Changes for page UART Access for LoRa ST v4 base model
Last modified by Mengting Qiu on 2024/11/11 17:09
Change comment:
There is no comment for this version
Summary
-
Page properties (2 modified, 0 added, 0 removed)
Details
- Page properties
-
- Author
-
... ... @@ -1,1 +1,1 @@ 1 -XWiki. Edwin1 +XWiki.Xiaoling - Content
-
... ... @@ -10,10 +10,11 @@ 10 10 11 11 12 12 Below hardware use LoRaST v4 module. They module support UART Access for AT Command and Firmware Upgrade. 13 -{{velocity}}$xwiki.ssfx.use("js/xwiki/table/table.css") 14 -$xwiki.jsfx.use("js/xwiki/table/tablefilterNsort.js", true){{/velocity}} 15 15 16 -(% border="1" cellspacing="10" class="doOddEven filterable grid sortable" id="tableid" style="background-color:#f7faff; width:621.989px" %) 14 + 15 + 16 + 17 +(% border="1" cellspacing="5" class="doOddEven filterable grid sortable" id="tableid" style="background-color:#f7faff; width:621.989px" %) 17 17 (% class="sortHeader" %)|=(% style="width: 77px;" %)Model|=(% style="width: 120px;" %)Mother Board|=(% style="width: 199px;" %)UART for AT Commands|=(% style="width: 221px;" %)UART for Upgrade Firmware 18 18 |(% style="width:77px" %)((( 19 19 PS-LB ... ... @@ -58,9 +58,35 @@ 58 58 59 59 == 3.1 Update firmware == 60 60 61 -=== 3.1. 1Updatea firmware withoutbootloader ===62 +=== 3.1.0 What is Dragino Bootloader? === 62 62 64 +Dragino Bootloader is a customizer made bootloader which support below features: 63 63 66 +* OTA Update via LoRa or BLE 67 +* OTA Batch update configure via LoRa or BLE 68 + 69 +{{velocity}} 70 +$xwiki.ssfx.use("js/xwiki/table/table.css") 71 +$xwiki.jsfx.use("js/xwiki/table/tablefilterNsort.js", true) 72 +{{/velocity}} 73 + 74 +(% border="1" cellspacing="10" class="doOddEven filterable grid sortable" id="tableid" style="background-color:#f7faff; width:621.989px" %) 75 +(% class="sortHeader" %)|=(% style="width: 307px;" %)Model with LoRa Bootloader|=(% style="width: 313px;" %)Model with BLE Bootloader 76 +|(% style="width:307px" %)((( 77 +PS-LB, SDI12-LB, PS-LB-NA, SN50v3-LB, 78 + 79 +D2x-LB, S31x-LB, SDI12-LB 80 +)))|(% style="width:313px" %) 81 + 82 +=== 3.1.1 Update a firmware with Dragino bootloader === 83 + 84 + 85 + 86 + 87 +=== 3.1.2 Update a firmware without bootloader === 88 + 89 +If a firmware's name doesn't have the suffix **_with_bootloader**. It means the firmware is without bootloader and user can use this method to uplink. 90 + 64 64 LoRaSTv4 Base hardware support UART update firmware. the UART connection is the same as AT Command connection, with the need for two extra action. See below for the steps: 65 65 66 66 (% style="color:blue" %)**Step1**(%%): Set BOOT Switch to (% style="color:blue" %)**PROG**(%%) mode. PROG mode is for update firmware specially. ... ... @@ -78,7 +78,7 @@ 78 78 79 79 2. Run** (% style="color:blue" %)TremoProgrammer.(%%)** 80 80 81 -3. Choose software and set the address to (% style="color:blue" %)**0x0800D000(%%) **. (% style="color:red" %)VERY IMPORTANT: USE THIS ADDRESS FOR FIRMWARE WITHOUT BOOTLOADER(%%)108 +3. Choose software and set the address to (% style="color:blue" %)**0x0800D000**(%%). (% style="color:red" %)VERY IMPORTANT: USE THIS ADDRESS FOR FIRMWARE WITHOUT BOOTLOADER 82 82 83 83 4. Rember to set BOOT Switch to (% style="color:blue" %)**FLASH**(%%) after update 84 84 ... ... @@ -85,6 +85,10 @@ 85 85 [[image:image-20221224174341-4.png||height="471" width="374"]] 86 86 87 87 115 + 116 + 117 + 118 + 88 88 == 3.2 UART Connection for SIB mother board for Program. == 89 89 90 90