... ... @@ -23,8 +23,6 @@
23 23  * Create account in ThingsSpeak and creat channel.
24 24  * Download script from dragino site and move it to properly directory
25 25  
26 -
27 -
28 28  (% class="box infomessage" %)
29 29  (((
30 30  root@dragino-1baf44:~~# wget [[http:~~/~~/www.dragino.com/downloads/downloads/LoRa_Gateway/LPS8/Firmware/customized_script/monitor_gateway.sh>>url:http://www.dragino.com/downloads/downloads/LoRa_Gateway/LPS8/Firmware/customized_script/monitor_gateway.sh]]
... ... @@ -42,8 +42,6 @@
42 42  
43 43  * change the script monitor_gateway.sh with properly users setting:
44 44  
45 -
46 -
47 47  (% class="box infomessage" %)
48 48  (((
49 49  USER='xxxxx'             # user name in your thinkspeak ~-~-> Profile
... ... @@ -58,8 +58,6 @@
58 58  
59 59  * Add monitor_gateway.sh to cron work (% style="color:blue" %)**/etc/crontabs/root**(%%) to make this script runs perdiocally, below is an example to update every 20 minutes
60 60  
61 -
62 -
63 63  (% class="box infomessage" %)
64 64  (((
65 65  # For details see man 4 crontabs
... ... @@ -80,8 +80,6 @@
80 80  
81 81  
82 82  
83 -
84 -
85 85  == **1.3  Monitor Public IP** ==
86 86  
87 87  
... ... @@ -98,7 +98,7 @@
98 98  
99 99  = **2.  Remote Access** =
100 100  
101 -== **2.1  Remote Access via Remote.it.** ==
93 += **2.1  Remote Access via Remote.it.** =
102 102  
103 103  
104 104  Remote.it for remote access is available in the latest Dragino firmware for gateway. For security concern, the remote.it only available base on end user demand.
... ... @@ -112,9 +112,6 @@
112 112  * For how to use remote.it for (% style="color:blue" %)**general remote control**(%%), please see :  [[Remoteit user instruction for Dragino Gateway>>https://www.remote.it/getting-started/dragino]].
113 113  * For Quick add remote.it to (% style="color:blue" %)**Dragino for remote debug**(%%), please see below:
114 114  
115 -
116 -
117 -
118 118  (% style="color:blue" %)**1. Install the Remote.it software**
119 119  
120 120  Users can directly click** "Install"** on the Web UI to install Remote. it.
... ... @@ -148,9 +148,44 @@
148 148  [[image:image-20220725115720-2.png||height="658" width="900"]]
149 149  
150 150  
151 -=== **2.1.1  How to register hp0d with Remote.it** ===
152 152  
141 +== **2.1.1  How to save the registered remote after the gateway's firmware update.** ==
153 153  
143 +
144 +Before version [[lgw~~-~~-build-v5.4.1668240318-20221112-1606>>http://repo.dragino.com/release/miscellaneous/remoteit/dragino-lgw--v5.4.1668240318-squashfs-sysupgrade.bin]], once the gateway firmware is upgraded the remote configuration is gone.
145 +
146 +This issue is now corrected:
147 +
148 +
149 +
150 +=== **The gateway version is lower than** **lgw~-~-build-v5.4.1668240318-20221112-1606:** ===
151 +
152 +
153 +**~1. upload the [[backup file>>http://repo.dragino.com/release/miscellaneous/remoteit/backup.tar.gz]] to update the configuration.**
154 +
155 +[[image:image-20221112162644-4.png]]
156 +
157 +
158 +
159 +**2. Check the 'Preserver Settings' check box when you upgrade the gateway with the firmware. **
160 +
161 +[[image:image-20221112162543-2.png]]
162 +
163 +
164 +
165 +=== **The gateway version is greater or equal to**  **lgw~-~-build-v5.4.1668240318-20221112-1606:** ===
166 +
167 +
168 +
169 +**~1. Only to do: Check the 'Preserver Settings' check box when you upgrade the gateway with the firmware. **
170 +
171 +[[image:image-20221112162547-3.png]]
172 +
173 +
174 +
175 +== **2.1.2  How to register hp0d with Remote.it** ==
176 +
177 +
154 154  **Prerequisites:**
155 155  
156 156  Users must have an account and APP for remote.it
... ... @@ -158,8 +158,9 @@
158 158  [[https:~~/~~/app.remote.it>>https://app.remote.it]]
159 159  
160 160  
161 -(% style="color:blue" %)**1. Click "+" in the APP to add a device**
185 +=== (% style="color:blue" %)**1.  Click "+" in the APP to add a device**(%%) ===
162 162  
187 +
163 163  Then click Add "Linux & Raspberry Pi" and the APP will generate a command to register the device.
