Wiki source code of LoRaWAN Communication Debug

Version 27.1 by Xiaoling on 2022/05/26 17:01

Hide last authors
Xiaoling 4.1 1 **~ Contents:**
Xiaoling 1.1 2
Xiaoling 4.20 3 (((
4
5 )))
6
Xiaoling 1.1 7 {{toc/}}
8
9
10 = 1. OTAA Join Process Debug =
11
12 These pages are useful to check what is wrong on the Join process. Below shows the four steps that we can check the Join Process.
Xiaoling 2.1 13 \\**If user has checked below steps and still can't solve the problem, please send us (support @ dragino.com) the sceenshots for each step to check. They include:**
Xiaoling 1.1 14
15 * End node console to show the Join freuqency and DR. (If possible)
16 * Gateway (from gateway UI) traffic to show the packet got from end node and receive from Server. (If possible)
17 * Gateway traffic (from server UI) to shows the data exchange between gateway and server. (Normaly possible)
18 * End Node traffic (from server UI) to shows end node activity in server. (Normaly possible)
19 * End Node Keys screen shot shows in end node and server. so we can check if the keys are correct. (In most case, we found keys doesn't match, especially APP EUI)
20
21 **~1. End Device Join Screen shot, we can check:**
22
23 * If the device is sending join request to server?
24 * What frequency the device is sending?
25
Xiaoling 23.2 26 [[image:image-20220526164956-15.png]]
Xiaoling 1.1 27
28 Console Output from End device to see the transmit frequency
29
30
31 **2. Gateway packet traffic in gateway web or ssh. we can check:**
32
33 * If the gateway receive the Join request packet from sensor? (If this fail, check if the gateway and sensor works on the match frequency)
34 * If the gateway gets the Join Accept message from server and transmit it via LoRa?
35
Xiaoling 10.2 36 [[image:image-20220526163608-2.png]]
Xiaoling 1.1 37
38 Console Output from Gateway to see packets between end node and server.
39
40
41 **3. Gateway Traffic Page in LoRaWAN Server**
42
43 * If the Join Request packet arrive the gateway traffic in server? If not, check the internet connection and gateway LoRaWAN server settings.
44 * If the server send back a Join Accept for the Join Request? if not, check if the keys from the device match the keys you put in the server, or try to choose a different server route for this end device.
45 * If the Join Accept message are in correct frequency? If you set the server to use US915 band, and your end node and gateway is EU868, you will see the Join Accept message are in US915 band so no possible to Join success.
46
Xiaoling 13.2 47 [[image:image-20220526163633-3.png]]
Xiaoling 1.1 48
49 The Traffic for the End node in the server, use TTN as example
50
51
52 **4. Data Page in LoRaWAN server**
53
54 * If this data page shows the Join Request message from the end node? If not, most properly you have wrong settings in the keys. Keys in the server doesn't match the keys in End Node.
55
Xiaoling 13.2 56 [[image:image-20220526163704-4.png]]
Xiaoling 1.1 57
58 The data for the end device set in server
59
Xiaoling 13.2 60 [[image:image-20220526163732-5.png]]
Xiaoling 1.1 61
62 Check if OTAA Keys match the keys in device
63
64
Xiaoling 2.1 65 = 2. Notice of US915/CN470/AU915 Frequency band =
Xiaoling 1.1 66
Xiaoling 4.2 67 (((
Xiaoling 1.1 68 If user has problem to work with lorawan server in band US915/AU915/CN470, he can check:
Xiaoling 4.2 69 )))
Xiaoling 1.1 70
Xiaoling 4.2 71 * (((
72 What **sub-band** the server support ?
73 )))
74 * (((
75 What is the **sub-band** the gateway support ?
76 )))
77 * (((
78 What is the **sub-band** the end node is using ?
79 )))
Xiaoling 1.1 80
Xiaoling 4.2 81 (((
Xiaoling 1.1 82 All of above should match so End Node can properly Join the server and don't have packet lost.
Xiaoling 4.2 83 )))
Xiaoling 1.1 84
Xiaoling 4.2 85 (((
86
87 )))
88
89 (((
Xiaoling 1.1 90 In LoRaWAN protocol, the frequency bands US915, AU915, CN470 each includes at least 72 frequencies. Many gateways support only 8 or 16 frequencies, and server might support 8 frequency only. In this case, the OTAA join time and uplink schedule is long and unpredictable while the end node is hopping in 72 frequencies, because the end node will send data in many frequency that the gateway or server doesn,t support.
