From version < 26.29 >
edited by Xiaoling
on 2023/04/20 12:00
To version < 22.1 >
edited by Edwin Chen
on 2023/04/17 23:40
>
Change comment: There is no comment for this version

Summary

Details

Page properties
Author
... ... @@ -1,1 +1,1 @@
1 -XWiki.Xiaoling
1 +XWiki.Edwin
Content
... ... @@ -1,4 +2,3 @@
1 -(% class="wikigeneratedid" %)
2 2  **Table of Contents:**
3 3  
4 4  {{toc/}}
... ... @@ -6,36 +6,32 @@
6 6  
7 7  
8 8  
8 +
9 9  = 1. LoRaST v4 base Hardware =
10 10  
11 11  
12 12  Below hardware use LoRaST v4 module. They module support UART Access for AT Command and Firmware Upgrade.
13 +{{velocity}}$xwiki.ssfx.use("js/xwiki/table/table.css")
14 +$xwiki.jsfx.use("js/xwiki/table/tablefilterNsort.js", true){{/velocity}}
13 13  
14 -{{velocity}}
15 -$xwiki.ssfx.use("js/xwiki/table/table.css")
16 -$xwiki.jsfx.use("js/xwiki/table/tablefilterNsort.js", true)
17 -{{/velocity}}
16 +(% border="1" cellspacing="10" class="doOddEven filterable grid sortable" id="tableid" style="background-color:#f7faff; width:621.989px" %)
17 +(% class="sortHeader" %)|=(% style="width: 77px;" %)Model|=(% style="width: 120px;" %)Mother Board|=(% style="width: 199px;" %)UART for AT Commands|=(% style="width: 221px;" %)UART for Upgrade Firmware
18 +|(% style="width:77px" %)(((
19 +PS-LB
20 +)))|(% style="width:120px" %)SIB|(% style="width:199px" %)Instruction|(% style="width:221px" %)Instruction
18 18  
19 -(% border="1" cellspacing="5" class="doOddEven filterable grid sortable" id="tableid" style="width:800.222px" %)
20 -|(% style="background-color:#d9e2f3; width:151px" %)**Models**|(% style="background-color:#d9e2f3; color:#0070c0; width:159px" %)**Mother Board**|(% style="background-color:#d9e2f3; color:#0070c0; width:252px" %)**UART for AT Commands**|(% style="background-color:#d9e2f3; color:#0070c0; width:234px" %)**UART for Upgrade Firmware**
21 -|(% style="width:151px" %)PS-LB|(% style="width:159px" %)SIB|(% style="width:252px" %)Instruction|(% style="width:234px" %)Instruction
22 -
23 -
24 -
25 25  = 2. UART for AT Commands =
26 26  
27 27  == 2.1 Generate software set up for AT Commands via UART ==
28 28  
29 29  
30 -~1. Use a general serial tool.
27 +(% start="1" style="list-style-type:decimal" %)
28 +1. Use a general serial tool.
29 +1. Connect PC to device's UART interface
30 +1. Set up serial tool with : BaudRate: 9600, databit:8, No parity, No flow control.
31 +1. (((
32 +The password is the last six characters of APPSKEY or PIN of box
31 31  
32 -2. Connect PC to device's UART interface
33 -
34 -3. Set up serial tool with : BaudRate: 9600, databit:8, No parity, No flow control.
35 -
36 -(((
37 -4. The password is the last six characters of APPSKEY or PIN of box
38 -
39 39  **Example:**
40 40  
41 41  APPSKEY= 41 85 71 A7 5D 7E 54 52 25 58 74 85 96 14 74 85
... ... @@ -59,38 +59,13 @@
59 59  == 2.3 UART Connection for SN50v3 base mother board ==
60 60  
61 61  
62 -
63 63  = 3. UART for Firmware Upgrade =
64 64  
65 65  == 3.1 Update firmware ==
66 66  
67 -=== 3.1.0 What is Dragino Bootloader? ===
61 +=== 3.1.1 Update a firmware without bootloader ===
68 68  
69 69  
70 -Dragino Bootloader is a customizer made bootloader which support below features:
71 -
72 -* OTA Update via LoRa or BLE
73 -* OTA Batch update configure via LoRa or BLE
74 -
75 -(% border="1" cellspacing="5" style="width:912.222px" %)
76 -|(% style="background-color:#d9e2f3; color:#0070c0; width:429px" %)**Model with LoRa Bootloader**|(% style="background-color:#d9e2f3; color:#0070c0; width:480px" %)**Model with BLE Bootloader**
77 -|(% style="width:429px" %)(((
78 -PS-LB, SDI12-LB, PS-LB-NA, SN50v3-LB,
79 -
80 -D2x-LB, S31x-LB, SDI12-LB
81 -)))|(% style="width:480px" %)
82 -
83 -
84 -
85 -=== 3.1.1 Update a firmware with Dragino bootloader ===
86 -
87 -
88 -
89 -
90 -=== 3.1.2 Update a firmware without bootloader ===
91 -
92 -If a firmware's name doesn't have the suffix **_with_bootloader**. It means the firmware is without bootloader and user can use this method to uplink.
93 -
94 94  LoRaSTv4 Base hardware support UART update firmware. the UART connection is the same as AT Command connection, with the need for two extra action. See below for the steps:
95 95  
96 96   (% style="color:blue" %)**Step1**(%%): Set BOOT Switch to (% style="color:blue" %)**PROG**(%%) mode. PROG mode is for update firmware specially.
... ... @@ -108,7 +108,7 @@
108 108  
109 109  2.  Run** (% style="color:blue" %)TremoProgrammer.(%%)**
110 110  
111 -3.  Choose software and set the address to (% style="color:blue" %)**0x0800D000**(%%). (% style="color:red" %)VERY IMPORTANT: USE THIS ADDRESS FOR FIRMWARE WITHOUT BOOTLOADER
81 +3.  Choose software and set the address to (% style="color:blue" %)**0x0800D000(%%)**. (% style="color:red" %)VERY IMPORTANT: USE THIS ADDRESS FOR FIRMWARE WITHOUT BOOTLOADER(%%)
112 112  
113 113  4. Rember to set BOOT Switch to (% style="color:blue" %)**FLASH**(%%) after update
114 114  
... ... @@ -121,3 +121,6 @@
121 121  Below shows the SIB board UART connection, reset button and BOOT Switch (Program Jumper) position. They can be used for firmware upgrade reference.
122 122  
123 123  [[image:image-20221224174605-6.png||height="569" width="880"]]
94 +
95 +
96 +
Copyright ©2010-2022 Dragino Technology Co., LTD. All rights reserved
Dragino Wiki v2.0