From version < 1.5 >
edited by Xiaoling
on 2022/05/12 17:05
To version < 1.11 >
edited by Xiaoling
on 2022/05/27 14:40
>
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -1,6 +1,8 @@
1 -Contents:
1 +**Contents:**
2 2  
3 +{{toc/}}
3 3  
5 +
4 4  = 1. Introduction =
5 5  
6 6  In the TCP IP Client mode, LoRa Gateway can accept LoRa or LoRaWAN packets and send it to the TCP/IP server.
... ... @@ -27,10 +27,9 @@
27 27  
28 28  == 3.1 Support Hardware ==
29 29  
30 -* LG01N, OLG01N
31 -* LG02, OLG02
32 +* [[LG01-N>>url:http://www.dragino.com/products/lora-lorawan-gateway/item/143-lg01n.html]], [[OLG01-N>>url:http://www.dragino.com/products/lora-lorawan-gateway/item/144-olg01n.html]]
33 +* [[LG02>>url:http://www.dragino.com/products/lora-lorawan-gateway/item/135-lg02.html]], [[OLG02>>url:http://www.dragino.com/products/lora-lorawan-gateway/item/136-olg02.html]]
32 32  
33 -
34 34  == 3.2 Typology ==
35 35  
36 36  The working topology is as below. In this mode, The Uplink LoRa packets should use a customized format.
... ... @@ -65,7 +65,7 @@
65 65  Configure TCP Server Info
66 66  
67 67  
68 -=== 3.4 About uplink data format from End Node ===
69 +=== 3.3.4 About uplink data format from End Node ===
69 69  
70 70  The LoRa end node should upload the data with below format:
71 71  
... ... @@ -89,8 +89,7 @@
89 89  
90 90  Configure TCP Server Info
91 91  
92 -{{{LoRa End Device reference source code: .
93 -}}}
93 +LoRa End Device reference source code: [[check this link>>url:https://github.com/dragino/Arduino-Profile-Examples/blob/master/libraries/Dragino/examples/IoTServer/ThingSpeak/MQTT_Client/MQTT_DHT11_Client_updata_to_ThingSpeak_/MQTT_DHT11_Client_updata_to_ThingSpeak_.ino]].
94 94  
95 95  
96 96  == 3.4 Instruction After Firmware lgw~-~-build~-~-v5.4.1612428704~-~-20210204-1653 ==
... ... @@ -115,26 +115,30 @@
115 115  
116 116  The LoRa end node should upload the data with below format:
117 117  
118 -{{{Uplink Format: <Channel_ID>data
118 +(% class="box" %)
119 +(((
120 +Uplink Format: **<Channel_ID>data**
119 119  And there is a LoRa End node sending below packets:
120 120  *<12345>Hello From Sensor1
121 -}}}
123 +)))
122 122  
123 123  
124 -{{{LG01/LG02 will uplink 12345:Hello From Sensor1 and usr can use logread -f to check the log.
125 -Thu Feb 4 08:21:49 2021 user.notice iot_keep_alive: use WAN or WiFi for internet access now
126 -Thu Feb 4 08:21:53 2021 daemon.info tcp_process.sh[18564]: /var/iot/channels/ CREATE 12345
127 -Thu Feb 4 08:21:53 2021 user.notice root: [IoT.TCP]: Check for sensor update
128 -Thu Feb 4 08:21:53 2021 user.notice root: [IoT.TCP]: Found Data at Local Channels: 12345
129 -Thu Feb 4 08:21:53 2021 user.notice root: [IoT.TCP]:
130 -Thu Feb 4 08:21:53 2021 user.notice root: [IoT.TCP]:-----
131 -Thu Feb 4 08:21:53 2021 user.notice root: [IoT.TCP]:server: 10.130.2.149
132 -Thu Feb 4 08:21:53 2021 user.notice root: [IoT.TCP]:port: 60000
133 -Thu Feb 4 08:21:53 2021 user.notice root: [IoT.TCP]:decoder: LG01/LG02 Raw Data
134 -Thu Feb 4 08:21:53 2021 user.notice root: [IoT.TCP]:tcp_data: 12345:Hello From Sensor1;
135 -Thu Feb 4 08:21:53 2021 user.notice root: [IoT.TCP]:------
126 +(% class="box" %)
127 +(((
128 +LG01/LG02 will uplink 12345:Hello From Sensor1 and usr can use logread -f to check the log.
129 +Thu Feb  4 08:21:49 2021 user.notice iot_keep_alive: use WAN or WiFi for internet access now
130 +Thu Feb  4 08:21:53 2021 daemon.info tcp_process.sh[18564]: /var/iot/channels/ CREATE 12345
131 +Thu Feb  4 08:21:53 2021 user.notice root: [IoT.TCP]: Check for sensor update
132 +Thu Feb  4 08:21:53 2021 user.notice root: [IoT.TCP]: Found Data at Local Channels: 12345
133 +Thu Feb  4 08:21:53 2021 user.notice root: [IoT.TCP]:
134 +Thu Feb  4 08:21:53 2021 user.notice root: [IoT.TCP]:~-~-~-~--
135 +Thu Feb  4 08:21:53 2021 user.notice root: [IoT.TCP]:server: 10.130.2.149
136 +Thu Feb  4 08:21:53 2021 user.notice root: [IoT.TCP]:port: 60000
137 +Thu Feb  4 08:21:53 2021 user.notice root: [IoT.TCP]:decoder: LG01/LG02 Raw Data
138 +Thu Feb  4 08:21:53 2021 user.notice root: [IoT.TCP]:tcp_data: 12345:Hello From Sensor1;
139 +Thu Feb  4 08:21:53 2021 user.notice root: [IoT.TCP]:~-~-~-~-~-~-
140 +)))
136 136  
137 -}}}
138 138  
139 139  and TCP server get:
140 140  
... ... @@ -142,9 +142,9 @@
142 142  
143 143  TCP Server
144 144  
145 -{{{LoRa End Device reference source code: .
146 -}}}
149 +LoRa End Device reference source code: [[check this link>>url:https://github.com/dragino/Arduino-Profile-Examples/blob/master/libraries/Dragino/examples/IoTServer/ThingSpeak/MQTT_Client/MQTT_DHT11_Client_updata_to_ThingSpeak_/MQTT_DHT11_Client_updata_to_ThingSpeak_.ino]].
147 147  
151 +
148 148  = 4. Reference =
149 149  
150 150  Set up a TCP/IP server use node.js: [[Reference Link>>url:http://www.dragino.com/downloads/index.php?dir=LoRa_Gateway/LG02-OLG02/Firmware/customized_script/&file=node_tcp_server.txt]]
Copyright ©2010-2022 Dragino Technology Co., LTD. All rights reserved