Changes for page Monitor & Remote Access Gateway
Last modified by Kilight Cao on 2025/01/14 10:25
Change comment:
There is no comment for this version
Summary
-
Page properties (2 modified, 0 added, 0 removed)
-
Attachments (0 modified, 0 added, 9 removed)
Details
- Page properties
-
- Author
-
... ... @@ -1,1 +1,1 @@ 1 -XWiki. Xiaoling1 +XWiki.Kilight - Content
-
... ... @@ -12,7 +12,6 @@ 12 12 13 13 This introduction shows how to use a script to monitor the gateway. The video link for this instruction is: [[https:~~/~~/youtu.be/8PieIwfSF_g>>url:https://youtu.be/8PieIwfSF_g]] 14 14 15 - 16 16 [[image:image-20220531155018-18.png]] 17 17 18 18 ... ... @@ -37,7 +37,6 @@ 37 37 ))) 38 38 39 39 40 - 41 41 * change the script monitor_gateway.sh with properly users setting: 42 42 43 43 (% class="box infomessage" %) ... ... @@ -49,7 +49,6 @@ 49 49 ))) 50 50 51 51 52 - 53 53 * run (% style="color:blue" %)**/usr/bin/monitor_gateway.sh**(%%) to test if upload is good. 54 54 55 55 * Add monitor_gateway.sh to cron work (% style="color:blue" %)**/etc/crontabs/root**(%%) to make this script runs perdiocally, below is an example to update every 20 minutes ... ... @@ -90,7 +90,7 @@ 90 90 91 91 = **2. Remote Access** = 92 92 93 -= **2.1 Remote Access via Remote.it.** = 90 +== **2.1 Remote Access via Remote.it.** == 94 94 95 95 96 96 Remote.it for remote access is available in the latest Dragino firmware for gateway. For security concern, the remote.it only available base on end user demand. ... ... @@ -101,9 +101,10 @@ 101 101 * Remote.it access will give full control of your device to remote support. 102 102 * The Remote.it allows Dragino Support to remote access to the device, If user want to access himself, it need to sign up for an remote.it account. 103 103 104 -* For how to use remote.it for (% style="color:blue" %)**general remote control**(%%), please see : [[Remoteit user instruction for Dragino Gateway>>https://www.r emote.it/getting-started/dragino]].101 +* For how to use remote.it for (% style="color:blue" %)**general remote control**(%%), please see : [[Remoteit user instruction for Dragino Gateway>>url:https://www.dragino.com/downloads/index.php?dir=LoRa_Gateway/&file=Dragino-Remoteit_User_Manual.pdf]]. 105 105 * For Quick add remote.it to (% style="color:blue" %)**Dragino for remote debug**(%%), please see below: 106 106 104 + 107 107 (% style="color:blue" %)**1. Install the Remote.it software** 108 108 109 109 Users can directly click** "Install"** on the Web UI to install Remote. it. ... ... @@ -137,43 +137,9 @@ 137 137 [[image:image-20220725115720-2.png||height="658" width="900"]] 138 138 139 139 138 +=== **How to register hp0d with AWS** === 140 140 141 -== **2.1.1 How to save the registered remote after the gateway's firmware update.** == 142 142 143 -Before version [[lgw~~-~~-build-v5.4.1668240318-20221112-1606>>http://repo.dragino.com/release/miscellaneous/remoteit/dragino-lgw--v5.4.1668240318-squashfs-sysupgrade.bin]], once the gateway firmware is upgraded the remote configuration is gone. 144 - 145 -This issue is now corrected: 146 - 147 - 148 - 149 -=== **The gateway version is lower than** **lgw~-~-build-v5.4.1668240318-20221112-1606:** === 150 - 151 - 152 -**~1. upload the [[backup file>>http://repo.dragino.com/release/miscellaneous/remoteit/backup.tar.gz]] to update the configuration.** 153 - 154 -[[image:image-20221112162644-4.png]] 155 - 156 - 157 - 158 -**2. Check the 'Preserver Settings' check box when you upgrade the gateway with the firmware. ** 159 - 160 -[[image:image-20221112162543-2.png]] 161 - 162 - 163 - 164 -=== **The gateway version is greater or equal to** **lgw~-~-build-v5.4.1668240318-20221112-1606:** === 165 - 166 - 167 - 168 -**~1. Only to do: Check the 'Preserver Settings' check box when you upgrade the gateway with the firmware. ** 169 - 170 -[[image:image-20221112162547-3.png]] 171 - 172 - 173 - 174 -== **2.1.2 How to register hp0d with Remote.it** == 175 - 176 - 177 177 **Prerequisites:** 178 178 179 179 Users must have an account and APP for remote.it ... ... @@ -181,9 +181,8 @@ 181 181 [[https:~~/~~/app.remote.it>>https://app.remote.it]] 182 182 183 183 184 - ===(% style="color:blue" %)**1.