<
From version < 20.1 >
edited by Herong Lu
on 2023/10/10 14:08
To version < 22.1 >
edited by Herong Lu
on 2023/10/10 14:13
>
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -30,7 +30,7 @@
30 30  
31 31  **[[Download RS485 Configure Tool>>https://www.dropbox.com/sh/us9qecn39fwt8n1/AABREdqUCzEmJMRrfuWuXasoa?dl=0]]**.
32 32  
33 -[[image:image-20230928230446-1.png||height="275" width="471"]]
33 +[[image:image-20230928230446-1.png||_mstalt="431288" height="275" width="471"]]
34 34  
35 35  = 3. Use the tool =
36 36  
... ... @@ -39,9 +39,12 @@
39 39  
40 40  Below is the block diagram of the RS485 Tool:
41 41  
42 -[[image:image-20230928235259-4.png||height="681" width="915"]]
42 +[[image:image-20230928235259-4.png||_mstalt="434590" height="681" width="915"]]
43 43  
44 +Below is the block diagram of the RS485 Tool V1.2:
44 44  
46 +
47 +
45 45  == 3.1 General Configure: ==
46 46  
47 47  
... ... @@ -72,7 +72,7 @@
72 72  
73 73  User can also Send AT Commands to RS485 End Node in this window.
74 74  
75 -[[image:image-20230928233408-3.png]]
78 +[[image:image-20230928233408-3.png||_mstalt="432289"]]
76 76  
77 77  
78 78  == 3.3 RS485 Commands to Sensor ==
... ... @@ -114,20 +114,20 @@
114 114  
115 115  Their returnes will be shown in "RS485 Return Data" Area, such as below:
116 116  
117 -[[image:image-20230930193108-1.png]]
120 +[[image:image-20230930193108-1.png||_mstalt="430235"]]
118 118  
119 119  Use can choose to get "Discrete Data Bytes" or "Bytes Blocks":
120 120  
121 -[[image:image-20230930193257-2.png]] Select the 1st ~~ 3rd bytes from the return.
124 +[[image:image-20230930193257-2.png||_mstalt="432198"]] Select the 1st ~~ 3rd bytes from the return.
122 122  
123 -[[image:image-20230930193357-3.png]] Select the 3rd, 6th, 9th bytes from the return.
126 +[[image:image-20230930193357-3.png||_mstalt="432874"]] Select the 3rd, 6th, 9th bytes from the return.
124 124  
125 -[[image:image-20230930193456-4.png]] After select the byte fetch method. User can see preview the result. This photo shows to fetch the Block 1~~3 from the first return.
128 +[[image:image-20230930193456-4.png||_mstalt="433212"]] After select the byte fetch method. User can see preview the result. This photo shows to fetch the Block 1~~3 from the first return.
126 126  
127 127  
128 128  Below is the full screen shot:
129 129  
130 -[[image:image-20230930193658-5.png||height="735" width="1146"]]
133 +[[image:image-20230930193658-5.png||_mstalt="434876" height="735" width="1146"]]
131 131  
132 132  
133 133  (% style="color:blue" %)**AT+CMDDL**(%%): This specify the delay for RS485 End Node to wait for the RS485 sensors return. If RS485 sensors doesn't reply in this time. End Node will consider there is no reply.
... ... @@ -150,7 +150,7 @@
150 150  
151 151  == Change Log: ==
152 152  
153 -== v1.1: ==
156 +=== v1.1: ===
154 154  
155 155  1.No spaces are required between each byte of the inquiry frame
156 156  
... ... @@ -160,7 +160,7 @@
160 160  
161 161  4.Button function prompt
162 162  
163 -== V1.2: ==
166 +=== V1.2: ===
164 164  
165 165  1.Fixed overwrite failure when AT instruction has multiple parameters
166 166  
... ... @@ -168,7 +168,6 @@
168 168  
169 169  = TODO: =
170 170  
171 -
172 172  ~1. Add Payload Structure Window(Done at v1.2)
173 173  
174 174  2. Modify Chars to looks nicer  ( Done at v1.1)
Copyright ©2010-2024 Dragino Technology Co., LTD. All rights reserved
Dragino Wiki v2.0