Changes for page Notes for TTN
Last modified by Mengting Qiu on 2024/08/20 17:29
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -62,9 +62,13 @@ 62 62 63 63 === 2.2.2 Below list the support products and Requirements: === 64 64 65 -1. LoRaWAN Gateway model: [[LIG16>>url:http://www.dragino.com/products/lora-lorawan-gateway/item/171-lig16.html]], [[LG308>>url:http://www.dragino.com/products/lora-lorawan-gateway/item/140-lg308.html]], [[DLOS8>>url:http://www.dragino.com/products/lora-lorawan-gateway/item/160-dlos8.html]] [[LPS8>>url:http://www.dragino.com/products/lora-lorawan-gateway/item/148-lps8.html]] 65 +((( 66 +~1. LoRaWAN Gateway model: [[LIG16>>url:http://www.dragino.com/products/lora-lorawan-gateway/item/171-lig16.html]], [[LG308>>url:http://www.dragino.com/products/lora-lorawan-gateway/item/140-lg308.html]], [[DLOS8>>url:http://www.dragino.com/products/lora-lorawan-gateway/item/160-dlos8.html]] [[LPS8>>url:http://www.dragino.com/products/lora-lorawan-gateway/item/148-lps8.html]] 67 +))) 66 66 67 -1. Firmware version since :[[lgw~~-~~-build-v5.4.1644658774>>url:http://www.dragino.com/downloads/index.php?dir=LoRa_Gateway/LIG16/Firmware/Release/]] 69 +((( 70 +2. Firmware version since :[[lgw~~-~~-build-v5.4.1644658774>>url:http://www.dragino.com/downloads/index.php?dir=LoRa_Gateway/LIG16/Firmware/Release/]] 71 +))) 68 68 69 69 === 2.2.3 Example === 70 70 ... ... @@ -356,16 +356,22 @@ 356 356 [[image:https://wiki.dragino.com/images/thumb/e/e8/V3_MQTT4.jpg/600px-V3_MQTT4.jpg||alt="V3 MQTT4.jpg" height="326" width="600"]] 357 357 358 358 ((( 363 +((( 359 359 Downlinks can be scheduled by publishing the message to the topic v3/{application id}@{tenant id}/devices/{device id}/down/push. 360 360 ))) 366 +))) 361 361 362 362 ((( 363 -Note: Remember that the format of this topic for The Things Stack Open Source deployment would be v3/{application id}/devices/{device id}/down/push. 369 +((( 370 +**Note**: Remember that the format of this topic for The Things Stack Open Source deployment would be v3/{application id}/devices/{device id}/down/push. 364 364 ))) 372 +))) 365 365 366 366 ((( 375 +((( 367 367 Instead of /push, you can also use /replace to replace the downlink queue. Replacing with an empty array clears the downlink queue. Example: 368 368 ))) 378 +))) 369 369 370 370 [[image:https://wiki.dragino.com/images/thumb/e/e8/V3_MQTT5.png/600px-V3_MQTT5.png||alt="V3 MQTT5.png" height="289" width="600"]] 371 371 ... ... @@ -374,7 +374,7 @@ 374 374 ))) 375 375 376 376 ((( 377 -Note: Use this handy tool to convert hexadecimal to base64. 387 +**Note**: Use this handy tool to convert hexadecimal to base64. 378 378 ))) 379 379 380 380 [[image:https://wiki.dragino.com/images/thumb/9/9f/V3_MQTT6.png/600px-V3_MQTT6.png||alt="V3 MQTT6.png" height="313" width="600"]] ... ... @@ -408,7 +408,7 @@ 408 408 ))) 409 409 410 410 ((( 411 -Note: If the downlink byte sent is longer, the number of bytes will be displayed. 421 +**Note**: If the downlink byte sent is longer, the number of bytes will be displayed. 412 412 ))) 413 413 414 414 [[image:https://wiki.dragino.com/images/thumb/c/c9/Downlink_52.png/600px-Downlink_52.png||height="407" width="600"]] ... ... @@ -416,20 +416,28 @@ 416 416 downlink 417 417 418 418 ((( 429 +((( 419 419 If you want to get a successful reply to send downlink in TTN v3. You need to set the response level. 420 420 ))) 432 +))) 421 421 422 422 ((( 423 -If the equipment uses CLASS A. You can set AT+RPL=2 or send the downlink command: 2102 435 +((( 436 +If the equipment uses CLASS A. You can set **AT+RPL=2** or send the downlink command: **2102** 424 424 ))) 438 +))) 425 425 426 426 ((( 427 -If the equipment uses CLASS C. You can set AT+RPL=4 or send the downlink command: 2104 441 +((( 442 +If the equipment uses CLASS C. You can set** AT+RPL=4** or send the downlink command: **2104** 428 428 ))) 444 +))) 429 429 430 430 ((( 447 +((( 431 431 When the device successfully receives the downlink, the server will receive a confirmation packet of 00. 432 432 ))) 450 +))) 433 433 434 434 [[image:https://wiki.dragino.com/images/thumb/d/d9/Downlink_54.png/600px-Downlink_54.png||height="127" width="600"]] 435 435 ... ... @@ -439,7 +439,7 @@ 439 439 440 440 ((( 441 441 These pages are useful to check what is wrong on the Join process. Below shows the four steps that we can check the Join Process. 