<
From version < 24.1 >
edited by Herong Lu
on 2023/10/10 14:54
To version < 16.2 >
edited by Xiaoling
on 2023/10/07 14:43
>
Change comment: There is no comment for this version

Summary

Details

Page properties
Author
... ... @@ -1,1 +1,1 @@
1 -XWiki.Lu
1 +XWiki.Xiaoling
Content
... ... @@ -1,4 +1,4 @@
1 -= **Table of Contents:** =
1 +**Table of Contents:**
2 2  
3 3  {{toc/}}
4 4  
... ... @@ -23,6 +23,8 @@
23 23  
24 24  * Import / Export commands
25 25  
26 +
27 +
26 26  = 2. Hardware Connection =
27 27  
28 28  
... ... @@ -30,7 +30,7 @@
30 30  
31 31  **[[Download RS485 Configure Tool>>https://www.dropbox.com/sh/us9qecn39fwt8n1/AABREdqUCzEmJMRrfuWuXasoa?dl=0]]**.
32 32  
33 -[[image:image-20230928230446-1.png||_mstalt="431288" height="275" width="471"]]
35 +[[image:image-20230928230446-1.png||height="275" width="471"]]
34 34  
35 35  = 3. Use the tool =
36 36  
... ... @@ -39,34 +39,33 @@
39 39  
40 40  Below is the block diagram of the RS485 Tool:
41 41  
42 -[[image:image-20230928235259-4.png||_mstalt="434590" height="681" width="915"]]
44 +[[image:image-20230928235259-4.png||height="681" width="915"]]
43 43  
44 -Below is the block diagram of the RS485 Tool V1.2:
45 45  
47 +== 3.1 General Configure: ==
46 46  
47 47  
48 -== 3.1 General Configure: ==
50 +* (% style="color:blue" %)**Port**(%%): COM port in PC to connect to RS485 End Node.
49 49  
52 +* (% style="color:blue" %)**Node Baud Rate**(%%): The Baud Rate for RS485 End Node.
50 50  
51 -* (% style="color:blue" %)**Port **(%%): COM port in PC to connect to RS485 End Node.
54 +* (% style="color:blue" %)**5VT**(%%): 5v Power_On_Duration for external RS485 Sensors. Unit: ms.
52 52  
53 -* (% style="color:blue" %)**Node Baud Rate **(%%): The Baud Rate for RS485 End Node.
56 +* (% style="color:blue" %)**Connect End Node**(%%): Connect to RS485 End Node.
54 54  
55 -* (% style="color:blue" %)**5VT **(%%): 5v Power_On_Duration for external RS485 Sensors. Unit: ms.
58 +* (% style="color:blue" %)**Disconnect End Node**(%%): Disconnect RS485 End Node.
56 56  
57 -* (% style="color:blue" %)**Connect End Node **(%%): Connect to RS485 End Node.
60 +* (% style="color:blue" %)**Sensor Baud Rate**(%%): Baud Rate of RS485 Sensors.
58 58  
59 -* (% style="color:blue" %)**Disconnect End Node **(%%): Disconnect RS485 End Node.
62 +* (% style="color:blue" %)**Sensor Data Bit**(%%): Data Bit of RS485 Sensors
60 60  
61 -* (% style="color:blue" %)**Sensor Baud Rate **(%%): Baud Rate of RS485 Sensors.
64 +* (% style="color:blue" %)**Sensor Check Bit**(%%): Check Bit of RS485 Sensors.
62 62  
63 -* (% style="color:blue" %)**Sensor Data Bit **(%%): Data Bit of RS485 Sensors
66 +* (% style="color:blue" %)**Sensor Stop Bit**(%%): Stop Bit of RS485 Sensors
64 64  
65 -* (% style="color:blue" %)**Sensor Check Bit **(%%): Check Bit of RS485 Sensors.
68 +* (% style="color:blue" %)**Configure Devices**(%%): Send General Configure Command to End Node.
66 66  
67 -* (% style="color:blue" %)**Sensor Stop Bit **(%%): Stop Bit of RS485 Sensors
68 68  
69 -* (% style="color:blue" %)**Configure Devices **(%%): Send General Configure Command to End Node.
70 70  
71 71  == 3.2 Console Window: ==
72 72  
... ... @@ -75,7 +75,7 @@
75 75  
76 76  User can also Send AT Commands to RS485 End Node in this window.
77 77  
78 -[[image:image-20230928233408-3.png||_mstalt="432289"]]
79 +[[image:image-20230928233408-3.png]]
79 79  
80 80  
81 81  == 3.3 RS485 Commands to Sensor ==
... ... @@ -117,20 +117,20 @@
117 117  
