From version < 86.1 >
edited by Bei Jinggeng
on 2022/06/17 14:01
To version < 88.6 >
edited by Xiaoling
on 2022/07/23 14:38
>
Change comment: There is no comment for this version

Summary

Details

Page properties
Author
... ... @@ -1,1 +1,1 @@
1 -XWiki.Bei
1 +XWiki.Xiaoling
Content
... ... @@ -1,4 +1,4 @@
1 -**~ Contents:**
1 +**~ Table of Contents:**
2 2  
3 3  {{toc/}}
4 4  
... ... @@ -5,10 +5,11 @@
5 5  
6 6  
7 7  
8 -= **1. Use Dragino Gateways/Hotspots with Helium** =
8 += **1.  Use Dragino Gateways/Hotspots with Helium** =
9 9  
10 -== **1.1 Support Models** ==
10 +== **1.1  Support Models** ==
11 11  
12 +
12 12  //There are three types of hotspots that can connect to Helium. They are (% style="color:#4f81bd" %)**full-hotspot**(%%), (% style="color:#4f81bd" %)**light hotspot** (%%)and (% style="color:#4f81bd" %)**data-only hotspot**(%%). Definition of these three types of hotspots can be found here: [[of Helium Hotspots>>url:https://docs.helium.com/mine-hnt%7CTypes]]. Different hotspots support different mining abilities.//
13 13  
14 14  (((
... ... @@ -29,27 +29,32 @@
29 29  
30 30  * //The frequencies currently available are CN470/EU868/US915/AU915//
31 31  
33 +
32 32  (% style="color:red" %)**Note: more information refer to this link [[Helium Frequency plan>>url:https://docs.helium.com/lorawan-on-helium/frequency-plans/]]**
33 33  
34 34  
35 -= **2. Connect Data-Only Hotspot to Helium** =
36 36  
37 -== **2.1 Prerequisites** ==
38 += **2.  Connect Data-Only Hotspot to Helium** =
38 38  
40 +== **2.1  Prerequisites** ==
39 39  
42 +
40 40  * //Firmware Requirement: > [[lgw~~-~~-build-v5.4.1640315898>>url:https://www.dragino.com/downloads/index.php?dir=LoRa_Gateway/LPS8/Firmware/Release/]]//
41 41  
42 -== **2.2 Step 1: Configure Frequency Band** ==
43 43  
44 44  
47 +== **2.2  Step 1: Configure Frequency Band** ==
48 +
49 +
45 45  //Each country has a requirement for frequency region. Choose the right one for your area.//
46 46  
47 47  [[image:image-20220531175337-1.png]]
48 48  
49 49  
50 -== **2.3 Step 2: Download the Helium-gateway-rs** ==
51 51  
56 +== **2.3  Step 2: Download the Helium-gateway-rs** ==
52 52  
58 +
53 53  //Click Download Helium Server and the gateway will download the Helium-gateway-rs//
54 54  
55 55  [[image:image-20220615150600-1.png||height="559" width="1045"]]
... ... @@ -67,7 +67,7 @@
67 67  [[image:image-20220615150717-3.png||height="605" width="1039"]]
68 68  
69 69  
70 -== **2.4 Step 3: Install the Helium-gateway-rs** ==
76 +== **2.4  Step 3: Install the Helium-gateway-rs** ==
71 71  
72 72  
73 73  //Click **Install Helium Server** to install gateway-rs.//
... ... @@ -76,25 +76,28 @@
76 76  
77 77  Install the Helium gateway-rs
78 78  
85 +
79 79  (% style="color:red" %)**Note: User will see the echo characters of Helium gateway-rs have been installed successfully.**
80 80  
81 81  
82 -== **2.5 Step 4: Save&start the Helium Server** ==
83 83  
90 +== **2.5  Step 4: Save&start the Helium Server** ==
84 84  
92 +
85 85  //By default, Region is US915, After configuring the Configure Frequency Band, click Save&Apply on the Helium IoT screen to modify the Region.//
86 86  
87 87  [[image:image-20220615150903-5.png||height="592" width="1031"]]
88 88  
89 89  
90 -//Click **Save&Apply** and gateway will start to connect the Helium. The UI shows the connect status.//
98 +//Click (% style="color:red" %)**Save&Apply**(%%) and gateway will start to connect the Helium. The UI shows the connect status.//
91 91  
92 92  [[image:image-20220615151057-6.png||height="580" width="1026"]]
93 93  
94 94  
95 -== **2.6 Step 5: Check Gateway Connection before onboarding** ==
96 96  
104 +== **2.6  Step 5: Check Gateway Connection before onboarding** ==
97 97  
106 +
98 98  //A hotspot can transfer data to Helium after finishing step4. We can add a device to Helium and see if the device can join Helium. For example, we add an LGT92 sensor and see below info.//
99 99  
100 100  (((
... ... @@ -109,7 +109,7 @@
109 109  
110 110  == 2.7 Step 6: Onboarding Data-Only Hotspot ==
111 111  
112 -(% style="color:red" %)**Note: Onboarding a Data-Only hotspot is not necessary, and it will gain very, very small awards on HNT by data-transfer .**
121 +(% style="color:red" %)**Note: Onboarding a Data-Only hotspot is necessary for downlink to work. otherwise, the downlink message for LoRa won't work .**
113 113  
114 114  //User can refer [[this link>>url:https://docs.helium.com/mine-hnt/data-only-hotspots]] for how to onboarding a data-only hotspot. After onboarding the data-only hotspot, user can see the hotspot on Helium Console.//
115 115  
... ... @@ -637,7 +637,7 @@
637 637  )))
638 638  
639 639  * (((
640 -//Example:AT+CHE=1 ~/~/set channel mode to 1//
649 +//Example:**AT+CHE=2** ~/~/set channel mode to 1//
641 641  )))
642 642  
643 643  * (((
... ... @@ -649,15 +649,12 @@
649 649  )))
650 650  
651 651  (((
652 -//If the downlink payload=2401, it means set channel mode to 1, while type code is 24.//
661 +//If the downlink payload=0x2402, it means set channel mode to use sub-band 2, while type code is 24.//
653 653  )))
654 654  
655 655  * (((
656 -//Example 1: Downlink Payload: 2401 ~/~/ set channel mode to 1//
657 -)))
665 +//Example 1: Downlink Payload: **0x2402** ~/~/ set channel mode to 2//
658 658  
659 -* (((
660 -//Example 2: Downlink Payload: 2405 ~/~/ set channel mode to 5//
661 661  
662 662  
663 663  )))
Copyright ©2010-2024 Dragino Technology Co., LTD. All rights reserved
Dragino Wiki v2.0