Xiaoling 4.2 91 )))
Xiaoling 1.1 92
Xiaoling 4.2 93 (((
94
95 )))
96
97 (((
Xiaoling 1.1 98 Here are the freuqency tables for these bands as reference:
Xiaoling 4.2 99 )))
Xiaoling 1.1 100
Xiaoling 14.2 101 [[image:image-20220526163801-6.png]]
Xiaoling 1.1 102
103 US915 Channels
104
Xiaoling 18.2 105 [[image:image-20220526163926-7.png]]
Xiaoling 1.1 106
107 AU915 Channels
108
Xiaoling 18.2 109 [[image:image-20220526163941-8.png]]
Xiaoling 1.1 110
Xiaoling 4.4 111 (((
Xiaoling 1.1 112 CN470 Channels
Xiaoling 4.4 113 )))
Xiaoling 1.1 114
Xiaoling 4.3 115 (((
Xiaoling 1.1 116 If we look at the [[TTN network server frequency plan>>url:https://www.thethingsnetwork.org/docs/lorawan/frequency-plans.html]], we can see the US915 frequency band use the channel 8~~15.So the End Node must work at the same frequency in US915 8~~15 channels for TTN server.
Xiaoling 4.3 117 )))
Xiaoling 1.1 118
Xiaoling 18.2 119 [[image:image-20220526164052-9.png]]
Xiaoling 1.1 120
Xiaoling 4.4 121 (((
Xiaoling 1.1 122 TTN FREQUENCY PLAN
Xiaoling 4.4 123 )))
Xiaoling 1.1 124
Xiaoling 4.3 125 (((
Xiaoling 1.1 126 In dragino end node, user can use AT+CHE command to set what frequencies set the end node will use. The default settings for Dragino end node are preconfigure for TTN server, so use 8~~15 channels, which is **AT+CHE=2**. (AT+CHE=1 for first 8 channels, AT+CHE=2 for second 8 channels.. etc, and AT+CHE=0 for all 72 channels. )
Xiaoling 4.3 127 )))
Xiaoling 1.1 128
129
Xiaoling 2.1 130 = 3. Why i see data lost/unperiocially uplink data? Even the signal strength is good =
Xiaoling 1.1 131
132 In this case, we can check if the frequency band matches in End Node, Gateway and LoRaWAN server. A typical case is using US915 in ChirpStack server as below:
133
Xiaoling 2.1 134 * **End node** ~-~-> Use Sub-band2 (Channel 8,9,10,11,12,13,14,15) for Dragino Sensor. ADR is also enable, this is the default settings for dragino sensors.
135 * **Gateway** ~-~-> Use Sub-band2 (Channel 8,9,10,11,12,13,14,15) for Dragino Gateway. this is the default settings for dragino sensors.
136 * **LoRaWAN server** ~-~-> ChirpStack default installation and use Sub-band1, **enabled_uplink_channels=[0, 1, 2, 3, 4, 5, 6, 7]** in the file chirpstack-network-server.toml.
Xiaoling 1.1 137
Xiaoling 4.3 138 (((
Xiaoling 1.1 139 When Sensor power on, it will use sub-band2 to join the network, the frequency matches the settings in gateway so all Join Request will be passed to the server for Join. Server will ask the sensor to change to Sub-band1 in the Join Accept downlink message. Sensor will change to sub-band1 for data upload. This cause the sensor and gateway have different frequencies so user see lost of most data or even no data.
Xiaoling 4.3 140 )))
Xiaoling 1.1 141
Xiaoling 4.3 142 (((
143
144 )))
145
146 (((
Xiaoling 1.1 147 Use Subband2 as a default subband cause the sensor to have problem to work with the LoRaWAN server which use other subband, and use need to access to the end node to change the subband by console. that is not user frendily,. So since Dragino LoRaWAN Stack version DLS-005(release on end of 2020), we have changed the device to use All Subbands for OTAA join, for example, device will use the first frequency in Sub-Band1 as firt OTAA join packet, then use the first frequency in Sub-Band 2 , then first frequency in sub-band 3, and so on. LoRaWAN server will normally provide the required subband in the OTAA accept process, so end node will know what subband it use after join. If LoRaWAN server doesn't provide subband info in OTAA join, end node will use the subband which join success as the working subband. So the new method cause a longer OTAA Join time but will be compatible with all LoRaWAN server. And new method won't affect the normal uplink after Join Success.
