Changes for page Notes for TTN
Last modified by Mengting Qiu on 2024/08/20 17:29
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -62,13 +62,9 @@ 62 62 63 63 === 2.2.2 Below list the support products and Requirements: === 64 64 65 -((( 66 -~1. LoRaWAN Gateway model: [[LIG16>>url:http://www.dragino.com/products/lora-lorawan-gateway/item/171-lig16.html]], [[LG308>>url:http://www.dragino.com/products/lora-lorawan-gateway/item/140-lg308.html]], [[DLOS8>>url:http://www.dragino.com/products/lora-lorawan-gateway/item/160-dlos8.html]] [[LPS8>>url:http://www.dragino.com/products/lora-lorawan-gateway/item/148-lps8.html]] 67 -))) 65 +1. LoRaWAN Gateway model: [[LIG16>>url:http://www.dragino.com/products/lora-lorawan-gateway/item/171-lig16.html]], [[LG308>>url:http://www.dragino.com/products/lora-lorawan-gateway/item/140-lg308.html]], [[DLOS8>>url:http://www.dragino.com/products/lora-lorawan-gateway/item/160-dlos8.html]] [[LPS8>>url:http://www.dragino.com/products/lora-lorawan-gateway/item/148-lps8.html]] 68 68 69 -((( 70 -2. Firmware version since :[[lgw~~-~~-build-v5.4.1644658774>>url:http://www.dragino.com/downloads/index.php?dir=LoRa_Gateway/LIG16/Firmware/Release/]] 71 -))) 67 +1. Firmware version since :[[lgw~~-~~-build-v5.4.1644658774>>url:http://www.dragino.com/downloads/index.php?dir=LoRa_Gateway/LIG16/Firmware/Release/]] 72 72 73 73 === 2.2.3 Example === 74 74 ... ... @@ -367,7 +367,7 @@ 367 367 368 368 ((( 369 369 ((( 370 - **Note**: Remember that the format of this topic for The Things Stack Open Source deployment would be v3/{application id}/devices/{device id}/down/push.366 +Note: Remember that the format of this topic for The Things Stack Open Source deployment would be v3/{application id}/devices/{device id}/down/push. 371 371 ))) 372 372 ))) 373 373 ... ... @@ -384,7 +384,7 @@ 384 384 ))) 385 385 386 386 ((( 387 - **Note**: Use this handy tool to convert hexadecimal to base64.383 +Note: Use this handy tool to convert hexadecimal to base64. 388 388 ))) 389 389 390 390 [[image:https://wiki.dragino.com/images/thumb/9/9f/V3_MQTT6.png/600px-V3_MQTT6.png||alt="V3 MQTT6.png" height="313" width="600"]] ... ... @@ -418,7 +418,7 @@ 418 418 ))) 419 419 420 420 ((( 421 - **Note**: If the downlink byte sent is longer, the number of bytes will be displayed.417 +Note: If the downlink byte sent is longer, the number of bytes will be displayed. 422 422 ))) 423 423 424 424 [[image:https://wiki.dragino.com/images/thumb/c/c9/Downlink_52.png/600px-Downlink_52.png||height="407" width="600"]] ... ... @@ -426,28 +426,20 @@ 426 426 downlink 427 427 428 428 ((( 429 -((( 430 430 If you want to get a successful reply to send downlink in TTN v3. You need to set the response level. 431 431 ))) 432 -))) 433 433 434 434 ((( 435 -((( 436 -If the equipment uses CLASS A. You can set **AT+RPL=2** or send the downlink command: **2102** 429 +If the equipment uses CLASS A. You can set AT+RPL=2 or send the downlink command: 2102 437 437 ))) 438 -))) 439 439 440 440 ((( 441 -((( 442 -If the equipment uses CLASS C. You can set** AT+RPL=4** or send the downlink command: **2104** 433 +If the equipment uses CLASS C. You can set AT+RPL=4 or send the downlink command: 2104 443 443 ))) 444 -))) 445 445 446 446 ((( 447 -((( 448 448 When the device successfully receives the downlink, the server will receive a confirmation packet of 00. 449 449 ))) 450 -))) 451 451 452 452 [[image:https://wiki.dragino.com/images/thumb/d/d9/Downlink_54.png/600px-Downlink_54.png||height="127" width="600"]] 453 453 ... ... @@ -457,7 +457,7 @@ 457 457 458 458 ((( 459 459 These pages are useful to check what is wrong on the Join process. Below shows the four steps that we can check the Join Process. 460 -\\If problem not solve, and you need dragino remote support, please follow to this document: [[TTN Support instruction>>url:https://www.dragino.com/downloads/index.php?dir=&file=TTNv3_Support_Guide.pdf]] (% style="color:red" %)**If user has checked below steps and still can't solve the problem, please send us (support @ dragino.com) the screenshots for each step to check. They include:**448 +\\If problem not solve, and you need dragino remote support, please follow to this document: [[TTN Support instruction>>url:https://www.dragino.com/downloads/index.php?dir=&file=TTNv3_Support_Guide.pdf]] If user has checked below steps and still can't solve the problem, please send us (support @ dragino.com) the screenshots for each step to check. They include: 461 461 ))) 462 462 463 463 * End node is connected to serial port to show the Join frequency and DR. (If possible) ... ... @@ -475,9 +475,9 @@ 475 475 476 476 Console Output from End device to see the transmit frequency 477 477 478 -User can run **AT+CFG**command to print configuration information.466 +User can run AT+CFG command to print configuration information. 479 479 480 -* Is the device in OTAA mode or ABP mode? **AT+NJM=1**(OTAA mode),**AT+NJM=0**(ABP mode)468 +* Is the device in OTAA mode or ABP mode? AT+NJM=1 (OTAA mode), AT+NJM=0 (ABP mode) 481 481 482 482 [[image:https://wiki.dragino.com/images/thumb/c/c5/LoRaWAN_Communication_Debug23.png/600px-LoRaWAN_Communication_Debug23.png||height="514" width="600"]] 483 483 ... ... @@ -485,12 +485,8 @@ 485 485 486 486 **2. Gateway packet traffic in gateway web or ssh. we can check:** 487 487 488 -* ((( 489 -If the gateway receive the Join request packet from sensor? (If this fail, check if the gateway and sensor works on the match frequency) 490 -))) 491 -* ((( 492 -If the gateway gets the Join Accept message from server and transmit it via LoRa? 493 -))) 476 +* If the gateway receive the Join request packet from sensor? (If this fail, check if the gateway and sensor works on the match frequency) 477 +* If the gateway gets the Join Accept message from server and transmit it via LoRa? 494 494 495 495 [[image:https://wiki.dragino.com/images/thumb/1/1c/OTAA_Join-2.png/600px-OTAA_Join-2.png||height="325" width="600"]] 496 496 ... ... @@ -522,11 +522,9 @@ 522 522 523 523 * ((( 524 524 ((( 525 -((( 526 526 If this data page shows the Join Request message from the end node? If not, most properly you have wrong settings in the keys. Keys in the server doesn't match the keys in End Node. 527 527 ))) 528 528 ))) 529 -))) 530 530 531 531 [[image:https://wiki.dragino.com/images/thumb/9/99/LoRaWAN_Communication_Debug4.png/600px-LoRaWAN_Communication_Debug4.png||height="222" width="600"]] 532 532