From version < 71.1 >
edited by Kilight Cao
on 2023/03/20 11:21
To version < 72.4 >
edited by Xiaoling
on 2023/04/11 16:10
>
Change comment: There is no comment for this version

Summary

Details

Page properties
Author
... ... @@ -1,1 +1,1 @@
1 -XWiki.Kilight
1 +XWiki.Xiaoling
Content
... ... @@ -5,9 +5,9 @@
5 5  
6 6  
7 7  
8 -= **1.  Monitor Gateway** =
8 += 1.  Monitor Gateway =
9 9  
10 -== **1.1  Introduction** ==
10 +== 1.1  Introduction ==
11 11  
12 12  
13 13  This introduction shows how to use a script to monitor the gateway. The video link for this instruction is: [[https:~~/~~/youtu.be/8PieIwfSF_g>>url:https://youtu.be/8PieIwfSF_g]]
... ... @@ -16,10 +16,9 @@
16 16  [[image:image-20220531155018-18.png]]
17 17  
18 18  
19 +== 1.2  Steps ==
19 19  
20 -== **1.2  Steps** ==
21 21  
22 -
23 23  * Create account in ThingsSpeak and creat channel.
24 24  * Download script from dragino site and move it to properly directory
25 25  
... ... @@ -73,9 +73,10 @@
73 73  * Reboot device.
74 74  
75 75  
76 -== **1.3  Monitor Public IP** ==
77 77  
76 +== 1.3  Monitor Public IP ==
78 78  
78 +
79 79  The monitor_gateway.sh has been updated to upload the public ip of the device as well.
80 80  
81 81  User can find the public ip in field7, the chart is not able to show the complete public ip, user can check that in the export.
... ... @@ -86,12 +86,11 @@
86 86  Find Public IP
87 87  
88 88  
89 += 2.  Remote Access =
89 89  
90 -= **2.  Remote Access** =
91 +== 2.1  Remote Access via Remote.it. ==
91 91  
92 -= **2.1  Remote Access via Remote.it.** =
93 93  
94 -
95 95  Remote.it for remote access is available in the latest Dragino firmware for gateway. For security concern, the remote.it only available base on end user demand.
96 96  
97 97  
... ... @@ -120,7 +120,7 @@
120 120  
121 121  (% class="box infomessage" %)
122 122  (((
123 -**57F60715-606F-510D-A3D2-739860EBDB98**
122 +**fd173d1d-faed-493e-a868-c511a38aba45**
124 124  )))
125 125  
126 126  [[image:image-20220725113010-1.png||height="455" width="899"]]
... ... @@ -135,10 +135,9 @@
135 135  [[image:image-20220725115720-2.png||height="658" width="900"]]
136 136  
137 137  
137 +=== 2.1.1  How to save the registered remote after the gateway's firmware update. ===
138 138  
139 -== **2.1.1  How to save the registered remote after the gateway's firmware update.** ==
140 140  
141 -
142 142  Before version [[lgw~~-~~-build-v5.4.1668240318-20221112-1606>>http://repo.dragino.com/release/miscellaneous/remoteit/dragino-lgw--v5.4.1668240318-squashfs-sysupgrade.bin]], once the gateway firmware is upgraded the remote configuration is gone.
143 143  
144 144  This issue is now corrected:
... ... @@ -145,7 +145,7 @@
145 145  
146 146  
147 147  
148 -=== **The gateway version is lower than** **lgw~-~-build-v5.4.1668240318-20221112-1606:** ===
146 +==== **The gateway version is lower than** **lgw~-~-build-v5.4.1668240318-20221112-1606:** ====
149 149  
150 150  
151 151  **~1. upload the [[backup file>>http://repo.dragino.com/release/miscellaneous/remoteit/backup.tar.gz]] to update the configuration.**
... ... @@ -160,7 +160,7 @@
160 160  
161 161  
162 162  
163 -=== **The gateway version is greater or equal to**  **lgw~-~-build-v5.4.1668240318-20221112-1606:** ===
161 +==== **The gateway version is greater or equal to**  **lgw~-~-build-v5.4.1668240318-20221112-1606:** ====
164 164  
165 165  
166 166  
... ... @@ -169,10 +169,9 @@
169 169  [[image:image-20221112162547-3.png]]
170 170  
171 171  
170 +=== 2.1.2  How to register hp0d with Remote.it ===
172 172  
173 -== **2.1.2  How to register hp0d with Remote.it** ==
174 174  
175 -
176 176  **Prerequisites:**
177 177  
178 178  Users must have an account and APP for remote.it
... ... @@ -180,7 +180,7 @@
180 180  **[[https:~~/~~/app.remote.it>>https://app.remote.it]]**
181 181  
182 182  
183 -=== (% style="color:blue" %)**1.  Click "+" in the APP to add a device**(%%) ===
180 +==== (% style="color:blue" %)**1.  Click "+" in the APP to add a device**(%%) ====
184 184  
185 185  
186 186  Then click Add "Linux & Raspberry Pi" and the APP will generate a command to register the device.
... ... @@ -190,7 +190,7 @@
190 190  
191 191  
192 192  
193 -=== (% style="color:blue" %)**2.  Copy the register device command**(%%) ===
190 +==== (% style="color:blue" %)**2.  Copy the register device command**(%%) ====
194 194  
195 195  
196 196  [[image:image-20220815173944-2.jpeg||height="556" width="923"]]
... ... @@ -197,7 +197,7 @@
197 197  
198 198  
199 199  
200 -=== (% style="color:blue" %)**3.  Enter the command copied from the previous step on the HP0D Linux command line**(%%) ===
197 +==== (% style="color:blue" %)**3.  Enter the command copied from the previous step on the HP0D Linux command line**(%%) ====
201 201  
202 202  
203 203  [[image:image-20220815173951-3.jpeg||height="424" width="1147"]]