(%%) ===148 +(% style="color:blue" %)**1. Click "+" in the APP to add a device** 185 185 186 - 187 187 Then click Add "Linux & Raspberry Pi" and the APP will generate a command to register the device. 188 188 189 189 ... ... @@ -190,55 +190,26 @@ 190 190 [[image:image-20220815173938-1.jpeg||height="574" width="919"]] 191 191 192 192 156 +(% style="color:blue" %)**2.Copy the register device command** 193 193 194 -=== (% style="color:blue" %)**2. Copy the register device command**(%%) === 195 195 196 - 197 197 [[image:image-20220815173944-2.jpeg||height="556" width="923"]] 198 198 199 199 162 +(% style="color:blue" %)**3.Enter the command copied from the previous step on the HP0D Linux command line** 200 200 201 -=== (% style="color:blue" %)**3. Enter the command copied from the previous step on the HP0D Linux command line**(%%) === 202 - 203 - 204 204 [[image:image-20220815173951-3.jpeg||height="424" width="1147"]] 205 205 206 206 167 +(% style="color:blue" %)**4.Check whether the device is successfully registered on the Remote.it APP** 207 207 208 -=== (% style="color:blue" %)**4. Check whether the device is successfully registered on the Remote.it APP**(%%) === 209 209 210 - 211 211 [[image:image-20220815173958-4.jpeg||height="580" width="964"]] 212 212 213 213 173 +== **2.2 RSSH Introduction** == 214 214 215 -== **2.1.3 Trouble Shooting** == 216 216 217 - 218 -=== **1. What should users do when gateway Remote.it installation fails** === 219 - 220 - 221 -[[image:image-20220907162028-4.png||height="564" width="1148"]] 222 - 223 - 224 -(% style="color:blue" %)**Step 1: **(%%)Users can download the archive and upload it to the gateway:** [[attach:backup.tar.gz||target="_blank"]]** 225 - 226 -[[image:image-20220907161050-2.png]] 227 - 228 - 229 - 230 -(% style="color:blue" %)**Step 2: **(%%)Back to the Remote.it screen, and click **"Install"** again. 231 - 232 -[[image:image-20220907161352-3.png]] 233 - 234 - 235 -(% style="color:blue" %)**Step 3:**(%%) Follow the [[Remoteit user instruction for Dragino Gateway>>https://www.remote.it/getting-started/dragino]] steps to reconfigure 236 - 237 - 238 - 239 -= **2.2 RSSH Introduction** = 240 - 241 - 242 242 Reverse SSH for remote access is available in the latest Dragino firmware for gateway. For security concern, the RSSH only available base on end user demand. 243 243 244 244 (% style="color:red" %)**Important Notice:** ... ... @@ -262,6 +262,7 @@ 262 262 263 263 264 264 199 + 265 265 === **2.2.1 End User Guide to use SSH access** === 266 266 267 267 ... ... @@ -491,3 +491,5 @@ 491 491 ))) 492 492 493 493 [[image:image-20220531153219-17.png]] 429 + 430 +
- backup.tar.gz
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Kilight - Size
-
... ... @@ -1,1 +1,0 @@ 1 -93.3 KB - Content
- image-20220907160848-1.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Kilight - Size
-
... ... @@ -1,1 +1,0 @@ 1 -39.7 KB - Content
- image-20220907161050-2.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Kilight - Size
-
... ... @@ -1,1 +1,0 @@ 1 -57.6 KB - Content
- image-20220907161352-3.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Kilight - Size
-
... ... @@ -1,1 +1,0 @@ 1 -39.2 KB - Content
- image-20220907162028-4.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Kilight - Size
-
... ... @@ -1,1 +1,0 @@ 1 -42.6 KB - Content
- image-20221112162416-1.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Xiaoye - Size
-
... ... @@ -1,1 +1,0 @@ 1 -53.7 KB - Content
- image-20221112162543-2.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Xiaoye - Size
-
... ... @@ -1,1 +1,0 @@ 1 -63.2 KB - Content
- image-20221112162547-3.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Xiaoye - Size
-
... ... @@ -1,1 +1,0 @@ 1 -63.2 KB - Content
- image-20221112162644-4.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Xiaoye - Size
-
... ... @@ -1,1 +1,0 @@ 1 -55.7 KB - Content