Xiaoling 4.3 148 )))
Xiaoling 1.1 149
150
Xiaoling 2.1 151 = 4. Transmision on ABP Mode =
Xiaoling 1.1 152
Xiaoling 4.3 153 (((
Xiaoling 1.1 154 In ABP mode, there is a Frame Counter Checks. With this check enabled, the server will only accept the frame with a higher counter. If you reboot the device in ABP mode, the device will start from count 0, so you won't be able to see the frame update in server.
Xiaoling 4.3 155 )))
Xiaoling 1.1 156
Xiaoling 4.3 157 (((
158
159 )))
160
161 (((
Xiaoling 1.1 162 So in ABP mode, first check if the packet already arrive your gateway, if the packet arrive gatewat but didn't arrive server. Please check if this is the issue.
Xiaoling 4.3 163 )))
Xiaoling 1.1 164
Xiaoling 4.3 165 (((
166
167 )))
168
169 (((
Xiaoling 1.1 170 To solve this, disable the Frame Counter Check will solve this issue , or reset the frame counter in the device page.
Xiaoling 4.3 171 )))
Xiaoling 1.1 172
Xiaoling 18.2 173 [[image:image-20220526164508-10.png]]
Xiaoling 1.1 174
175 Disable Frame Counter Check in ABP Mode
176
177
Xiaoling 2.1 178 = 5. Downstream Debug =
Xiaoling 1.1 179
Xiaoling 2.1 180 == 5.1 How it work ==
Xiaoling 1.1 181
182 LoRaWAN End node will open two receive windows to receive the downstream data. If the downstream packets arrive the end node at these receive windows, the end node will be able to get this packet and process it.
183
Xiaoling 4.3 184 (((
Xiaoling 1.1 185 Depends on Class A or Class C, the receive windows will be a little difference,
Xiaoling 4.3 186 )))
Xiaoling 1.1 187
Xiaoling 19.2 188 [[image:image-20220526164547-11.png]]
Xiaoling 1.1 189
190 receive windows for Class A and Class C
191
192 Below are the requirement for the End Device to receive the packets.
193
194 * The End Device must open the receive windows: RX1 or RX2
195 * The LoRaWAN server must send a downstream packet, and the gateway forward this downstream packet for this end node.
196 * This downstream packet must arrive to the end node while RX1 or RX2 is open.
197 * This packet must match the frequency of the RX1 or RX2 window.
Xiaoling 2.1 198 * This packet must match the DataRate of RX1(RX1DR) or RX2 (RX2DR). **This is the common fail point, because different lorawan server might use different RX2DR and they don't info End Node via ADR message so cause the mismatch. If this happen, user need to change the RX2DR to the right value in end node. In OTAA, LoRaWAN Server will send the RX2DR setting in Join Accept message so the end node will auto adjust. but ABP uplink doesn't support this auto change.**
Xiaoling 1.1 199
Xiaoling 2.1 200 == 5.2 See Debug Info ==
Xiaoling 1.1 201
Xiaoling 4.6 202 (((
Xiaoling 2.1 203 **For LoRaWAN Server**
Xiaoling 4.6 204 )))
Xiaoling 1.1 205
Xiaoling 4.6 206 (((
Xiaoling 1.1 207 We can check if there is downlink message for this end node, use TTN for example:
Xiaoling 4.6 208 )))
Xiaoling 1.1 209
Xiaoling 4.6 210 (((
Xiaoling 1.1 211 Configure a downstream to the end device
Xiaoling 4.6 212 )))
Xiaoling 1.1 213
Xiaoling 22.2 214 [[image:image-20220526164623-12.png]]
Xiaoling 1.1 215
Xiaoling 4.6 216 (((
Xiaoling 1.1 217 Set a downstream in TTN and see it is sent
Xiaoling 4.6 218 )))
Xiaoling 1.1 219
220
Xiaoling 4.3 221 (((
Xiaoling 1.1 222 This downstream info will then pass to the gateway downstream list. and include the DR which is used (SF9BW125) in EU868 is DR3
Xiaoling 4.3 223 )))
Xiaoling 1.1 224
Xiaoling 22.2 225 [[image:image-20220526164650-13.png]]
Xiaoling 1.1 226
Xiaoling 4.6 227 (((
