<
From version < 26.23 >
edited by Xiaoling
on 2023/04/20 11:26
To version < 28.1 >
edited by Edwin Chen
on 2023/05/14 15:16
>
Change comment: There is no comment for this version

Summary

Details

Page properties
Author
... ... @@ -1,1 +1,1 @@
1 -XWiki.Xiaoling
1 +XWiki.Edwin
Content
... ... @@ -16,22 +16,25 @@
16 16  $xwiki.jsfx.use("js/xwiki/table/tablefilterNsort.js", true)
17 17  {{/velocity}}
18 18  
19 -(% border="1" cellspacing="5" class="doOddEven filterable grid sortable" id="tableid" style="width:500px" %)
20 -|Models|Mother Board|UART for AT Commands|UART for Upgrade Firmware
21 -| | | |
19 +(% border="1" cellspacing="5" class="doOddEven filterable grid sortable" id="tableid" style="width:800.222px" %)
20 +|(% style="background-color:#d9e2f3; width:151px" %)**Models**|(% style="background-color:#d9e2f3; color:#0070c0; width:159px" %)**Mother Board**|(% style="background-color:#d9e2f3; color:#0070c0; width:252px" %)**UART for AT Commands**|(% style="background-color:#d9e2f3; color:#0070c0; width:234px" %)**UART for Upgrade Firmware**
21 +|(% style="width:151px" %)PS-LB|(% style="width:159px" %)SIB|(% style="width:252px" %)Instruction|(% style="width:234px" %)Instruction
22 22  
23 +
23 23  = 2. UART for AT Commands =
24 24  
25 25  == 2.1 Generate software set up for AT Commands via UART ==
26 26  
27 27  
28 -(% start="1" style="list-style-type:decimal" %)
29 -1. Use a general serial tool.
30 -1. Connect PC to device's UART interface
31 -1. Set up serial tool with : BaudRate: 9600, databit:8, No parity, No flow control.
32 -1. (((
33 -The password is the last six characters of APPSKEY or PIN of box
29 +~1. Use a general serial tool.
34 34  
31 +2. Connect PC to device's UART interface
32 +
33 +3. Set up serial tool with : BaudRate: 9600, databit:8, No parity, No flow control.
34 +
35 +(((
36 +4. The password is the last six characters of APPSKEY or PIN of box
37 +
35 35  **Example:**
36 36  
37 37  APPSKEY= 41 85 71 A7 5D 7E 54 52 25 58 74 85 96 14 74 85
... ... @@ -55,20 +55,21 @@
55 55  == 2.3 UART Connection for SN50v3 base mother board ==
56 56  
57 57  
61 +
58 58  = 3. UART for Firmware Upgrade =
59 59  
60 -== 3.1 Update firmware ==
64 +== 3.1 Check Your device already have bootloader ==
61 61  
62 -=== 3.1.0 What is Dragino Bootloader? ===
66 +=== 3.1.1 What is Dragino Bootloader? ===
63 63  
68 +
64 64  Dragino Bootloader is a customizer made bootloader which support below features:
65 65  
66 66  * OTA Update via LoRa or BLE
67 67  * OTA Batch update configure via LoRa or BLE
68 68  
69 -
70 -(% border="1" cellspacing="5" style="width:912.222px;style="background-color:f2f2f2" %)
71 -|(% style="width:429px;background-color:#D9E2F3;color:#0070C0 " %)**Model with LoRa Bootloader**|(% style="width:480px;background-color:#D9E2F3;color:#0070C0 " %)**Model with BLE Bootloader**
74 +(% border="1" cellspacing="5" style="width:912.222px" %)
75 +|(% style="background-color:#d9e2f3; color:#0070c0; width:429px" %)**Model with LoRa Bootloader**|(% style="background-color:#d9e2f3; color:#0070c0; width:480px" %)**Model with BLE Bootloader**
72 72  |(% style="width:429px" %)(((
73 73  PS-LB, SDI12-LB, PS-LB-NA, SN50v3-LB,
74 74  
... ... @@ -75,15 +75,29 @@
75 75  D2x-LB, S31x-LB, SDI12-LB
76 76  )))|(% style="width:480px" %)
77 77  
78 -=== 3.1.1 Update a firmware with Dragino bootloader ===
79 79  
83 +=== 3.1.2 How can i know if my device already have bootloader? ===
80 80  
85 +If a device has a bootloader. it will output bootloader info to UART when boot. As below:
81 81  
87 +[[image:image-20230514150410-1.png||height="398" width="815"]]
82 82  
83 -=== 3.1.2 Update a firmware without bootloader ===
84 84  
85 -If a firmware's name doesn't have the suffix **_with_bootloader**. It means the firmware is without bootloader and user can use this method to uplink.
90 +=== 3.1.3 How to upload bootloader to device? ===
86 86  
92 +
93 +
94 +== 3.2 Update Firmware (Assume the device already have a bootloader) ==
95 +
96 +=== 3.2.1 Update a firmware via Dragino bootloader ===
97 +
98 +
99 +
100 +
101 +=== 3.2.2 Update a firmware via TremoProgrammer ===
102 +
103 +Make sure your device already bootloader while use this update. Other device won't be able to boot ( can be solve by upload a bootloader to the device).
104 +
87 87  LoRaSTv4 Base hardware support UART update firmware. the UART connection is the same as AT Command connection, with the need for two extra action. See below for the steps:
88 88  
89 89   (% style="color:blue" %)**Step1**(%%): Set BOOT Switch to (% style="color:blue" %)**PROG**(%%) mode. PROG mode is for update firmware specially.
... ... @@ -108,13 +108,4 @@
108 108  [[image:image-20221224174341-4.png||height="471" width="374"]]
109 109  
110 110  
111 -
112 -
113 -
114 -
115 -== 3.2 UART Connection for SIB mother board for Program. ==
116 -
117 -
118 -Below shows the SIB board UART connection, reset button and BOOT Switch (Program Jumper) position. They can be used for firmware upgrade reference.
119 -
120 -[[image:image-20221224174605-6.png||height="569" width="880"]]
129 +
image-20230514150410-1.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Edwin
Size
... ... @@ -1,0 +1,1 @@
1 +275.3 KB
Content
Copyright ©2010-2022 Dragino Technology Co., LTD. All rights reserved
Dragino Wiki v2.0