118 118  Their returnes will be shown in "RS485 Return Data" Area, such as below:
119 119  
120 -[[image:image-20230930193108-1.png||_mstalt="430235"]]
121 +[[image:image-20230930193108-1.png]]
121 121  
122 122  Use can choose to get "Discrete Data Bytes" or "Bytes Blocks":
123 123  
124 -[[image:image-20230930193257-2.png||_mstalt="432198"]] Select the 1st ~~ 3rd bytes from the return.
125 +[[image:image-20230930193257-2.png]] Select the 1st ~~ 3rd bytes from the return.
125 125  
126 -[[image:image-20230930193357-3.png||_mstalt="432874"]] Select the 3rd, 6th, 9th bytes from the return.
127 +[[image:image-20230930193357-3.png]] Select the 3rd, 6th, 9th bytes from the return.
127 127  
128 -[[image:image-20230930193456-4.png||_mstalt="433212"]] After select the byte fetch method. User can see preview the result. This photo shows to fetch the Block 1~~3 from the first return.
129 +[[image:image-20230930193456-4.png]] After select the byte fetch method. User can see preview the result. This photo shows to fetch the Block 1~~3 from the first return.
129 129  
130 130  
131 131  Below is the full screen shot:
132 132  
133 -[[image:image-20230930193658-5.png||_mstalt="434876" height="735" width="1146"]]
134 +[[image:image-20230930193658-5.png||height="735" width="1146"]]
134 134  
135 135  
136 136  (% style="color:blue" %)**AT+CMDDL**(%%): This specify the delay for RS485 End Node to wait for the RS485 sensors return. If RS485 sensors doesn't reply in this time. End Node will consider there is no reply.
... ... @@ -143,36 +143,25 @@
143 143  
144 144  This window show the commands to be flash into the RS485 end node.
145 145  
146 -* (% style="color:blue" %)**Import Commands **(%%): Import commands from txt.
147 +* (% style="color:blue" %)**Import Commands**(%%): Import commands from txt.
147 147  
148 -* (% style="color:blue" %)**Save Commands **(%%): Save commands to a txt.
149 +* (% style="color:blue" %)**Save Commands**(%%): Save commands to a txt.
149 149  
150 -* (% style="color:blue" %)**Write **(%%): Write Commands to End Node
151 +* (% style="color:blue" %)**Write**(%%): Write Commands to End Node
151 151  
152 -* (% style="color:blue" %)**Erase All **(%%): Clear All Configured Commands in the RS485. It won't erase the commands shows in the preview window.
153 +* (% style="color:blue" %)**Erase All**(%%): Clear All Configured Commands in the RS485. It won't erase the commands shows in the preview window.
153 153  
154 -== Change Log: ==
155 155  
156 -=== v1.1: ===
157 157  
158 -1.No spaces are required between each byte of the inquiry frame
159 159  
160 -2.Improve the prompt box
158 += TODO: =
161 161  
162 -3.AT instruction coverage function
160 +~1. Add Payload Structure Window
163 163  
164 -4.Button function prompt
162 +2. Modify Chars to looks nicer
165 165  
166 -=== V1.2: ===
164 +3. Each COmmand can have seperate return process command.
167 167  
168 -1.Fixed overwrite failure when AT instruction has multiple parameters
166 +4.
169 169  
170 -2.Add Payload Structure Window
171 -
172 -= TODO: =
173 -
174 -~1. Add Payload Structure Window(Done at v1.2)
175 -
176 -2. Modify Chars to looks nicer  ( Done at v1.1)
177 -
178 178  
image-20231010145353-1.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Lu
Size
... ... @@ -1,1 +1,0 @@
1 -145.4 KB
Content
image-20231010145454-2.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Lu
Size
... ... @@ -1,1 +1,0 @@
1 -118.4 KB
Content
Copyright ©2010-2024 Dragino Technology Co., LTD. All rights reserved
Dragino Wiki v2.0