Changes for page Notes for TTN
Last modified by Mengting Qiu on 2024/08/20 17:29
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -422,20 +422,28 @@ 422 422 downlink 423 423 424 424 ((( 425 +((( 425 425 If you want to get a successful reply to send downlink in TTN v3. You need to set the response level. 426 426 ))) 428 +))) 427 427 428 428 ((( 431 +((( 429 429 If the equipment uses CLASS A. You can set AT+RPL=2 or send the downlink command: 2102 430 430 ))) 434 +))) 431 431 432 432 ((( 437 +((( 433 433 If the equipment uses CLASS C. You can set AT+RPL=4 or send the downlink command: 2104 434 434 ))) 440 +))) 435 435 436 436 ((( 443 +((( 437 437 When the device successfully receives the downlink, the server will receive a confirmation packet of 00. 438 438 ))) 446 +))) 439 439 440 440 [[image:https://wiki.dragino.com/images/thumb/d/d9/Downlink_54.png/600px-Downlink_54.png||height="127" width="600"]] 441 441 ... ... @@ -445,7 +445,7 @@ 445 445 446 446 ((( 447 447 These pages are useful to check what is wrong on the Join process. Below shows the four steps that we can check the Join Process. 448 -\\If problem not solve, and you need dragino remote support, please follow to this document: [[TTN Support instruction>>url:https://www.dragino.com/downloads/index.php?dir=&file=TTNv3_Support_Guide.pdf]] If user has checked below steps and still can't solve the problem, please send us (support @ dragino.com) the screenshots for each step to check. They include: 456 +\\If problem not solve, and you need dragino remote support, please follow to this document: [[TTN Support instruction>>url:https://www.dragino.com/downloads/index.php?dir=&file=TTNv3_Support_Guide.pdf]](% style="color:red" %) **If user has checked below steps and still can't solve the problem, please send us (support @ dragino.com) the screenshots for each step to check. They include:** 449 449 ))) 450 450 451 451 * End node is connected to serial port to show the Join frequency and DR. (If possible) ... ... @@ -473,8 +473,12 @@ 473 473 474 474 **2. Gateway packet traffic in gateway web or ssh. we can check:** 475 475 476 -* If the gateway receive the Join request packet from sensor? (If this fail, check if the gateway and sensor works on the match frequency) 477 -* If the gateway gets the Join Accept message from server and transmit it via LoRa? 484 +* ((( 485 +If the gateway receive the Join request packet from sensor? (If this fail, check if the gateway and sensor works on the match frequency) 486 +))) 487 +* ((( 488 +If the gateway gets the Join Accept message from server and transmit it via LoRa? 489 +))) 478 478 479 479 [[image:https://wiki.dragino.com/images/thumb/1/1c/OTAA_Join-2.png/600px-OTAA_Join-2.png||height="325" width="600"]] 480 480