164 164  
165 165  
... ... @@ -167,7 +167,7 @@
167 167  
168 168  
169 169  
170 -(% style="color:blue" %)**2.Copy the register device command**
195 +=== (% style="color:blue" %)**2.  Copy the register device command**(%%) ===
171 171  
172 172  
173 173  [[image:image-20220815173944-2.jpeg||height="556" width="923"]]
... ... @@ -174,7 +174,7 @@
174 174  
175 175  
176 176  
177 -(% style="color:blue" %)**3.Enter the command copied from the previous step on the HP0D Linux command line**
202 +=== (% style="color:blue" %)**3.  Enter the command copied from the previous step on the HP0D Linux command line**(%%) ===
178 178  
179 179  
180 180  [[image:image-20220815173951-3.jpeg||height="424" width="1147"]]
... ... @@ -181,15 +181,40 @@
181 181  
182 182  
183 183  
184 -(% style="color:blue" %)**4.Check whether the device is successfully registered on the Remote.it APP**
209 +=== (% style="color:blue" %)**4.  Check whether the device is successfully registered on the Remote.it APP**(%%) ===
185 185  
186 186  
187 187  [[image:image-20220815173958-4.jpeg||height="580" width="964"]]
188 188  
189 189  
190 -== **2.2  RSSH Introduction** ==
191 191  
216 +== **2.1.3  Trouble Shooting** ==
192 192  
218 +
219 +=== **1. What should users do when gateway Remote.it installation fails** ===
220 +
221 +
222 +[[image:image-20220907162028-4.png||height="564" width="1148"]]
223 +
224 +
225 +(% style="color:blue" %)**Step 1:  **(%%)Users can download the archive and upload it to the gateway:** [[attach:backup.tar.gz||target="_blank"]]**
226 +
227 +[[image:image-20220907161050-2.png]]
228 +
229 +
230 +
231 +(% style="color:blue" %)**Step 2:  **(%%)Back to the Remote.it screen, and click **"Install"** again.
232 +
233 +[[image:image-20220907161352-3.png]]
234 +
235 +
236 +(% style="color:blue" %)**Step 3:**(%%) Follow the [[Remoteit user instruction for Dragino Gateway>>https://www.remote.it/getting-started/dragino]] steps to reconfigure
237 +
238 +
239 +
240 += **2.2  RSSH Introduction** =
241 +
242 +
193 193  Reverse SSH for remote access is available in the latest Dragino firmware for gateway. For security concern, the RSSH only available base on end user demand.
194 194  
195 195  (% style="color:red" %)**Important Notice:**
... ... @@ -212,9 +212,6 @@
212 212  * MS14 series if installed with the same firmware.
213 213  
214 214  
215 -
216 -
217 -
218 218  === **2.2.1  End User Guide to use SSH access** ===
219 219  
220 220  
... ... @@ -444,5 +444,3 @@
444 444  )))
445 445  
446 446  [[image:image-20220531153219-17.png]]
447 -
448 -
image-20221112162416-1.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Xiaoye
Size
... ... @@ -1,0 +1,1 @@
1 +53.7 KB
Content
image-20221112162543-2.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Xiaoye
Size
... ... @@ -1,0 +1,1 @@
1 +63.2 KB
Content
image-20221112162547-3.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Xiaoye
Size
... ... @@ -1,0 +1,1 @@
1 +63.2 KB
Content
image-20221112162644-4.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Xiaoye
Size
... ... @@ -1,0 +1,1 @@
1 +55.7 KB
Content
image-20230320105212-1.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Kilight
Size
... ... @@ -1,0 +1,1 @@
1 +109.6 KB
Content
image-20230320105842-2.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Kilight
Size
... ... @@ -1,0 +1,1 @@
1 +85.6 KB
Content
image-20230320105938-3.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Kilight
Size
... ... @@ -1,0 +1,1 @@
1 +82.6 KB
Content
Copyright ©2010-2022 Dragino Technology Co., LTD. All rights reserved
Dragino Wiki v2.0