<
From version < 26.21 >
edited by Xiaoling
on 2023/04/20 11:20
To version < 31.1 >
edited by Edwin Chen
on 2023/05/14 16:33
>
Change comment: There is no comment for this version

Summary

Details

Page properties
Author
... ... @@ -1,1 +1,1 @@
1 -XWiki.Xiaoling
1 +XWiki.Edwin
Content
... ... @@ -9,13 +9,23 @@
9 9  = 1. LoRaST v4 base Hardware =
10 10  
11 11  
12 -Below hardware use LoRaST v4 module. They module support UART Access for AT Command and Firmware Upgrade.
12 +Below hardware use LoRaST v4 module. They supports UART Access for AT Command and Firmware Upgrade.
13 13  
14 +{{velocity}}
15 +$xwiki.ssfx.use("js/xwiki/table/table.css")
16 +$xwiki.jsfx.use("js/xwiki/table/tablefilterNsort.js", true)
17 +{{/velocity}}
14 14  
19 +(% border="1" cellspacing="5" class="doOddEven filterable grid sortable" id="tableid" style="width:829px" %)
20 +|(% style="background-color:#d9e2f3; width:290px" %)**Models**|(% style="background-color:#d9e2f3; color:#0070c0; width:172px" %)**Mother Board**|(% style="background-color:#d9e2f3; color:#0070c0; width:116px" %)**UART for AT Commands**|(% style="background-color:#d9e2f3; color:#0070c0; width:248px" %)**UART for Upgrade Firmware**
21 +|(% style="width:290px" %)PS-LB, PS-LB-NA, SDI12-LB|(% style="width:172px" %)SIB|(% style="width:116px" %)Instruction|(% style="width:248px" %)Instruction
22 +|(% style="width:290px" %)(((
23 +SN50v3, S31-LB, S31B-LB,
15 15  
16 -(% border="1" cellspacing="5" style="width:500px" %)
17 -|Models|Mother Board|UART for AT Commands|UART for Upgrade Firmware
18 -| | | |
25 +D20-LB.D20S-LB, D21-LB, D22-LB
26 +)))|(% style="width:172px" %)SN50v3|(% style="width:116px" %) |(% style="width:248px" %)
27 +|(% style="width:290px" %)LHT65N|(% style="width:172px" %)LHT65N|(% style="width:116px" %) |(% style="width:248px" %)
28 +|(% style="width:290px" %) |(% style="width:172px" %) |(% style="width:116px" %) |(% style="width:248px" %)
19 19  
20 20  = 2. UART for AT Commands =
21 21  
... ... @@ -22,13 +22,15 @@
22 22  == 2.1 Generate software set up for AT Commands via UART ==
23 23  
24 24  
25 -(% start="1" style="list-style-type:decimal" %)
26 -1. Use a general serial tool.
27 -1. Connect PC to device's UART interface
28 -1. Set up serial tool with : BaudRate: 9600, databit:8, No parity, No flow control.
29 -1. (((
30 -The password is the last six characters of APPSKEY or PIN of box
35 +~1. Use a general serial tool.
31 31  
37 +2. Connect PC to device's UART interface
38 +
39 +3. Set up serial tool with : BaudRate: 9600, databit:8, No parity, No flow control.
40 +
41 +(((
42 +4. The password is the last six characters of APPSKEY or PIN of box
43 +
32 32  **Example:**
33 33  
34 34  APPSKEY= 41 85 71 A7 5D 7E 54 52 25 58 74 85 96 14 74 85
... ... @@ -52,36 +52,44 @@
52 52  == 2.3 UART Connection for SN50v3 base mother board ==
53 53  
54 54  
67 +
55 55  = 3. UART for Firmware Upgrade =
56 56  
57 -== 3.1 Update firmware ==
70 +== 3.1 Check Your device already have bootloader ==
58 58  
59 -=== 3.1.0 What is Dragino Bootloader? ===
72 +=== 3.1.1 What is Dragino Bootloader? ===
60 60  
74 +
61 61  Dragino Bootloader is a customizer made bootloader which support below features:
62 62  
63 63  * OTA Update via LoRa or BLE
64 64  * OTA Batch update configure via LoRa or BLE
65 65  
66 -{{velocity}}
67 -$xwiki.ssfx.use("js/xwiki/table/table.css")
68 -$xwiki.jsfx.use("js/xwiki/table/tablefilterNsort.js", true)
69 -{{/velocity}}
80 +All Dragino End Devices base on LoRa ST v4 supports Dragino Bootloader.
70 70  
71 71  
72 -(% border="1" cellspacing="5" class="doOddEven filterable grid sortable" id="tableid" style="width:912.222px" %)
73 -|(% style="width:429px" %)Model with LoRa Bootloader|(% style="width:480px" %)Model with BLE Bootloader
74 -|(% style="width:429px" %) |(% style="width:480px" %)
83 +=== 3.1.2 How can i know if my device already have bootloader? ===
75 75  
76 -=== 3.1.1 Update a firmware with Dragino bootloader ===
85 +If a device has a bootloader. it will output bootloader info to UART when boot. As below:
77 77  
87 +[[image:image-20230514150410-1.png||height="398" width="815"]]
78 78  
79 79  
90 +=== 3.1.3 How to upload bootloader to device? ===
80 80  
81 -=== 3.1.2 Update a firmware without bootloader ===
82 82  
83 -If a firmware's name doesn't have the suffix **_with_bootloader**. It means the firmware is without bootloader and user can use this method to uplink.
84 84  
94 +== 3.2 Update Firmware (Assume the device already have a bootloader) ==
95 +
96 +=== 3.2.1 Update a firmware via Dragino bootloader ===
97 +
98 +
99 +
100 +
101 +=== 3.2.2 Update a firmware via TremoProgrammer ===
102 +
103 +Make sure your device already bootloader while use this update. Other device won't be able to boot ( can be solve by upload a bootloader to the device).
104 +
85 85  LoRaSTv4 Base hardware support UART update firmware. the UART connection is the same as AT Command connection, with the need for two extra action. See below for the steps:
86 86  
87 87   (% style="color:blue" %)**Step1**(%%): Set BOOT Switch to (% style="color:blue" %)**PROG**(%%) mode. PROG mode is for update firmware specially.
... ... @@ -106,13 +106,4 @@
106 106  [[image:image-20221224174341-4.png||height="471" width="374"]]
107 107  
108 108  
109 -
110 -
111 -
112 -
113 -== 3.2 UART Connection for SIB mother board for Program. ==
114 -
115 -
116 -Below shows the SIB board UART connection, reset button and BOOT Switch (Program Jumper) position. They can be used for firmware upgrade reference.
117 -
118 -[[image:image-20221224174605-6.png||height="569" width="880"]]
129 +
image-20230514150410-1.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Edwin
Size
... ... @@ -1,0 +1,1 @@
1 +275.3 KB
Content
Copyright ©2010-2022 Dragino Technology Co., LTD. All rights reserved
Dragino Wiki v2.0