Xiaoling 1.1 228 Gateway Traffic can see this downstream info
Xiaoling 4.6 229 )))
Xiaoling 1.1 230
231
Xiaoling 4.6 232 (((
Xiaoling 2.1 233 **For LoRaWAN Gateway**
Xiaoling 4.6 234 )))
Xiaoling 1.1 235
Xiaoling 4.3 236 (((
Xiaoling 1.1 237 When the downstream packet appear on the traffic of Gateway page. The LoRaWAN gateway can get it from LoRaWAN server and transmit it. In Dragion Gateway, this can be checked by runinng "logread -f" in the SSH console. and see below:
Xiaoling 4.3 238 )))
Xiaoling 1.1 239
Xiaoling 22.2 240 [[image:image-20220526164734-14.png]]
Xiaoling 1.1 241
Xiaoling 4.6 242 (((
Xiaoling 1.1 243 Gateway Sent out this packet
Xiaoling 4.6 244 )))
Xiaoling 1.1 245
246
Xiaoling 4.6 247 (((
Xiaoling 2.1 248 **For End Node**
Xiaoling 4.6 249 )))
Xiaoling 1.1 250
Xiaoling 4.8 251 (((
Xiaoling 1.1 252 we can use AT Command (AT+CFG) to check the RX1 configure and RX2 configure. as below:
Xiaoling 4.8 253 )))
Xiaoling 1.1 254
Xiaoling 4.9 255 (((
256
257 )))
258
259 (((
Xiaoling 3.1 260 (% class="box infomessage" %)
Xiaoling 2.1 261 (((
Xiaoling 4.9 262 AT+RX2FQ=869525000     ~-~--> The RX2 Window frequency
263 AT+RX2DR=3      ~-~--> The RX2 DataRate
264 AT+RX1DL=1000   ~-~--> Receive Delay 1
265 AT+RX2DL=2000   ~-~--> Receive Delay 2
Xiaoling 3.1 266 )))
Xiaoling 4.9 267 )))
Xiaoling 3.1 268
269 (((
Xiaoling 4.5 270 **when the device running, we can see below info:**
Xiaoling 4.7 271 )))
Xiaoling 1.1 272
Xiaoling 4.8 273 {{{ [12502]***** UpLinkCounter= 0 *****
274 [12503]TX on freq 868500000 Hz at DR 0
275 [13992]txDone
Xiaoling 4.13 276 [15022]RX on freq 868500000 Hz at DR 0 --> RX1 window open at frequency: 868500000, DR0, after 15022-13992= 1030ms of txdone
277 [15222]rxTimeOut --> no packet arrive in RX1 window. (duration: 200ms)
278 [15987]RX on freq 869525000 Hz at DR 3 --> RX2 window open at frequency: 869525000, DR3, after 15987-13992= 1995ms of txdone
279 [16027]rxTimeOut --> no packet arrive in RX2 window. (duration: 40 ms)}}}
Xiaoling 1.1 280
Xiaoling 4.3 281 (((
Xiaoling 4.5 282
283 )))
284
Xiaoling 4.7 285 (((
Xiaoling 4.5 286 **Another message:**
Xiaoling 4.7 287 )))
Xiaoling 4.5 288
Xiaoling 4.8 289 {{{ [12502]***** UpLinkCounter= 0 *****
290 [12503]TX on freq 868100000 Hz at DR 0
291 [13992]txDone
292 [15022]RX on freq 868100000 Hz at DR 0
293 [15222]rxTimeOut
294 [15987]RX on freq 869525000 Hz at DR 3
Xiaoling 4.13 295 [16185]rxDone --> We have got the downstream packet.
Xiaoling 4.8 296 Rssi= -64
297 Receive data
298 1:0012345678}}}
Xiaoling 4.5 299
Xiaoling 22.2 300
Xiaoling 2.1 301 == 5.3 If problem doesn’t solve ==
Xiaoling 1.1 302
Xiaoling 23.2 303 (% style="color:red" %)**If user has checked below steps and still can't solve the problem, please send us (support @ dragino.com) the sceenshots for each step to check. They include:**
Xiaoling 1.1 304
305 * End node console to show the transmit freuqency and DR.
306 * Gateway (from gateway UI) traffic to show the packet got from end node and receive from Server.
307 * Gateway traffic (from server UI) to shows the data exchange between gateway and server.
308 * End Node traffic (from server UI) to shows end node activity in server.
309
Xiaoling 2.1 310 = 6. Downlink Issue ~-~- Packet REJECTED, unsupported frequency =
Xiaoling 1.1 311
Xiaoling 4.5 312 (((
Xiaoling 1.1 313 In LoRaWAN, the gatewat will use the frequency specify by the server to transmit a packet as downlink purpose. Each Frequency band has different downlink frequency. and the gateway has a frequency range limited to transmit downlink.