... ... @@ -204,13 +204,13 @@
204 204  
205 205  
206 206  
207 -=== (% style="color:blue" %)**4.  Check whether the device is successfully registered on the Remote.it APP**(%%) ===
204 +==== (% style="color:blue" %)**4.  Check whether the device is successfully registered on the Remote.it APP**(%%) ====
208 208  
209 209  
210 210  [[image:image-20220815173958-4.jpeg||height="580" width="964"]]
211 211  
212 212  
213 -== **2.1.3  How to register the gateway with Remote.it via SSH Access for Linux console** ==
210 +=== 2.1.3  How to register the gateway with Remote.it via SSH Access for Linux console ===
214 214  
215 215  
216 216  **Prerequisites:**
... ... @@ -222,7 +222,7 @@
222 222  For detailed examples, please see: **[[OpenWrt How to Connect Guide (remote.it)>>url:https://www.remote.it/getting-started/openwrt]]**
223 223  
224 224  
225 -=== (% style="color:blue" %)**1.  Click "+" in the APP to add a device**(%%) ===
222 +==== (% style="color:blue" %)**1.  Click "+" in the APP to add a device**(%%) ====
226 226  
227 227  
228 228  Then click Add "OpenWrt" and the APP will generate a command to register the device.
... ... @@ -230,27 +230,32 @@
230 230  [[image:image-20230320110123-4.png||height="657" width="1191"]]
231 231  
232 232  
233 -=== (% style="color:blue" %)**2.  Copy the register device command**(%%) ===
234 234  
231 +==== (% style="color:blue" %)**2.  Copy the register device command**(%%) ====
235 235  
233 +
236 236  [[image:image-20230320110309-5.png||height="635" width="1197"]]
237 237  
238 238  
239 -=== (% style="color:blue" %)**3.  Enter the command copied from the previous step on the gateway Linux command line**(%%) ===
240 240  
241 -=== [[image:image-20230320105212-1.png||height="758" width="820"]] ===
238 +==== (% style="color:blue" %)**3.  Enter the command copied from the previous step on the gateway Linux command line**(%%) ====
242 242  
243 243  
244 -=== (% style="color:blue" %)**4.  Check whether the device is successfully registered on the Remote.it APP**(%%) ===
241 +(% class="wikigeneratedid" id="H" %)
242 +[[image:image-20230320105212-1.png||height="758" width="820"]]
245 245  
246 246  
245 +
246 +==== (% style="color:blue" %)**4.  Check whether the device is successfully registered on the Remote.it APP**(%%) ====
247 +
248 +
247 247  [[image:image-20230320112057-6.png||height="603" width="1135"]]
248 248  
249 249  
250 -== **2.1.4  Trouble Shooting** ==
252 +=== 2.1.4  Trouble Shooting ===
251 251  
252 252  
253 -=== **1. What should users do when gateway Remote.it installation fails** ===
255 +==== **1. What should users do when gateway Remote.it installation fails** ====
254 254  
255 255  
256 256  [[image:image-20220907162028-4.png||height="564" width="1148"]]
... ... @@ -270,10 +270,9 @@
270 270  (% style="color:blue" %)**Step 3:**(%%) Follow the [[Remoteit user instruction for Dragino Gateway>>https://www.remote.it/getting-started/dragino]] steps to reconfigure
271 271  
272 272  
275 +== 2.2  RSSH Introduction ==
273 273  
274 -= **2.2  RSSH Introduction** =
275 275  
276 -
277 277  Reverse SSH for remote access is available in the latest Dragino firmware for gateway. For security concern, the RSSH only available base on end user demand.
278 278  
279 279  (% style="color:red" %)**Important Notice:**
... ... @@ -295,9 +295,11 @@
295 295  * LIG16
296 296  * MS14 series if installed with the same firmware.
297 297  
298 -=== **2.2.1  End User Guide to use SSH access** ===
299 299  
300 300  
301 +=== 2.2.1  End User Guide to use SSH access ===
302 +
303 +
301 301  Go to this the Reverse SSH page as below:
302 302  
303 303  
... ... @@ -321,10 +321,9 @@
321 321  After doing above, please download and mail the public keys to Dragino support and wait for our mail for the valid host port. Input the valid host port got from our support and click connect so we can remote access to your gateway.
322 322  
323 323  
327 +=== 2.2.2  Set Up RSSH Server ===
324 324  
325 -=== **2.2.2  Set Up RSSH Server** ===
326 326  
327 -
328 328  Advance administrator can config a SSH server to provide support their end user themselves., Steps as below
329 329  
330 330  
... ... @@ -456,11 +456,10 @@
456 456  {{{ check: sudo ls /home/xxxxx/.ssh/authorizedkey}}}
457 457  
458 458  
461 +=== 2.2.3  How does user get the gateway to connect to a user's private server ===
459 459  
460 -=== **2.2.3  How does user get the gateway to connect to a user's private server** ===
461 461  
462 462  
463 -
464 464  ==== (% style="color:blue" %)**Step 1 :  Come back the gateway web UI to get the gateway Public key**(%%) ====
465 465  
466 466  
... ... @@ -524,3 +524,4 @@
524 524  )))
525 525  
526 526  [[image:image-20220531153219-17.png]]
528 +
Copyright ©2010-2022 Dragino Technology Co., LTD. All rights reserved