Changes for page Packet Reject Issue

Last modified by Xiaoling on 2022/07/22 11:00

From version 1.2
edited by Xiaoling
on 2022/05/14 10:11
Change comment: There is no comment for this version
To version 2.1
edited by Xiaoling
on 2022/07/22 11:00
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -1,32 +1,35 @@
1 1  (% style="color:red" %)**Note: This issue is fixed since firmware version: LG02_LG08~-~-build-v5.3.1584002217-20200312-1639**
2 2  
3 +
3 3  = Paject Reject due to Power RF =
4 4  
5 -Issue as below
6 6  
7 -(((
8 -Sat Feb 29 08:10:26 2020 daemon.info lora_pkt_fwd[30684]: RXTX~~ {"txpk":
9 -)))
7 +Issue as below:
10 10  
9 +(% class="box" %)
11 11  (((
11 +**Sat Feb 29 08:10:26 2020 daemon.info lora_pkt_fwd[30684]: RXTX~~ {"txpk":
12 12  {"imme":false,"tmst":510528462,"freq":923.9,"rfch":0,"powe":17,"modu":"LORA","datr":"SF7BW500","codr":"4/5","ipol":true,"size":17,"ncrc":true,"data":"IKnZOasAq17SeIpOQc0ZzBQ="}}
13 +Sat Feb 29 08:10:26 2020 daemon.info lora_pkt_fwd[30684]: ERROR~~ Packet REJECTED, unsupported RF power for TX - 17**
13 13  )))
14 14  
15 15  (((
16 -Sat Feb 29 08:10:26 2020 daemon.info lora_pkt_fwd[30684]: ERROR~~ Packet REJECTED, unsupported RF power for TX - 17
17 -)))
18 -
19 19  This is due to the lorawan server use a power that the gateway not yet configured.
20 20  
19 +
20 +)))
21 +
22 +(((
21 21  User can find the related region file in /etc/lora/cfg and change the parameter to support the power. for example to support 17, user can change as below and reboot
24 +)))
22 22  
23 23  (% class="box" %)
24 24  (((
25 -"tx_lut_9": {
28 +**"tx_lut_9": {
26 26   "desc": "TX gain table, index 9",
27 27   "pa_gain": 2,
28 28   "mix_gain": 10,
29 29   "rf_power": 14,     ~-~-~-~-> Change this to 17 and will work.
30 30   "dig_gain": 0
31 -},
34 +},**
32 32  )))