Changes for page UART Access for LoRa ST v4 base model
Last modified by Mengting Qiu on 2024/11/11 17:09
Change comment:
There is no comment for this version
Summary
-
Page properties (2 modified, 0 added, 0 removed)
-
Attachments (0 modified, 0 added, 1 removed)
Details
- Page properties
-
- Author
-
... ... @@ -1,1 +1,1 @@ 1 -XWiki. Edwin1 +XWiki.Xiaoling - Content
-
... ... @@ -16,25 +16,22 @@ 16 16 $xwiki.jsfx.use("js/xwiki/table/tablefilterNsort.js", true) 17 17 {{/velocity}} 18 18 19 -(% border="1" cellspacing="5" class="doOddEven filterable grid sortable" id="tableid" style="width: 800.222px" %)20 -| (% style="background-color:#d9e2f3; width:151px" %)**Models**|(% style="background-color:#d9e2f3; color:#0070c0; width:159px" %)**Mother Board**|(% style="background-color:#d9e2f3; color:#0070c0; width:252px" %)**UART for AT Commands**|(% style="background-color:#d9e2f3; color:#0070c0; width:234px" %)**UART for Upgrade Firmware**21 -| (%style="width:151px" %)PS-LB|(%style="width:159px" %)SIB|(%style="width:252px" %)Instruction|(%style="width:234px" %)Instruction19 +(% border="1" cellspacing="5" class="doOddEven filterable grid sortable" id="tableid" style="width:500px" %) 20 +|Models|Mother Board|UART for AT Commands|UART for Upgrade Firmware 21 +| | | | 22 22 23 - 24 24 = 2. UART for AT Commands = 25 25 26 26 == 2.1 Generate software set up for AT Commands via UART == 27 27 28 28 29 -~1. Use a general serial tool. 28 +(% start="1" style="list-style-type:decimal" %) 29 +1. Use a general serial tool. 30 +1. Connect PC to device's UART interface 31 +1. Set up serial tool with : BaudRate: 9600, databit:8, No parity, No flow control. 32 +1. ((( 33 +The password is the last six characters of APPSKEY or PIN of box 30 30 31 -2. Connect PC to device's UART interface 32 - 33 -3. Set up serial tool with : BaudRate: 9600, databit:8, No parity, No flow control. 34 - 35 -((( 36 -4. The password is the last six characters of APPSKEY or PIN of box 37 - 38 38 **Example:** 39 39 40 40 APPSKEY= 41 85 71 A7 5D 7E 54 52 25 58 74 85 96 14 74 85 ... ... @@ -58,21 +58,20 @@ 58 58 == 2.3 UART Connection for SN50v3 base mother board == 59 59 60 60 61 - 62 62 = 3. UART for Firmware Upgrade = 63 63 64 -== 3.1 Check Yourdevicealreadyhave bootloader==60 +== 3.1 Update firmware == 65 65 66 -=== 3.1. 1What is Dragino Bootloader? ===62 +=== 3.1.0 What is Dragino Bootloader? === 67 67 68 - 69 69 Dragino Bootloader is a customizer made bootloader which support below features: 70 70 71 71 * OTA Update via LoRa or BLE 72 72 * OTA Batch update configure via LoRa or BLE 73 73 74 -(% border="1" cellspacing="5" style="width:912.222px" %) 75 -|(% style="background-color:#d9e2f3; color:#0070c0; width:429px" %)**Model with LoRa Bootloader**|(% style="background-color:#d9e2f3; color:#0070c0; width:480px" %)**Model with BLE Bootloader** 69 + 70 +(% border="1" cellspacing="5" style="width:912.222px;style="background-color:f2f2f2" %) 71 +|(% style="width:429px;background-color:#D9E2F3;color:#0070C0 " %)**Model with LoRa Bootloader**|(% style="width:480px;background-color:#D9E2F3;color:#0070C0 " %)**Model with BLE Bootloader** 76 76 |(% style="width:429px" %)((( 77 77 PS-LB, SDI12-LB, PS-LB-NA, SN50v3-LB, 78 78 ... ... @@ -79,29 +79,15 @@ 79 79 D2x-LB, S31x-LB, SDI12-LB 80 80 )))|(% style="width:480px" %) 81 81 78 +=== 3.1.1 Update a firmware with Dragino bootloader === 82 82 83 -=== 3.1.2 How can i know if my device already have bootloader? === 84 84 85 -If a device has a bootloader. it will output bootloader info to UART when boot. As below: 86 86 87 -[[image:image-20230514150410-1.png||height="398" width="815"]] 88 88 83 +=== 3.1.2 Update a firmware without bootloader === 89 89 90 - ===3.1.3Howto upload bootloadertodevice?===85 +If a firmware's name doesn't have the suffix **_with_bootloader**. It means the firmware is without bootloader and user can use this method to uplink. 91 91 92 - 93 - 94 -== 3.2 Update Firmware (Assume the device already have a bootloader) == 95 - 96 -=== 3.2.1 Update a firmware via Dragino bootloader === 97 - 98 - 99 - 100 - 101 -=== 3.2.2 Update a firmware via TremoProgrammer === 102 - 103 -Make sure your device already bootloader while use this update. Other device won't be able to boot ( can be solve by upload a bootloader to the device). 104 - 105 105 LoRaSTv4 Base hardware support UART update firmware. the UART connection is the same as AT Command connection, with the need for two extra action. See below for the steps: 106 106 107 107 (% style="color:blue" %)**Step1**(%%): Set BOOT Switch to (% style="color:blue" %)**PROG**(%%) mode. PROG mode is for update firmware specially. ... ... @@ -126,4 +126,13 @@ 126 126 [[image:image-20221224174341-4.png||height="471" width="374"]] 127 127 128 128 129 - 111 + 112 + 113 + 114 + 115 +== 3.2 UART Connection for SIB mother board for Program. == 116 + 117 + 118 +Below shows the SIB board UART connection, reset button and BOOT Switch (Program Jumper) position. They can be used for firmware upgrade reference. 119 + 120 +[[image:image-20221224174605-6.png||height="569" width="880"]]
- image-20230514150410-1.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Edwin - Size
-
... ... @@ -1,1 +1,0 @@ 1 -275.3 KB - Content