Changes for page Monitor & Remote Access Gateway
Last modified by Kilight Cao on 2025/01/14 10:25
Summary
-
Page properties (2 modified, 0 added, 0 removed)
-
Attachments (0 modified, 0 added, 6 removed)
Details
- Page properties
-
- Author
-
... ... @@ -1,1 +1,1 @@ 1 -XWiki.Xiao ling1 +XWiki.Xiaoye - Content
-
... ... @@ -5,9 +5,9 @@ 5 5 6 6 7 7 8 -= 1. Monitor Gateway = 8 += **1. Monitor Gateway** = 9 9 10 -== 1.1 Introduction == 10 +== **1.1 Introduction** == 11 11 12 12 13 13 This introduction shows how to use a script to monitor the gateway. The video link for this instruction is: [[https:~~/~~/youtu.be/8PieIwfSF_g>>url:https://youtu.be/8PieIwfSF_g]] ... ... @@ -16,9 +16,10 @@ 16 16 [[image:image-20220531155018-18.png]] 17 17 18 18 19 -== 1.2 Steps == 20 20 20 +== **1.2 Steps** == 21 21 22 + 22 22 * Create account in ThingsSpeak and creat channel. 23 23 * Download script from dragino site and move it to properly directory 24 24 ... ... @@ -71,11 +71,9 @@ 71 71 72 72 * Reboot device. 73 73 75 +== **1.3 Monitor Public IP** == 74 74 75 75 76 -== 1.3 Monitor Public IP == 77 - 78 - 79 79 The monitor_gateway.sh has been updated to upload the public ip of the device as well. 80 80 81 81 User can find the public ip in field7, the chart is not able to show the complete public ip, user can check that in the export. ... ... @@ -86,11 +86,12 @@ 86 86 Find Public IP 87 87 88 88 89 -= 2. Remote Access = 90 90 91 -= =2.1Remote Accessvia Remote.it.==89 += **2. Remote Access** = 92 92 91 += **2.1 Remote Access via Remote.it.** = 93 93 93 + 94 94 Remote.it for remote access is available in the latest Dragino firmware for gateway. For security concern, the remote.it only available base on end user demand. 95 95 96 96 ... ... @@ -98,6 +98,7 @@ 98 98 99 99 * Remote.it access will give full control of your device to remote support. 100 100 * The Remote.it allows Dragino Support to remote access to the device, If user want to access himself, it need to sign up for an remote.it account. 101 + 101 101 * For how to use remote.it for (% style="color:blue" %)**general remote control**(%%), please see : [[Remoteit user instruction for Dragino Gateway>>https://www.remote.it/getting-started/dragino]]. 102 102 * For Quick add remote.it to (% style="color:blue" %)**Dragino for remote debug**(%%), please see below: 103 103 ... ... @@ -119,7 +119,7 @@ 119 119 120 120 (% class="box infomessage" %) 121 121 ((( 122 -** fd173d1d-faed-493e-a868-c511a38aba45**123 +**57F60715-606F-510D-A3D2-739860EBDB98** 123 123 ))) 124 124 125 125 [[image:image-20220725113010-1.png||height="455" width="899"]] ... ... @@ -134,8 +134,8 @@ 134 134 [[image:image-20220725115720-2.png||height="658" width="900"]] 135 135 136 136 137 -=== 2.1.1 How to save the registered remote after the gateway's firmware update. === 138 138 139 +== **How to save the registered remote after the gateway's firmware update.** == 139 139 140 140 Before version [[lgw~~-~~-build-v5.4.1668240318-20221112-1606>>http://repo.dragino.com/release/miscellaneous/remoteit/dragino-lgw--v5.4.1668240318-squashfs-sysupgrade.bin]], once the gateway firmware is upgraded the remote configuration is gone. 141 141 ... ... @@ -142,44 +142,41 @@ 142 142 This issue is now corrected: 143 143 144 144 146 +=== The gateway version is lower than **lgw~-~-build-v5.4.1668240318-20221112-1606:** === 145 145 146 - ====**Thegateway version iswer than** **lgw~-~-build-v5.4.1668240318-20221112-1606:** ====148 +~1. upload the [[backup file>>http://repo.dragino.com/release/miscellaneous/remoteit/backup.tar.gz]] to update the configuration. 147 147 148 148 149 -**~1. upload the [[backup file>>http://repo.dragino.com/release/miscellaneous/remoteit/backup.tar.gz]] to update the configuration.** 150 - 151 151 [[image:image-20221112162644-4.png]] 152 152 153 +2. Check the 'Preserver Settings' check box when you upgrade the gateway with the firmware. 153 153 154 154 155 -**2. Check the 'Preserver Settings' check box when you upgrade the gateway with the firmware. ** 156 - 157 157 [[image:image-20221112162543-2.png]] 158 158 159 159 159 +=== The gateway version is greater or equal to **lgw~-~-build-v5.4.1668240318-20221112-1606:** === 160 160 161 -==== **The gateway version is greater or equal to** **lgw~-~-build-v5.4.1668240318-20221112-1606:** ==== 162 162 162 +~1. Only to do: Check the 'Preserver Settings' check box when you upgrade the gateway with the firmware. 