442 -\\If problem not solve, and you need dragino remote support, please follow to this document: [[TTN Support instruction>>url:https://www.dragino.com/downloads/index.php?dir=&file=TTNv3_Support_Guide.pdf]] If user has checked below steps and still can't solve the problem, please send us (support @ dragino.com) the screenshots for each step to check. They include: 460 +\\If problem not solve, and you need dragino remote support, please follow to this document: [[TTN Support instruction>>url:https://www.dragino.com/downloads/index.php?dir=&file=TTNv3_Support_Guide.pdf]](% style="color:red" %) **If user has checked below steps and still can't solve the problem, please send us (support @ dragino.com) the screenshots for each step to check. They include:** 443 443 ))) 444 444 445 445 * End node is connected to serial port to show the Join frequency and DR. (If possible) ... ... @@ -457,9 +457,9 @@ 457 457 458 458 Console Output from End device to see the transmit frequency 459 459 460 -User can run AT+CFG command to print configuration information. 478 +User can run **AT+CFG **command to print configuration information. 461 461 462 -* Is the device in OTAA mode or ABP mode? AT+NJM=1 (OTAA mode), AT+NJM=0 (ABP mode) 480 +* Is the device in OTAA mode or ABP mode? **AT+NJM=1** (OTAA mode), **AT+NJM=0** (ABP mode) 463 463 464 464 [[image:https://wiki.dragino.com/images/thumb/c/c5/LoRaWAN_Communication_Debug23.png/600px-LoRaWAN_Communication_Debug23.png||height="514" width="600"]] 465 465 ... ... @@ -467,8 +467,12 @@ 467 467 468 468 **2. Gateway packet traffic in gateway web or ssh. we can check:** 469 469 470 -* If the gateway receive the Join request packet from sensor? (If this fail, check if the gateway and sensor works on the match frequency) 471 -* If the gateway gets the Join Accept message from server and transmit it via LoRa? 488 +* ((( 489 +If the gateway receive the Join request packet from sensor? (If this fail, check if the gateway and sensor works on the match frequency) 490 +))) 491 +* ((( 492 +If the gateway gets the Join Accept message from server and transmit it via LoRa? 493 +))) 472 472 473 473 [[image:https://wiki.dragino.com/images/thumb/1/1c/OTAA_Join-2.png/600px-OTAA_Join-2.png||height="325" width="600"]] 474 474 ... ... @@ -477,9 +477,15 @@ 477 477 478 478 **3. Gateway Traffic Page in LoRaWAN Server** 479 479 480 -* If the Join Request packet arrive the gateway traffic in server? If not, check the internet connection and gateway LoRaWAN server settings. 481 -* If the server send back a Join Accept for the Join Request? if not, check if the keys from the device match the keys you put in the server, or try to choose a different server route for this end device. 482 -* If the Join Accept message are in correct frequency? If you set the server to use US915 band, and your end node and gateway is EU868, you will see the Join Accept message are in US915 band so no possible to Join success. 502 +* ((( 503 +If the Join Request packet arrive the gateway traffic in server? If not, check the internet connection and gateway LoRaWAN server settings. 504 +))) 505 +* ((( 506 +If the server send back a Join Accept for the Join Request? if not, check if the keys from the device match the keys you put in the server, or try to choose a different server route for this end device. 507 +))) 508 +* ((( 509 +If the Join Accept message are in correct frequency? If you set the server to use US915 band, and your end node and gateway is EU868, you will see the Join Accept message are in US915 band so no possible to Join success. 510 +))) 483 483 484 484 [[image:https://wiki.dragino.com/images/thumb/d/da/LoRaWAN_Communication_Debug22.png/600px-LoRaWAN_Communication_Debug22.png||height="268" width="600"]] 485 485 ... ... @@ -493,8 +493,12 @@ 493 493 **4. Data Page in LoRaWAN server** 494 494 495 495 * ((( 524 +((( 525 +((( 496 496 If this data page shows the Join Request message from the end node? If not, most properly you have wrong settings in the keys. Keys in the server doesn't match the keys in End Node. 497 497 ))) 528 +))) 529 +))) 498 498 499 499 [[image:https://wiki.dragino.com/images/thumb/9/99/LoRaWAN_Communication_Debug4.png/600px-LoRaWAN_Communication_Debug4.png||height="222" width="600"]] 500 500