<
From version < 19.1 >
edited by Edwin Chen
on 2022/05/25 15:42
To version < 11.1 >
edited by Edwin Chen
on 2022/05/25 15:26
>
Change comment: There is no comment for this version

Summary

Details

Page properties
Title
... ... @@ -1,1 +1,1 @@
1 -Node-RED_Install and Use
1 +nodered_Install and Use
Content
... ... @@ -1,16 +6,10 @@
1 -(% class="wikigeneratedid" id="HEndDeviceFrequencyBand" %)
2 - **Contents:**
3 -
4 -{{toc/}}
5 -
6 6  = Installation =
7 7  
8 8  Check installation instruction for different OS from this link: [[https:~~/~~/nodered.org/docs/getting-started/>>https://nodered.org/docs/getting-started/]]
9 9  
5 +(% class="wikigeneratedid" %)
10 10  == Install Example for CENTOS ==
11 11  
12 -=== Installation ===
13 -
14 14  (% class="box infomessage" %)
15 15  (((
16 16  Reference Instruction from this link: ~_~_~_~_~_~_~_~_~_~_~_~_~_~__-
... ... @@ -27,28 +27,8 @@
27 27  
28 28  [[image:image-20220519103318-3.png]]
29 29  
24 +== Login to nodered interface ==
30 30  
31 -=== If you want to start Node-RED as a background process ===
32 -
33 -Type in the command line interface  nohup node-red &
34 -
35 -It will prompt after startup
36 -
37 -[[image:image-20220519104601-5.png]]
38 -
39 -After seeing the above information, press enter
40 -
41 -Type in the command line  exit
42 -
43 -The above is the installation and startup process of nodered. If you don't understand anything, you can go to the nodered official website. There are installation instructions for various systems. The address has a link at the top
44 -
45 -== Install in Dragino Gataway ==
46 -
47 -
48 -= Use Node-RED =
49 -
50 -== Login to Node-RED interface ==
51 -
52 52  Enter your public IP address followed by the port number 1880
53 53  
54 54  example:[[http:~~/~~/xxx.xx.xx.xx:1880/>>http://119.91.62.30:1880/]]
... ... @@ -56,27 +56,16 @@
56 56  [[image:image-20220519104115-4.png]]
57 57  
58 58  
59 -== Add Sensor & Payload ==
33 +== If you want to start nodered as a background process ==
60 60  
35 +Type in the command line interface  nohup node-red &
61 61  
62 -== Plot Chart for sensors ==
37 +It will prompt after startup
63 63  
39 +[[image:image-20220519104601-5.png]]
64 64  
65 -== Store Value ==
41 +After seeing the above information, press enter
66 66  
43 +Type in the command line  exit
67 67  
68 -== Email Notification ==
69 -
70 -
71 -= Input Data Flow =
72 -
73 -== MQTT ==
74 -
75 -== UDP ==
76 -
77 -== TCP ==
78 -
79 -== Get data from LoRaWAN Server (TTN) ==
80 -
81 -
82 -= Example =
45 +The above is the installation and startup process of nodered. If you don't understand anything, you can go to the nodered official website. There are installation instructions for various systems. The address has a link at the top
LHT65N-chirpstack decoder.txt
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Edwin
Size
... ... @@ -1,1 +1,0 @@
1 -1.7 KB
Content
... ... @@ -1,66 +1,0 @@
1 -function Decode(fPort, bytes){
2 -var data = {
3 - //External sensor
4 - Ext_sensor:
5 - {
6 - "0":"No external sensor",
7 - "1":"Temperature Sensor",
8 - "4":"Interrupt Sensor send",
9 - "5":"Illumination Sensor",
10 - "6":"ADC Sensor",
11 - "7":"Interrupt Sensor count",
12 - }[bytes[6]&0x7F],
13 -
14 - //Battery,units:V
15 - BatV:((bytes[0]<<8 | bytes[1]) & 0x3FFF)/1000,
16 -
17 - //SHT20,temperature,units:
18 - TempC_SHT:((bytes[2]<<24>>16 | bytes[3])/100).toFixed(2),
19 -
20 - //SHT20,Humidity,units:%
21 - Hum_SHT:((bytes[4]<<8 | bytes[5])/10).toFixed(1),
22 -
23 - //DS18B20,temperature,units:
24 - TempC_DS:
25 - {
26 - "1":((bytes[7]<<24>>16 | bytes[8])/100).toFixed(2),
27 - }[bytes[6]&0xFF],
28 -
29 - //Exti pin level,PA4
30 - Exti_pin_level:
31 - {
32 - "4":bytes[7] ? "High":"Low",
33 - }[bytes[6]&0x7F],
34 -
35 - //Exit pin status,PA4
36 - Exti_status:
37 - {
38 - "4":bytes[8] ? "True":"False",
39 - }[bytes[6]&0x7F],
40 -
41 - //BH1750,illumination,units:lux
42 - ILL_lux:
43 - {
44 - "5":bytes[7]<<8 | bytes[8],
45 - }[bytes[6]&0x7F],
46 -
47 - //ADC,PA4,units:V
48 - ADC_V:
49 - {
50 - "6":(bytes[7]<<8 | bytes[8])/1000,
51 - }[bytes[6]&0x7F],
52 -
53 - //Exti count,PA4,units:times
54 - Exit_count:
55 - {
56 - "7":bytes[7]<<8 | bytes[8],
57 - }[bytes[6]&0x7F],
58 -
59 - //Applicable to working mode 4567,and working mode 467 requires short circuit PA9 and PA10
60 - No_connect:
61 - {
62 - "1":"Sensor no connection",
63 - }[(bytes[6]&0x80)>>7],
64 - };
65 - return data;
66 -}
Copyright ©2010-2022 Dragino Technology Co., LTD. All rights reserved
Dragino Wiki v2.0