<
From version < 20.1 >
edited by Herong Lu
on 2023/10/10 14:08
To version < 16.2 >
edited by Xiaoling
on 2023/10/07 14:43
>
Change comment: There is no comment for this version

Summary

Details

Page properties
Author
... ... @@ -1,1 +1,1 @@
1 -XWiki.Lu
1 +XWiki.Xiaoling
Content
... ... @@ -1,4 +1,4 @@
1 -= **Table of Contents:** =
1 +**Table of Contents:**
2 2  
3 3  {{toc/}}
4 4  
... ... @@ -23,6 +23,8 @@
23 23  
24 24  * Import / Export commands
25 25  
26 +
27 +
26 26  = 2. Hardware Connection =
27 27  
28 28  
... ... @@ -45,26 +45,28 @@
45 45  == 3.1 General Configure: ==
46 46  
47 47  
48 -* (% style="color:blue" %)**Port **(%%): COM port in PC to connect to RS485 End Node.
50 +* (% style="color:blue" %)**Port**(%%): COM port in PC to connect to RS485 End Node.
49 49  
50 -* (% style="color:blue" %)**Node Baud Rate **(%%): The Baud Rate for RS485 End Node.
52 +* (% style="color:blue" %)**Node Baud Rate**(%%): The Baud Rate for RS485 End Node.
51 51  
52 -* (% style="color:blue" %)**5VT **(%%): 5v Power_On_Duration for external RS485 Sensors. Unit: ms.
54 +* (% style="color:blue" %)**5VT**(%%): 5v Power_On_Duration for external RS485 Sensors. Unit: ms.
53 53  
54 -* (% style="color:blue" %)**Connect End Node **(%%): Connect to RS485 End Node.
56 +* (% style="color:blue" %)**Connect End Node**(%%): Connect to RS485 End Node.
55 55  
56 -* (% style="color:blue" %)**Disconnect End Node **(%%): Disconnect RS485 End Node.
58 +* (% style="color:blue" %)**Disconnect End Node**(%%): Disconnect RS485 End Node.
57 57  
58 -* (% style="color:blue" %)**Sensor Baud Rate **(%%): Baud Rate of RS485 Sensors.
60 +* (% style="color:blue" %)**Sensor Baud Rate**(%%): Baud Rate of RS485 Sensors.
59 59  
60 -* (% style="color:blue" %)**Sensor Data Bit **(%%): Data Bit of RS485 Sensors
62 +* (% style="color:blue" %)**Sensor Data Bit**(%%): Data Bit of RS485 Sensors
61 61  
62 -* (% style="color:blue" %)**Sensor Check Bit **(%%): Check Bit of RS485 Sensors.
64 +* (% style="color:blue" %)**Sensor Check Bit**(%%): Check Bit of RS485 Sensors.
63 63  
64 -* (% style="color:blue" %)**Sensor Stop Bit **(%%): Stop Bit of RS485 Sensors
66 +* (% style="color:blue" %)**Sensor Stop Bit**(%%): Stop Bit of RS485 Sensors
65 65  
66 -* (% style="color:blue" %)**Configure Devices **(%%): Send General Configure Command to End Node.
68 +* (% style="color:blue" %)**Configure Devices**(%%): Send General Configure Command to End Node.
67 67  
70 +
71 +
68 68  == 3.2 Console Window: ==
69 69  
70 70  
... ... @@ -140,37 +140,25 @@
140 140  
141 141  This window show the commands to be flash into the RS485 end node.
142 142  
143 -* (% style="color:blue" %)**Import Commands **(%%): Import commands from txt.
147 +* (% style="color:blue" %)**Import Commands**(%%): Import commands from txt.
144 144  
145 -* (% style="color:blue" %)**Save Commands **(%%): Save commands to a txt.
149 +* (% style="color:blue" %)**Save Commands**(%%): Save commands to a txt.
146 146  
147 -* (% style="color:blue" %)**Write **(%%): Write Commands to End Node
151 +* (% style="color:blue" %)**Write**(%%): Write Commands to End Node
148 148  
149 -* (% style="color:blue" %)**Erase All **(%%): Clear All Configured Commands in the RS485. It won't erase the commands shows in the preview window.
153 +* (% style="color:blue" %)**Erase All**(%%): Clear All Configured Commands in the RS485. It won't erase the commands shows in the preview window.
150 150  
151 -== Change Log: ==
152 152  
153 -== v1.1: ==
154 154  
155 -1.No spaces are required between each byte of the inquiry frame
156 156  
157 -2.Improve the prompt box
158 -
159 -3.AT instruction coverage function
160 -
161 -4.Button function prompt
162 -
163 -== V1.2: ==
164 -
165 -1.Fixed overwrite failure when AT instruction has multiple parameters
166 -
167 -2.Add Payload Structure Window
168 -
169 169  = TODO: =
170 170  
160 +~1. Add Payload Structure Window
171 171  
172 -~1. Add Payload Structure Window(Done at v1.2)
162 +2. Modify Chars to looks nicer
173 173  
174 -2. Modify Chars to looks nicer  ( Done at v1.1)
164 +3. Each COmmand can have seperate return process command.
175 175  
166 +4.
167 +
176 176  
Copyright ©2010-2024 Dragino Technology Co., LTD. All rights reserved
Dragino Wiki v2.0