Changes for page Monitor & Remote Access Gateway
Last modified by Kilight Cao on 2025/01/14 10:25
Change comment:
There is no comment for this version
Summary
-
Page properties (2 modified, 0 added, 0 removed)
Details
- Page properties
-
- Author
-
... ... @@ -1,1 +1,1 @@ 1 -XWiki. Kilight1 +XWiki.Edwin - Content
-
... ... @@ -5,9 +5,9 @@ 5 5 6 6 7 7 8 -= **1. Monitor Gateway**=8 += 1. Monitor Gateway = 9 9 10 -== **1.1 Introduction**==10 +== 1.1 Introduction == 11 11 12 12 13 13 This introduction shows how to use a script to monitor the gateway. The video link for this instruction is: [[https:~~/~~/youtu.be/8PieIwfSF_g>>url:https://youtu.be/8PieIwfSF_g]] ... ... @@ -16,10 +16,9 @@ 16 16 [[image:image-20220531155018-18.png]] 17 17 18 18 19 +== 1.2 Steps == 19 19 20 -== **1.2 Steps** == 21 21 22 - 23 23 * Create account in ThingsSpeak and creat channel. 24 24 * Download script from dragino site and move it to properly directory 25 25 ... ... @@ -73,7 +73,7 @@ 73 73 * Reboot device. 74 74 75 75 76 -== **1.3 Monitor Public IP**==75 +== 1.3 Monitor Public IP == 77 77 78 78 79 79 The monitor_gateway.sh has been updated to upload the public ip of the device as well. ... ... @@ -86,12 +86,11 @@ 86 86 Find Public IP 87 87 88 88 88 += 2. Remote Access = 89 89 90 -= **2. Remote Access**=90 +== 2.1 Remote Access via Remote.it. == 91 91 92 -= **2.1 Remote Access via Remote.it.** = 93 93 94 - 95 95 Remote.it for remote access is available in the latest Dragino firmware for gateway. For security concern, the remote.it only available base on end user demand. 96 96 97 97 ... ... @@ -120,7 +120,7 @@ 120 120 121 121 (% class="box infomessage" %) 122 122 ((( 123 -** 57F60715-606F-510D-A3D2-739860EBDB98**121 +**fd173d1d-faed-493e-a868-c511a38aba45** 124 124 ))) 125 125 126 126 [[image:image-20220725113010-1.png||height="455" width="899"]] ... ... @@ -135,10 +135,9 @@ 135 135 [[image:image-20220725115720-2.png||height="658" width="900"]] 136 136 137 137 136 +=== 2.1.1 How to save the registered remote after the gateway's firmware update. === 138 138 139 -== **2.1.1 How to save the registered remote after the gateway's firmware update.** == 140 140 141 - 142 142 Before version [[lgw~~-~~-build-v5.4.1668240318-20221112-1606>>http://repo.dragino.com/release/miscellaneous/remoteit/dragino-lgw--v5.4.1668240318-squashfs-sysupgrade.bin]], once the gateway firmware is upgraded the remote configuration is gone. 143 143 144 144 This issue is now corrected: ... ... @@ -145,7 +145,7 @@ 145 145 146 146 147 147 148 -=== **The gateway version is lower than** **lgw~-~-build-v5.4.1668240318-20221112-1606:** === 145 +==== **The gateway version is lower than** **lgw~-~-build-v5.4.1668240318-20221112-1606:** ==== 149 149 150 150 151 151 **~1. upload the [[backup file>>http://repo.dragino.com/release/miscellaneous/remoteit/backup.tar.gz]] to update the configuration.** ... ... @@ -160,7 +160,7 @@ 160 160 161 161 162 162 163 -=== **The gateway version is greater or equal to** **lgw~-~-build-v5.4.1668240318-20221112-1606:** === 160 +==== **The gateway version is greater or equal to** **lgw~-~-build-v5.4.1668240318-20221112-1606:** ==== 164 164 165 165 166 166 ... ... @@ -169,10 +169,9 @@ 169 169 [[image:image-20221112162547-3.png]] 170 170 171 171 169 +=== 2.1.2 How to register hp0d with Remote.it === 172 172 173 -== **2.1.2 How to register hp0d with Remote.it** == 174 174 175 - 176 176 **Prerequisites:** 177 177 178 178 Users must have an account and APP for remote.it ... ... @@ -180,7 +180,7 @@ 180 180 **[[https:~~/~~/app.remote.it>>https://app.remote.it]]** 181 181 182 182 183 -=== (% style="color:blue" %)**1. Click "+" in the APP to add a device**(%%) === 179 +==== (% style="color:blue" %)**1. Click "+" in the APP to add a device**(%%) ==== 184 184 185 185 186 186 Then click Add "Linux & Raspberry Pi" and the APP will generate a command to register the device. ... ... @@ -190,7 +190,7 @@ 190 190 191 191 192 192 193 -=== (% style="color:blue" %)**2. Copy the register device command**(%%) === 189 +==== (% style="color:blue" %)**2. Copy the register device command**(%%) ==== 194 194 195 195 196 196 [[image:image-20220815173944-2.jpeg||height="556" width="923"]] ... ... @@ -197,7 +197,7 @@ 197 197 198 198 199 199 200 -=== (% style="color:blue" %)**3. Enter the command copied from the previous step on the HP0D Linux command line**(%%) === 196 +==== (% style="color:blue" %)**3. Enter the command copied from the previous step on the HP0D Linux command line**(%%) ==== 201 201 202 202 203 203 [[image:image-20220815173951-3.jpeg||height="424" width="1147"]] ... ... @@ -204,13 +204,13 @@ 204 204 205 205 206 206 207 -=== (% style="color:blue" %)**4. Check whether the device is successfully registered on the Remote.it APP**(%%) === 203 +==== (% style="color:blue" %)**4. Check whether the device is successfully