Changes for page UART Access for LoRa ST v4 base model
Last modified by Mengting Qiu on 2024/11/11 17:09
Change comment:
There is no comment for this version
Summary
-
Page properties (2 modified, 0 added, 0 removed)
Details
- Page properties
-
- Author
-
... ... @@ -1,1 +1,1 @@ 1 -XWiki. Xiaoling1 +XWiki.Bei - Content
-
... ... @@ -10,18 +10,13 @@ 10 10 11 11 12 12 Below hardware use LoRaST v4 module. They module support UART Access for AT Command and Firmware Upgrade. 13 +{{velocity}}$xwiki.ssfx.use("js/xwiki/table/table.css") 14 +$xwiki.jsfx.use("js/xwiki/table/tablefilterNsort.js", true){{/velocity}} 13 13 14 -{{velocity}} 15 -$xwiki.ssfx.use("js/xwiki/table/table.css") 16 -$xwiki.jsfx.use("js/xwiki/table/tablefilterNsort.js", true) 17 -{{/velocity}} 18 - 19 - 20 - 21 -(% border="1" cellspacing="5" class="doOddEven filterable grid sortable" id="tableid" style="background-color:#f7faff; width:621.989px" %) 16 +(% border="1" cellspacing="10" class="doOddEven filterable grid sortable" id="tableid" style="background-color:#f7faff; width:621.989px" %) 22 22 (% class="sortHeader" %)|=(% style="width: 77px;" %)Model|=(% style="width: 120px;" %)Mother Board|=(% style="width: 199px;" %)UART for AT Commands|=(% style="width: 221px;" %)UART for Upgrade Firmware 23 23 |(% style="width:77px" %)((( 24 -PS-LB 19 +**PS-LB ** 25 25 )))|(% style="width:120px" %)SIB|(% style="width:199px" %)Instruction|(% style="width:221px" %)Instruction 26 26 27 27 = 2. UART for AT Commands = ... ... @@ -36,13 +36,13 @@ 36 36 1. ((( 37 37 The password is the last six characters of APPSKEY or PIN of box 38 38 39 - **Example:**34 +Example: 40 40 41 41 APPSKEY= 41 85 71 A7 5D 7E 54 52 25 58 74 85 96 14 74 85 42 42 43 43 The password:147485 44 44 45 -[[image:image-20230329162900-1.png||height="302" width="648"]] 40 +[[image:https://qiye.aliyun.com/attachment/downloadex?ri=%2Falimail%2FinternalLinks%2FrefreshToken&o=1&et=normal&ext=png&e=jinggeng.bei%40dragino.cc&f=3e538434-66e4-4c2a-abd3-d6a69fd04ec6&m=2_0%3ADzzzzyPr-xZ%24---.S1oEkZQ&n=image013.png]][[image:image-20230329162900-1.png||height="302" width="648"]] 46 46 47 47 48 48 ))) ... ... @@ -56,42 +56,11 @@ 56 56 [[image:image-20221224171304-3.png||height="545" width="863"]] 57 57 58 58 59 -== 2.3 UART Connection for SN50v3 base mother board == 60 - 61 - 62 62 = 3. UART for Firmware Upgrade = 63 63 64 -== 3.1 Update firmware == 56 +== 3.1 General Instruction for UART update firmware == 65 65 66 -=== 3.1.0 What is Dragino Bootloader? === 67 67 68 -Dragino Bootloader is a customizer made bootloader which support below features: 69 - 70 -* OTA Update via LoRa or BLE 71 -* OTA Batch update configure via LoRa or BLE 72 - 73 -{{velocity}} 74 -$xwiki.ssfx.use("js/xwiki/table/table.css") 75 -$xwiki.jsfx.use("js/xwiki/table/tablefilterNsort.js", true) 76 -{{/velocity}} 77 - 78 -(% border="1" cellspacing="10" class="doOddEven filterable grid sortable" id="tableid" style="background-color:#f7faff; width:621.989px" %) 79 -(% class="sortHeader" %)|=(% style="width: 307px;" %)Model with LoRa Bootloader|=(% style="width: 313px;" %)Model with BLE Bootloader 80 -|(% style="width:307px" %)((( 81 -PS-LB, SDI12-LB, PS-LB-NA, SN50v3-LB, 82 - 83 -D2x-LB, S31x-LB, SDI12-LB 84 -)))|(% style="width:313px" %) 85 - 86 -=== 3.1.1 Update a firmware with Dragino bootloader === 87 - 88 - 89 - 90 - 91 -=== 3.1.2 Update a firmware without bootloader === 92 - 93 -If a firmware's name doesn't have the suffix **_with_bootloader**. It means the firmware is without bootloader and user can use this method to uplink. 94 - 95 95 LoRaSTv4 Base hardware support UART update firmware. the UART connection is the same as AT Command connection, with the need for two extra action. See below for the steps: 96 96 97 97 (% style="color:blue" %)**Step1**(%%): Set BOOT Switch to (% style="color:blue" %)**PROG**(%%) mode. PROG mode is for update firmware specially. ... ... @@ -109,7 +109,7 @@ 109 109 110 110 2. Run** (% style="color:blue" %)TremoProgrammer.(%%)** 111 111 112 -3. Choose software and set the address to (% style="color:blue" %)**0x0800D000** (%%). (% style="color:red" %)VERY IMPORTANT: USE THIS ADDRESS FOR FIRMWARE WITHOUT BOOTLOADER76 +3. Choose software and set the address to (% style="color:blue" %)**0x0800D000** 113 113 114 114 4. Rember to set BOOT Switch to (% style="color:blue" %)**FLASH**(%%) after update 115 115 ... ... @@ -116,10 +116,6 @@ 116 116 [[image:image-20221224174341-4.png||height="471" width="374"]] 117 117 118 118 119 - 120 - 121 - 122 - 123 123 == 3.2 UART Connection for SIB mother board for Program. == 124 124 125 125