Xiaoling 4.5 314 )))
Xiaoling 1.1 315
Xiaoling 4.5 316 (((
317
318 )))
319
320 (((
Xiaoling 1.1 321 So if the LoRaWAN server is an AS923 server which ask the gateway to transmit at 923.2Mhz frequency, but the gateway is IN868 frequency band (support 865~~867Mhz to transmit). In the gateway log it will show something like below:
Xiaoling 4.5 322 )))
Xiaoling 1.1 323
Xiaoling 4.7 324 {{{Sat Nov 21 08:04:17 2020 daemon.info lora_pkt_fwd[1680]: ERROR~ Packet REJECTED, unsupported frequency - 923200000 (min:865000000,max:867000000)}}}
Xiaoling 1.1 325
Xiaoling 4.5 326 (((
Xiaoling 4.6 327
328 )))
329
330 (((
Xiaoling 1.1 331 In this case, please double check the gateway frequency and the server frequency band.
Xiaoling 4.5 332 )))
Xiaoling 1.1 333
334
Xiaoling 2.1 335 = 7. Decrypt a LoRaWAN Packet =
Xiaoling 1.1 336
337 ~1. LHT65 End device configure:
338
Xiaoling 2.1 339 (% class="box infomessage" %)
340 (((
Xiaoling 1.1 341 Change to ABP Mode: AT+NJM=0
Xiaoling 2.1 342 )))
Xiaoling 1.1 343
Xiaoling 2.1 344 (% class="box infomessage" %)
345 (((
Xiaoling 1.1 346 Change to fix frequency: AT+CHS=904900000
Xiaoling 2.1 347 )))
Xiaoling 1.1 348
Xiaoling 2.1 349 (% class="box infomessage" %)
350 (((
Xiaoling 1.1 351 Change to fix DR: AT+DR=0
Xiaoling 2.1 352 )))
Xiaoling 1.1 353
Xiaoling 2.1 354 [[image:https://wiki.dragino.com/images/e/e6/Decrypt_a_LoRaWAN_Packet1.jpg||alt="Decrypt a LoRaWAN Packet1.jpg" height="607" width="558"]]
Xiaoling 1.1 355
356 2. In LG02 , configure to receive above message
357
Xiaoling 2.1 358 [[image:https://wiki.dragino.com/images/c/c3/Decrypt_a_LoRaWAN_Packet2.jpg||alt="Decrypt a LoRaWAN Packet2.jpg" height="337" width="558"]]
Xiaoling 1.1 359
360 In LG02 console, we can see the hex receive are:
361
Xiaoling 2.1 362 [[image:https://wiki.dragino.com/images/f/f1/Decrypt_a_LoRaWAN_Packet3.jpg||alt="Decrypt a LoRaWAN Packet3.jpg" height="179" width="558"]]
Xiaoling 1.1 363
364 3. Decode the info in web
365
366 [[https:~~/~~/lorawan-packet-decoder-0ta6puiniaut.runkit.sh>>url:https://lorawan-packet-decoder-0ta6puiniaut.runkit.sh/]]
367
368 Need these three fields:
369
370 LoRa packet hex format: 40c1190126800100024926272bf18bbb6341584e27e23245 (from LG02)
371
372 AT+NWKSKEY=00 00 00 00 00 00 00 00 00 00 00 00 00 00 01 11 (End node Network Session Key)
373
374 AT+APPSKEY=00 00 00 00 00 00 00 00 00 00 00 00 00 00 01 11 (End Node App Session Key)
375
376 [[https:~~/~~/lorawan-packet-decoder-0ta6puiniaut.runkit.sh/?data=40c1190126800100024926272bf18bbb6341584e27e23245&nwkskey=00000000000000000000000000000111&appskey=00000000000000000000000000000111>>url:https://lorawan-packet-decoder-0ta6puiniaut.runkit.sh/?data=40c1190126800100024926272bf18bbb6341584e27e23245&nwkskey=00000000000000000000000000000111&appskey=00000000000000000000000000000111]]
377
Xiaoling 2.1 378 [[image:https://wiki.dragino.com/images/7/77/Decrypt_a_LoRaWAN_Packet4.png||alt="Decrypt a LoRaWAN Packet4.png" height="390" width="558"]]
Xiaoling 1.1 379
Xiaoling 4.10 380 (((
Xiaoling 4.11 381 The FRMPayload is the device payload.
