From version < 97.1 >
edited by Kilight Cao
on 2024/07/12 09:36
To version < 99.1 >
edited by Kilight Cao
on 2024/07/12 13:58
>
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -505,34 +505,23 @@
505 505  * system Time synchronization Checking
506 506  * Auto update ( Software auto update, can be disabled)
507 507  
508 -=== 7.1.1 LoRaWAN Status push or polling data to LoRaWAN server ===
509 509  
509 +(% class="wikigeneratedid" %)
510 +=== 7.1.1 Uploading backup files to reduced data consumption ===
510 510  
511 -When gateway connect to LoRaWAN server via LoRaWAN protocol, besides the sensor data uplink/downlink. gateway will still need to:
512 512  
513 -* Uplink self-status to the LoRaWAN server every 30s. the users can adjust **Keep Alive Period** as below
514 -* Check LoRaWAN server status every 5 seconds to see if there is valid downlink command to sensors. We don't provide WEB UI option to modify this time, because the modify of this settings will lead to fail on OTAA Join and Downlink commands.
513 +Users can upload this backup file to reduce data consumption in **System~-~->Back Up/Restore Config**, Download link for backup file: **[[attach:Reduced_data_consumption.tar.gz||target="_blank"]]**
515 515  
516 -[[image:image-20220527155108-13.png]]
515 +[[image:image-20240712093532-1.png]]
517 517  
518 518  
519 -=== 7.1.2 System Keep Alive data ===
518 +=== 7.1.2 Auto update ===
520 520  
521 521  
522 -System Keep Alive Data is used to check gateway-network status and fix possible issue. Gateway will check every 15 seconds and generate traffic.
523 -
524 -Base on 15 seconds per check, the data traffic is about 2M data traffic per day. Users can adjust **Keepalive Interval** as below.
525 -
526 -[[image:image-20220527155229-15.png||height="511" width="986"]]
527 -
528 -
529 -=== 7.1.3 Auto update ===
530 -
531 -
532 532  Gateway will check for update every day for new configure or software. User can disable them by below method.
533 533  
534 534  
535 -=== 7.1.4 Filter unwanted packets ===
524 +=== 7.1.3 Filter unwanted packets ===
536 536  
537 537  
538 538  When gateway connect to LoRaWAN server via LoRaWAN protocol , Gateway will by default get every possible LoRaWAN packets and forward to LoRaWAN server. If there are sensors from others in the same area, such sensor data will also be forward to LoRaWAN server ( they will be ignore by the server). This also consume data.
Reduced_data_consumption.tar.gz
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Kilight
Size
... ... @@ -1,0 +1,1 @@
1 +10.4 KB
Content
Copyright ©2010-2022 Dragino Technology Co., LTD. All rights reserved
Dragino Wiki v2.0