<
From version < 16.2 >
edited by Xiaoling
on 2023/10/07 14:43
To version < 24.1 >
edited by Herong Lu
on 2023/10/10 14:54
>
Change comment: Uploaded new attachment "image-20231010145454-2.png", version {1}

Summary

Details

Page properties
Author
... ... @@ -1,1 +1,1 @@
1 -XWiki.Xiaoling
1 +XWiki.Lu
Content
... ... @@ -1,4 +1,4 @@
1 -**Table of Contents:**
1 += **Table of Contents:** =
2 2  
3 3  {{toc/}}
4 4  
... ... @@ -23,8 +23,6 @@
23 23  
24 24  * Import / Export commands
25 25  
26 -
27 -
28 28  = 2. Hardware Connection =
29 29  
30 30  
... ... @@ -32,7 +32,7 @@
32 32  
33 33  **[[Download RS485 Configure Tool>>https://www.dropbox.com/sh/us9qecn39fwt8n1/AABREdqUCzEmJMRrfuWuXasoa?dl=0]]**.
34 34  
35 -[[image:image-20230928230446-1.png||height="275" width="471"]]
33 +[[image:image-20230928230446-1.png||_mstalt="431288" height="275" width="471"]]
36 36  
37 37  = 3. Use the tool =
38 38  
... ... @@ -41,33 +41,34 @@
41 41  
42 42  Below is the block diagram of the RS485 Tool:
43 43  
44 -[[image:image-20230928235259-4.png||height="681" width="915"]]
42 +[[image:image-20230928235259-4.png||_mstalt="434590" height="681" width="915"]]
45 45  
44 +Below is the block diagram of the RS485 Tool V1.2:
46 46  
47 -== 3.1 General Configure: ==
48 48  
49 49  
50 -* (% style="color:blue" %)**Port**(%%): COM port in PC to connect to RS485 End Node.
48 +== 3.1 General Configure: ==
51 51  
52 -* (% style="color:blue" %)**Node Baud Rate**(%%): The Baud Rate for RS485 End Node.
53 53  
54 -* (% style="color:blue" %)**5VT**(%%): 5v Power_On_Duration for external RS485 Sensors. Unit: ms.
51 +* (% style="color:blue" %)**Port **(%%): COM port in PC to connect to RS485 End Node.
55 55  
56 -* (% style="color:blue" %)**Connect End Node**(%%): Connect to RS485 End Node.
53 +* (% style="color:blue" %)**Node Baud Rate **(%%): The Baud Rate for RS485 End Node.
57 57  
58 -* (% style="color:blue" %)**Disconnect End Node**(%%): Disconnect RS485 End Node.
55 +* (% style="color:blue" %)**5VT **(%%): 5v Power_On_Duration for external RS485 Sensors. Unit: ms.
59 59  
60 -* (% style="color:blue" %)**Sensor Baud Rate**(%%): Baud Rate of RS485 Sensors.
57 +* (% style="color:blue" %)**Connect End Node **(%%): Connect to RS485 End Node.
61 61  
62 -* (% style="color:blue" %)**Sensor Data Bit**(%%): Data Bit of RS485 Sensors
59 +* (% style="color:blue" %)**Disconnect End Node **(%%): Disconnect RS485 End Node.
63 63  
64 -* (% style="color:blue" %)**Sensor Check Bit**(%%): Check Bit of RS485 Sensors.
61 +* (% style="color:blue" %)**Sensor Baud Rate **(%%): Baud Rate of RS485 Sensors.
65 65  
66 -* (% style="color:blue" %)**Sensor Stop Bit**(%%): Stop Bit of RS485 Sensors
63 +* (% style="color:blue" %)**Sensor Data Bit **(%%): Data Bit of RS485 Sensors
67 67  
68 -* (% style="color:blue" %)**Configure Devices**(%%): Send General Configure Command to End Node.
65 +* (% style="color:blue" %)**Sensor Check Bit **(%%): Check Bit of RS485 Sensors.
69 69  
67 +* (% style="color:blue" %)**Sensor Stop Bit **(%%): Stop Bit of RS485 Sensors
70 70  
69 +* (% style="color:blue" %)**Configure Devices **(%%): Send General Configure Command to End Node.
71 71  
72 72  == 3.2 Console Window: ==
73 73  
... ... @@ -76,7 +76,7 @@
76 76  
77 77  User can also Send AT Commands to RS485 End Node in this window.
78 78  
79 -[[image:image-20230928233408-3.png]]
78 +[[image:image-20230928233408-3.png||_mstalt="432289"]]
80 80  
81 81  
82 82  == 3.3 RS485 Commands to Sensor ==
... ... @@ -118,20 +118,20 @@
118 118  
