From version < 26.20 >
edited by Xiaoling
on 2023/04/20 11:19
To version < 28.1 >
edited by Edwin Chen
on 2023/05/14 15:16
>
Change comment: There is no comment for this version

Summary

Details

Page properties
Author
... ... @@ -1,1 +1,1 @@
1 -XWiki.Xiaoling
1 +XWiki.Edwin
Content
... ... @@ -11,25 +11,30 @@
11 11  
12 12  Below hardware use LoRaST v4 module. They module support UART Access for AT Command and Firmware Upgrade.
13 13  
14 +{{velocity}}
15 +$xwiki.ssfx.use("js/xwiki/table/table.css")
16 +$xwiki.jsfx.use("js/xwiki/table/tablefilterNsort.js", true)
17 +{{/velocity}}
14 14  
19 +(% border="1" cellspacing="5" class="doOddEven filterable grid sortable" id="tableid" style="width:800.222px" %)
20 +|(% style="background-color:#d9e2f3; width:151px" %)**Models**|(% style="background-color:#d9e2f3; color:#0070c0; width:159px" %)**Mother Board**|(% style="background-color:#d9e2f3; color:#0070c0; width:252px" %)**UART for AT Commands**|(% style="background-color:#d9e2f3; color:#0070c0; width:234px" %)**UART for Upgrade Firmware**
21 +|(% style="width:151px" %)PS-LB|(% style="width:159px" %)SIB|(% style="width:252px" %)Instruction|(% style="width:234px" %)Instruction
15 15  
16 -(% border="1" cellspacing="5" style="width:500px" %)
17 -|Models|Mother Board|UART for AT Commands|UART for Upgrade Firmware
18 -| | | |
19 19  
20 -
21 21  = 2. UART for AT Commands =
22 22  
23 23  == 2.1 Generate software set up for AT Commands via UART ==
24 24  
25 25  
26 -(% start="1" style="list-style-type:decimal" %)
27 -1. Use a general serial tool.
28 -1. Connect PC to device's UART interface
29 -1. Set up serial tool with : BaudRate: 9600, databit:8, No parity, No flow control.
30 -1. (((
31 -The password is the last six characters of APPSKEY or PIN of box
29 +~1. Use a general serial tool.
32 32  
31 +2. Connect PC to device's UART interface
32 +
33 +3. Set up serial tool with : BaudRate: 9600, databit:8, No parity, No flow control.
34 +
35 +(((
36 +4. The password is the last six characters of APPSKEY or PIN of box
37 +
33 33  **Example:**
34 34  
35 35  APPSKEY= 41 85 71 A7 5D 7E 54 52 25 58 74 85 96 14 74 85
... ... @@ -53,39 +53,50 @@
53 53  == 2.3 UART Connection for SN50v3 base mother board ==
54 54  
55 55  
61 +
56 56  = 3. UART for Firmware Upgrade =
57 57  
58 -== 3.1 Update firmware ==
64 +== 3.1 Check Your device already have bootloader ==
59 59  
60 -=== 3.1.0 What is Dragino Bootloader? ===
66 +=== 3.1.1 What is Dragino Bootloader? ===
61 61  
68 +
62 62  Dragino Bootloader is a customizer made bootloader which support below features:
63 63  
64 64  * OTA Update via LoRa or BLE
65 65  * OTA Batch update configure via LoRa or BLE
66 66  
74 +(% border="1" cellspacing="5" style="width:912.222px" %)
75 +|(% style="background-color:#d9e2f3; color:#0070c0; width:429px" %)**Model with LoRa Bootloader**|(% style="background-color:#d9e2f3; color:#0070c0; width:480px" %)**Model with BLE Bootloader**
76 +|(% style="width:429px" %)(((
77 +PS-LB, SDI12-LB, PS-LB-NA, SN50v3-LB,
67 67  
68 -{{velocity}}
69 -$xwiki.ssfx.use("js/xwiki/table/table.css")
70 -$xwiki.jsfx.use("js/xwiki/table/tablefilterNsort.js", true)
71 -{{/velocity}}
79 +D2x-LB, S31x-LB, SDI12-LB
80 +)))|(% style="width:480px" %)
72 72  
73 -(% border="1" class="doOddEven filterable grid sortable" id="tableid" style="width:500px %)
74 74  
75 -|Model with LoRa Bootloader|Model with BLE Bootloader
76 -| |
83 +=== 3.1.2 How can i know if my device already have bootloader? ===
77 77  
85 +If a device has a bootloader. it will output bootloader info to UART when boot. As below:
78 78  
87 +[[image:image-20230514150410-1.png||height="398" width="815"]]
79 79  
80 -=== 3.1.1 Update a firmware with Dragino bootloader ===
81 81  
90 +=== 3.1.3 How to upload bootloader to device? ===
82 82  
83 83  
84 84  
85 -=== 3.1.2 Update a firmware without bootloader ===
94 +== 3.2 Update Firmware (Assume the device already have a bootloader) ==
86 86  
87 -If a firmware's name doesn't have the suffix **_with_bootloader**. It means the firmware is without bootloader and user can use this method to uplink.
96 +=== 3.2.1 Update a firmware via Dragino bootloader ===
88 88  
98 +
99 +
100 +
101 +=== 3.2.2 Update a firmware via TremoProgrammer ===
102 +
103 +Make sure your device already bootloader while use this update. Other device won't be able to boot ( can be solve by upload a bootloader to the device).
104 +
89 89  LoRaSTv4 Base hardware support UART update firmware. the UART connection is the same as AT Command connection, with the need for two extra action. See below for the steps:
90 90  
91 91   (% style="color:blue" %)**Step1**(%%): Set BOOT Switch to (% style="color:blue" %)**PROG**(%%) mode. PROG mode is for update firmware specially.
... ... @@ -110,13 +110,4 @@
110 110  [[image:image-20221224174341-4.png||height="471" width="374"]]
111 111  
112 112  
113 -
114 -
115 -
116 -
117 -== 3.2 UART Connection for SIB mother board for Program. ==
118 -
119 -
120 -Below shows the SIB board UART connection, reset button and BOOT Switch (Program Jumper) position. They can be used for firmware upgrade reference.
121 -
122 -[[image:image-20221224174605-6.png||height="569" width="880"]]
129 +
image-20230514150410-1.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Edwin
Size
... ... @@ -1,0 +1,1 @@
1 +275.3 KB
Content
Copyright ©2010-2024 Dragino Technology Co., LTD. All rights reserved
Dragino Wiki v2.0