Xiaoling 4.10 382 )))
Xiaoling 1.1 383
384
Xiaoling 2.1 385 = 8. Why i see uplink 0x00 periodcally on the LHT65 v1.8 firmware =
Xiaoling 1.1 386
387 Since firmware v1.8, LHT65 will send MAC command to request time, in the case if DR only support max 11 bytes, this MAC command will be bundled to a separate uplink payload with 0x00.
388
Xiaoling 2.1 389 = 9. Why do I see a "MIC Mismatch" error message from the server? =
Xiaoling 1.1 390
Xiaoling 4.7 391 (((
Xiaoling 1.1 392 1)If the user receives a "MIC Mismatch" message after registering the node on the server.
Xiaoling 4.7 393 )))
Xiaoling 1.1 394
Xiaoling 4.7 395 (((
Xiaoling 1.1 396 It is likely that the user filled in the wrong APPKEY when registering the node. Many users fill in "APPSKEY".
Xiaoling 4.7 397 )))
Xiaoling 1.1 398
Xiaoling 4.7 399 * (((
400 Please note the distinction between "APPKEY" and "APPSKEY".
401 )))
Xiaoling 1.1 402
Xiaoling 4.7 403 (((
Xiaoling 1.1 404 2)If the node works on the server for a period of time, the device stops working and receives a "MIC Mismatch" message.
Xiaoling 4.7 405 )))
Xiaoling 1.1 406
Xiaoling 4.7 407 (((
Xiaoling 1.1 408 The user needs a USB-TTL adapter to connect the serial port to modify the node APPKEY.
Xiaoling 4.7 409 )))
Xiaoling 1.1 410
Xiaoling 4.7 411 * (((
412 If a node is registered with multiple servers, it may also cause the "mic mismatch" error.
Edwin Chen 5.1 413
414
Xiaoling 4.7 415 )))
Xiaoling 1.1 416
Xiaoling 2.1 417 = 10. Why i got the payload only with "0x00" or "AA~=~="? =
Xiaoling 1.1 418
Xiaoling 4.16 419 * If you are using US915, AU915 and AS923 frequencies.This is normal phenomenon.
Xiaoling 1.1 420
Xiaoling 4.7 421 (((
Xiaoling 4.19 422 When using the frequency mentioned above, the server sometimes adjusts the rate of the node, because the node defaults to the adaptive rate.
Xiaoling 4.7 423 )))
Xiaoling 1.1 424
Xiaoling 4.7 425 (((
Xiaoling 4.19 426 When the server adjusts your node rate to 0, the maximum payload length is 11 bytes. The server sometimes sends an ADR packet to the node,and the node will reply to the server after receiving the ADR packet, but the number of payload bytes exceeds the limit,so it will send a normal uplink packet, and an additional 00 data packet.
Xiaoling 4.7 427 )))
Xiaoling 1.1 428
Xiaoling 4.7 429 * (((
430 Solution: Use the decoder to filter out this 00 packet.
431 )))
432 * (((
Edwin Chen 6.1 433 Some node decoders may not have filtering function, or you need decoders of other servers and formats. Please send an email to [[david.huang@dragino.cc>>mailto:david.huang@dragino.cc]]
434
435
436
Xiaoling 4.7 437 )))
Xiaoling 1.1 438
Edwin Chen 5.1 439 = 11. Why my Dev EUI and APP EUI is 0x000000000000, how to solve? =
440
Edwin Chen 7.1 441 It is possible the keys is erased during upgrading of firmware. and the console output shows below after AT+CFG
Edwin Chen 5.1 442
443 AT+APPKEY=00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
444
445 AT+NWKSKEY=00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
446
447 AT+APPSKEY=00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
448
449 AT+APPEUI=00 00 00 00 00 00 00 00
450
451
452 You can get the keys from the box sticker or send mail to Dragino Support to check keys with the provided SN number.
453
454 You can rewrites the keys by running commands in AT Console
455
Bei Jinggeng 8.1 456 For example:
Edwin Chen 5.1 457
Bei Jinggeng 8.1 458 AT+APPKEY=85 41 47 20 45 58 28 14 16 82 A0 F0 80 0D DD EE
Edwin Chen 5.1 459
Bei Jinggeng 8.1 460 AT+NWKSKEY=AA CC B0 20 30 45 37 32 14 1E 14 93 E2 3B 20 11
461
462 AT+APPSKEY=11 23 02 20 30 20 30 60 80 20 20 30 30 20 10 10
463
464 AT+APPEUI=2C 45 47 E3 24 12 23 24
465