119 119  Their returnes will be shown in "RS485 Return Data" Area, such as below:
120 120  
121 -[[image:image-20230930193108-1.png]]
120 +[[image:image-20230930193108-1.png||_mstalt="430235"]]
122 122  
123 123  Use can choose to get "Discrete Data Bytes" or "Bytes Blocks":
124 124  
125 -[[image:image-20230930193257-2.png]] Select the 1st ~~ 3rd bytes from the return.
124 +[[image:image-20230930193257-2.png||_mstalt="432198"]] Select the 1st ~~ 3rd bytes from the return.
126 126  
127 -[[image:image-20230930193357-3.png]] Select the 3rd, 6th, 9th bytes from the return.
126 +[[image:image-20230930193357-3.png||_mstalt="432874"]] Select the 3rd, 6th, 9th bytes from the return.
128 128  
129 -[[image:image-20230930193456-4.png]] After select the byte fetch method. User can see preview the result. This photo shows to fetch the Block 1~~3 from the first return.
128 +[[image:image-20230930193456-4.png||_mstalt="433212"]] After select the byte fetch method. User can see preview the result. This photo shows to fetch the Block 1~~3 from the first return.
130 130  
131 131  
132 132  Below is the full screen shot:
133 133  
134 -[[image:image-20230930193658-5.png||height="735" width="1146"]]
133 +[[image:image-20230930193658-5.png||_mstalt="434876" height="735" width="1146"]]
135 135  
136 136  
137 137  (% style="color:blue" %)**AT+CMDDL**(%%): This specify the delay for RS485 End Node to wait for the RS485 sensors return. If RS485 sensors doesn't reply in this time. End Node will consider there is no reply.
... ... @@ -144,25 +144,36 @@
144 144  
145 145  This window show the commands to be flash into the RS485 end node.
146 146  
147 -* (% style="color:blue" %)**Import Commands**(%%): Import commands from txt.
146 +* (% style="color:blue" %)**Import Commands **(%%): Import commands from txt.
148 148  
149 -* (% style="color:blue" %)**Save Commands**(%%): Save commands to a txt.
148 +* (% style="color:blue" %)**Save Commands **(%%): Save commands to a txt.
150 150  
151 -* (% style="color:blue" %)**Write**(%%): Write Commands to End Node
150 +* (% style="color:blue" %)**Write **(%%): Write Commands to End Node
152 152  
153 -* (% style="color:blue" %)**Erase All**(%%): Clear All Configured Commands in the RS485. It won't erase the commands shows in the preview window.
152 +* (% style="color:blue" %)**Erase All **(%%): Clear All Configured Commands in the RS485. It won't erase the commands shows in the preview window.
154 154  
154 +== Change Log: ==
155 155  
156 +=== v1.1: ===
156 156  
158 +1.No spaces are required between each byte of the inquiry frame
157 157  
158 -= TODO: =
160 +2.Improve the prompt box
159 159  
160 -~1. Add Payload Structure Window
162 +3.AT instruction coverage function
161 161  
162 -2. Modify Chars to looks nicer
164 +4.Button function prompt
163 163  
164 -3. Each COmmand can have seperate return process command.
166 +=== V1.2: ===
165 165  
166 -4.
168 +1.Fixed overwrite failure when AT instruction has multiple parameters
167 167  
170 +2.Add Payload Structure Window
171 +
172 += TODO: =
173 +
174 +~1. Add Payload Structure Window(Done at v1.2)
175 +
176 +2. Modify Chars to looks nicer  ( Done at v1.1)
177 +
168 168  
image-20231010145353-1.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Lu
Size
... ... @@ -1,0 +1,1 @@
1 +145.4 KB
Content
image-20231010145454-2.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Lu
Size
... ... @@ -1,0 +1,1 @@
1 +118.4 KB
Content
Copyright ©2010-2024 Dragino Technology Co., LTD. All rights reserved
Dragino Wiki v2.0