163 163 164 164 165 -**~1. Only to do: Check the 'Preserver Settings' check box when you upgrade the gateway with the firmware. ** 166 - 167 167 [[image:image-20221112162547-3.png]] 168 168 169 169 170 -== 2.1.2 How to register hp0d with Remote.it == 171 171 169 +== **2.1.1 How to register hp0d with Remote.it** == 172 172 171 + 173 173 **Prerequisites:** 174 174 175 175 Users must have an account and APP for remote.it 176 176 177 - **[[https:~~/~~/app.remote.it>>https://app.remote.it]]**176 +[[https:~~/~~/app.remote.it>>https://app.remote.it]] 178 178 179 179 180 180 === (% style="color:blue" %)**1. Click "+" in the APP to add a device**(%%) === 181 181 182 - 183 183 Then click Add "Linux & Raspberry Pi" and the APP will generate a command to register the device. 184 184 185 185 ... ... @@ -207,46 +207,10 @@ 207 207 [[image:image-20220815173958-4.jpeg||height="580" width="964"]] 208 208 209 209 210 -== 2.1.3 How to register the gateway with Remote.it via SSH Access for Linux console == 211 211 209 +== **2.1.2 Trouble Shooting** == 212 212 213 -**Prerequisites:** 214 214 215 -Users must have an account and APP for remote.it 216 - 217 -**[[https:~~/~~/app.remote.it>>https://app.remote.it]]** 218 - 219 -For detailed examples, please see: **[[OpenWrt How to Connect Guide (remote.it)>>url:https://www.remote.it/getting-started/openwrt]]** 220 - 221 - 222 -=== (% style="color:blue" %)**1. Click "+" in the APP to add a device**(%%) === 223 - 224 - 225 -Then click Add "OpenWrt" and the APP will generate a command to register the device. 226 - 227 -[[image:image-20230320110123-4.png||height="657" width="1191"]] 228 - 229 - 230 -=== (% style="color:blue" %)**2. Copy the register device command**(%%) === 231 - 232 - 233 -[[image:image-20230320110309-5.png||height="635" width="1197"]] 234 - 235 - 236 -=== (% style="color:blue" %)**3. Enter the command copied from the previous step on the gateway Linux command line**(%%) === 237 - 238 -=== [[image:image-20230320105212-1.png||height="758" width="820"]] === 239 - 240 - 241 -=== (% style="color:blue" %)**4. Check whether the device is successfully registered on the Remote.it APP**(%%) === 242 - 243 - 244 -[[image:image-20230320112057-6.png||height="603" width="1135"]] 245 - 246 - 247 -== 2.1.4 Trouble Shooting == 248 - 249 - 250 250 === **1. What should users do when gateway Remote.it installation fails** === 251 251 252 252 ... ... @@ -268,7 +268,7 @@ 268 268 269 269 270 270 271 -= 2.2 RSSH Introduction = 233 += **2.2 RSSH Introduction** = 272 272 273 273 274 274 Reverse SSH for remote access is available in the latest Dragino firmware for gateway. For security concern, the RSSH only available base on end user demand. ... ... @@ -292,7 +292,7 @@ 292 292 * LIG16 293 293 * MS14 series if installed with the same firmware. 294 294 295 -=== 2.2.1 End User Guide to use SSH access === 257 +=== **2.2.1 End User Guide to use SSH access** === 296 296 297 297 298 298 Go to this the Reverse SSH page as below: ... ... @@ -319,7 +319,7 @@ 319 319 320 320 321 321 322 -=== 2.2.2 Set Up RSSH Server === 284 +=== **2.2.2 Set Up RSSH Server** === 323 323 324 324 325 325 Advance administrator can config a SSH server to provide support their end user themselves., Steps as below ... ... @@ -453,10 +453,11 @@ 453 453 {{{ check: sudo ls /home/xxxxx/.ssh/authorizedkey}}} 454 454 455 455 456 -=== 2.2.3 How does user get the gateway to connect to a user's private server === 457 457 419 +=== **2.2.3 How does user get the gateway to connect to a user's private server** === 458 458 459 459 422 + 460 460 ==== (% style="color:blue" %)**Step 1 : Come back the gateway web UI to get the gateway Public key**(%%) ==== 461 461 462 462 ... ... @@ -520,5 +520,3 @@ 520 520 ))) 521 521 522 522 [[image:image-20220531153219-17.png]] 523 - 524 -
- image-20230320105212-1.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Kilight - Size
-
... ... @@ -1,1 +1,0 @@ 1 -109.6 KB - Content
- image-20230320105842-2.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Kilight - Size
-
... ... @@ -1,1 +1,0 @@ 1 -85.6 KB - Content
- image-20230320105938-3.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Kilight - Size
-
... ... @@ -1,1 +1,0 @@ 1 -82.6 KB - Content
- image-20230320110123-4.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Kilight - Size
-
... ... @@ -1,1 +1,0 @@ 1 -80.1 KB - Content
- image-20230320110309-5.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Kilight - Size
-
... ... @@ -1,1 +1,0 @@ 1 -60.4 KB - Content
- image-20230320112057-6.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Kilight - Size
-
... ... @@ -1,1 +1,0 @@ 1 -47.8 KB - Content