From version < 2.1 >
edited by Xiaoling
on 2022/05/17 09:20
To version < 1.12 >
edited by Xiaoling
on 2022/05/17 09:18
>
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -422,28 +422,20 @@
422 422  downlink
423 423  
424 424  (((
425 -(((
426 426  If you want to get a successful reply to send downlink in TTN v3. You need to set the response level.
427 427  )))
428 -)))
429 429  
430 430  (((
431 -(((
432 432  If the equipment uses CLASS A. You can set AT+RPL=2 or send the downlink command: 2102
433 433  )))
434 -)))
435 435  
436 436  (((
437 -(((
438 438  If the equipment uses CLASS C. You can set AT+RPL=4 or send the downlink command: 2104
439 439  )))
440 -)))
441 441  
442 442  (((
443 -(((
444 444  When the device successfully receives the downlink, the server will receive a confirmation packet of 00.
445 445  )))
446 -)))
447 447  
448 448  [[image:https://wiki.dragino.com/images/thumb/d/d9/Downlink_54.png/600px-Downlink_54.png||height="127" width="600"]]
449 449  
... ... @@ -453,7 +453,7 @@
453 453  
454 454  (((
455 455  These pages are useful to check what is wrong on the Join process. Below shows the four steps that we can check the Join Process.
456 -\\If problem not solve, and you need dragino remote support, please follow to this document: [[TTN Support instruction>>url:https://www.dragino.com/downloads/index.php?dir=&file=TTNv3_Support_Guide.pdf]](% style="color:red" %) **If user has checked below steps and still can't solve the problem, please send us (support @ dragino.com) the screenshots for each step to check. They include:**
448 +\\If problem not solve, and you need dragino remote support, please follow to this document: [[TTN Support instruction>>url:https://www.dragino.com/downloads/index.php?dir=&file=TTNv3_Support_Guide.pdf]] If user has checked below steps and still can't solve the problem, please send us (support @ dragino.com) the screenshots for each step to check. They include:
457 457  )))
458 458  
459 459  * End node is connected to serial port to show the Join frequency and DR. (If possible)
... ... @@ -481,12 +481,8 @@
481 481  
482 482  **2. Gateway packet traffic in gateway web or ssh. we can check:**
483 483  
484 -* (((
485 -If the gateway receive the Join request packet from sensor? (If this fail, check if the gateway and sensor works on the match frequency)
486 -)))
487 -* (((
488 -If the gateway gets the Join Accept message from server and transmit it via LoRa?
489 -)))
476 +* If the gateway receive the Join request packet from sensor? (If this fail, check if the gateway and sensor works on the match frequency)
477 +* If the gateway gets the Join Accept message from server and transmit it via LoRa?
490 490  
491 491  [[image:https://wiki.dragino.com/images/thumb/1/1c/OTAA_Join-2.png/600px-OTAA_Join-2.png||height="325" width="600"]]
492 492  
Copyright ©2010-2024 Dragino Technology Co., LTD. All rights reserved
Dragino Wiki v2.0