registered on the Remote.it APP**(%%) ==== 208 208 209 209 210 210 [[image:image-20220815173958-4.jpeg||height="580" width="964"]] 211 211 212 212 213 -== **2.1.3 How to register the gateway with Remote.it via SSH Access for Linux console**==209 +=== 2.1.3 How to register the gateway with Remote.it via SSH Access for Linux console === 214 214 215 215 216 216 **Prerequisites:** ... ... @@ -222,7 +222,7 @@ 222 222 For detailed examples, please see: **[[OpenWrt How to Connect Guide (remote.it)>>url:https://www.remote.it/getting-started/openwrt]]** 223 223 224 224 225 -=== (% style="color:blue" %)**1. Click "+" in the APP to add a device**(%%) === 221 +==== (% style="color:blue" %)**1. Click "+" in the APP to add a device**(%%) ==== 226 226 227 227 228 228 Then click Add "OpenWrt" and the APP will generate a command to register the device. ... ... @@ -230,27 +230,32 @@ 230 230 [[image:image-20230320110123-4.png||height="657" width="1191"]] 231 231 232 232 233 -=== (% style="color:blue" %)**2. Copy the register device command**(%%) === 234 234 230 +==== (% style="color:blue" %)**2. Copy the register device command**(%%) ==== 235 235 232 + 236 236 [[image:image-20230320110309-5.png||height="635" width="1197"]] 237 237 238 238 239 -=== (% style="color:blue" %)**3. Enter the command copied from the previous step on the gateway Linux command line**(%%) === 240 240 241 -=== [[image:image-20230320105212-1.png||height="758"width="820"]]===237 +==== (% style="color:blue" %)**3. Enter the command copied from the previous step on the gateway Linux command line**(%%) ==== 242 242 243 243 244 -=== (% style="color:blue" %)**4. Check whether the device is successfully registered on the Remote.it APP**(%%) === 240 +(% class="wikigeneratedid" id="H" %) 241 +[[image:image-20230320105212-1.png||height="758" width="820"]] 245 245 246 246 244 + 245 +==== (% style="color:blue" %)**4. Check whether the device is successfully registered on the Remote.it APP**(%%) ==== 246 + 247 + 247 247 [[image:image-20230320112057-6.png||height="603" width="1135"]] 248 248 249 249 250 -== **2.1.4 Trouble Shooting**==251 +=== 2.1.4 Trouble Shooting === 251 251 252 252 253 -=== **1. What should users do when gateway Remote.it installation fails** === 254 +==== **1. What should users do when gateway Remote.it installation fails** ==== 254 254 255 255 256 256 [[image:image-20220907162028-4.png||height="564" width="1148"]] ... ... @@ -270,10 +270,9 @@ 270 270 (% style="color:blue" %)**Step 3:**(%%) Follow the [[Remoteit user instruction for Dragino Gateway>>https://www.remote.it/getting-started/dragino]] steps to reconfigure 271 271 272 272 274 +== 2.2 RSSH Introduction == 273 273 274 -= **2.2 RSSH Introduction** = 275 275 276 - 277 277 Reverse SSH for remote access is available in the latest Dragino firmware for gateway. For security concern, the RSSH only available base on end user demand. 278 278 279 279 (% style="color:red" %)**Important Notice:** ... ... @@ -281,7 +281,9 @@ 281 281 (% class="box warningmessage" %) 282 282 ((( 283 283 RSSH access will give full control of your device to remote support. Please remove sensitivity info before perform this 284 -This RSSH allow Dragino Support to remote access to the device, If user want to access himself, he need to set up the RSSH server himself. 284 +This RSSH allow Dragino Support Team to remote access to customer's device. Customer is not able to remote access it via Dragino Server. 285 + 286 +If user want to access himself, he need to set up the RSSH server himself. 285 285 ))) 286 286 287 287 ... ... @@ -295,9 +295,10 @@ 295 295 * LIG16 296 296 * MS14 series if installed with the same firmware. 297 297 298 -=== **2.2.1 End User Guide to use SSH access** === 299 299 301 +=== 2.2.1 End User Guide to use SSH access === 300 300 303 + 301 301 Go to this the Reverse SSH page as below: 302 302 303 303 ... ... @@ -321,10 +321,9 @@ 321 321 After doing above, please download and mail the public keys to Dragino support and wait for our mail for the valid host port. Input the valid host port got from our support and click connect so we can remote access to your gateway. 322 322 323 323 327 +=== 2.2.2 Set Up RSSH Server === 324 324 325 -=== **2.2.2 Set Up RSSH Server** === 326 326 327 - 328 328 Advance administrator can config a SSH server to provide support their end user themselves., Steps as below 329 329 330 330 ... ... @@ -456,11 +456,10 @@ 456 456 {{{ check: sudo ls /home/xxxxx/.ssh/authorizedkey}}} 457 457 458 458 461 +=== 2.2.3 How does user get the gateway to connect to a user's private server === 459 459 460 -=== **2.2.3 How does user get the gateway to connect to a user's private server** === 461 461 462 462 463 - 464 464 ==== (% style="color:blue" %)**Step 1 : Come back the gateway web UI to get the gateway Public key**(%%) ==== 465 465 466 466