM4dLa?dl=0]] 178 + 179 +2. Run** TremoProgrammer.** 180 + 181 +3. Choose software and set the address to **0x0800D000**. (% class="mark" %)VERY IMPORTANT for this address(%%). 182 + 183 +4. Rember to set BOOT Switch to **FLASH** after update 184 + 185 +[[image:http://wiki.dragino.com/xwiki/bin/download/Main/UART%20Access%20for%20LoRa%20ST%20v4%20base%20model/WebHome/image-20221224174341-4.png?width=374&height=471&rev=1.1||alt="image-20221224174341-4.png" height="471" width="374"]] 186 +
- image-20230515102801-1.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Edwin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +812.6 KB - Content
- image-20230515171651-1.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Edwin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +20.6 KB - Content
- image-20230520100249-1.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Edwin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +38.5 KB - Content
- image-20230520100330-2.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Edwin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +28.0 KB - Content
- image-20230520100405-3.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Edwin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +58.3 KB - Content
- image-20230520100449-4.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Edwin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +107.8 KB - Content
- image-20230520100541-5.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Edwin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +92.3 KB - Content
- image-20230526105151-1.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Edwin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +31.0 KB - Content
- image-20230526105910-2.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Edwin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +41.3 KB - Content