From version < 1.12 >
edited by Xiaoling
on 2022/05/17 09:18
To version < 1.14 >
edited by Xiaoling
on 2022/05/17 09:20
>
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -422,20 +422,28 @@
422 422  downlink
423 423  
424 424  (((
425 +(((
425 425  If you want to get a successful reply to send downlink in TTN v3. You need to set the response level.
426 426  )))
428 +)))
427 427  
428 428  (((
431 +(((
429 429  If the equipment uses CLASS A. You can set AT+RPL=2 or send the downlink command: 2102
430 430  )))
434 +)))
431 431  
432 432  (((
437 +(((
433 433  If the equipment uses CLASS C. You can set AT+RPL=4 or send the downlink command: 2104
434 434  )))
440 +)))
435 435  
436 436  (((
443 +(((
437 437  When the device successfully receives the downlink, the server will receive a confirmation packet of 00.
438 438  )))
446 +)))
439 439  
440 440  [[image:https://wiki.dragino.com/images/thumb/d/d9/Downlink_54.png/600px-Downlink_54.png||height="127" width="600"]]
441 441  
... ... @@ -445,7 +445,7 @@
445 445  
446 446  (((
447 447  These pages are useful to check what is wrong on the Join process. Below shows the four steps that we can check the Join Process.
448 -\\If problem not solve, and you need dragino remote support, please follow to this document: [[TTN Support instruction>>url:https://www.dragino.com/downloads/index.php?dir=&file=TTNv3_Support_Guide.pdf]] If user has checked below steps and still can't solve the problem, please send us (support @ dragino.com) the screenshots for each step to check. They include:
456 +\\If problem not solve, and you need dragino remote support, please follow to this document: [[TTN Support instruction>>url:https://www.dragino.com/downloads/index.php?dir=&file=TTNv3_Support_Guide.pdf]](% style="color:red" %) **If user has checked below steps and still can't solve the problem, please send us (support @ dragino.com) the screenshots for each step to check. They include:**
449 449  )))
450 450  
451 451  * End node is connected to serial port to show the Join frequency and DR. (If possible)
... ... @@ -473,8 +473,12 @@
473 473  
474 474  **2. Gateway packet traffic in gateway web or ssh. we can check:**
475 475  
476 -* If the gateway receive the Join request packet from sensor? (If this fail, check if the gateway and sensor works on the match frequency)
477 -* If the gateway gets the Join Accept message from server and transmit it via LoRa?
484 +* (((
485 +If the gateway receive the Join request packet from sensor? (If this fail, check if the gateway and sensor works on the match frequency)
486 +)))
487 +* (((
488 +If the gateway gets the Join Accept message from server and transmit it via LoRa?
489 +)))
478 478  
479 479  [[image:https://wiki.dragino.com/images/thumb/1/1c/OTAA_Join-2.png/600px-OTAA_Join-2.png||height="325" width="600"]]
480 480  
Copyright ©2010-2024 Dragino Technology Co., LTD. All rights reserved