<
From version < 92.1
edited by Edwin Chen
on 2025/01/29 20:30
To version < 89.1 >
edited by Mengting Qiu
on 2024/01/29 19:29
Change comment: Uploaded new attachment "image-20240129192908-24.png", version {1}

Summary

Details

Page properties
Author
... ... @@ -1,1 +1,1 @@
1 -XWiki.Edwin
1 +XWiki.ting
Content
... ... @@ -193,13 +193,7 @@
193 193  LoRaWAN End node will open two receive windows to receive the downstream data. If the downstream packets arrive the end node at these receive windows, the end node will be able to get this packet and process it.
194 194  
195 195  (((
196 -Depends on Class A or Class C, the receive windows will be a little difference. The main difference between Class A and Class C:
197 -
198 -* **Class A** : Suitable for Battery powered end node. Class A will save a lot of power but it can only receive downlink after each uplink
199 -* **Class C**: End node can receive downlink immediately but have higher power consumption.
200 -
201 -
202 -
196 +Depends on Class A or Class C, the receive windows will be a little difference.
203 203  )))
204 204  
205 205  [[image:image-20220531161828-1.png]]
... ... @@ -396,43 +396,37 @@
396 396  
397 397  
398 398  
399 -(% style="color:blue" %)**3. Decode the info in CMD(Command prompt window)**
393 +(% style="color:blue" %)**3. Decode the info in SecureCRT**
400 400  
401 -LoRa packet Base64 format:  QP~/~/~/~/+AFQACZv8Hjmc8gFTAkhMzU+75 **(from LPS8-v2)**
395 +[[SecureCRT - The rock-solid Telnet and SSH client for Windows, Mac, and Linux (vandyke.com)>>url:https://www.vandyke.com/products/securecrt/]]
402 402  
397 +LoRa packet Base64 format:  QP~/~/~/~/+AFQACZv8Hjmc8gFTAkhMzU+75 (from LPS8-v2)
398 +
403 403  Then the instructions and format parsed in SecureCRT are:  ./node_modules/.bin/lora-packet-decode ~-~-base64 QP~/~/~/~/+AFQACZv8Hjmc8gFTAkhMzU+75
404 404  
405 405  
406 -**Step1: Open CMD, Enter the gateway IP and port.(ssh root@gateway IP -p 22)**
402 +**Step1: In the SecureCRT access gateway control interface, enter the command to download the parsing package: npm install lora-packet.**
407 407  
408 -[[image:image-20240129190752-17.png||height="338" width="901"]]
404 +[[image:image-20240129173810-9.png||height="389" width="1070"]]
409 409  
410 -[[image:image-20240129191937-21.png||height="450" width="901"]]
406 +[[image:image-20240129173932-10.png||height="350" width="1084"]]
411 411  
408 +[[image:image-20240129174125-11.png||height="338" width="1078"]]
412 412  
413 -**Step2: Enter the command to download the LoRa parsing package.(npm install lora-packet)**
414 414  
415 -[[image:image-20240129192239-22.png||height="416" width="902"]]
411 +**Step2: Parse the raw data from the gateway.**
416 416  
417 -[[image:image-20240129192549-23.png||height="459" width="898"]]
413 +[[image:image-20240129174948-14.png]]
418 418  
419 419  
420 -**Step3: Parse the gateway raw payload.(./node_modules/.bin/lora-packet-decode ~-~-base64 QP~/~/~/~/+AFQACZv8Hjmc8gFTAkhMzU+75)**
416 +[[image:image-20240129175037-15.png||height="619" width="1144"]]
421 421  
422 422  
423 423  
424 424  
425 -[[image:image-20240129192908-24.png||height="477" width="907"]]
426 426  
427 427  
428 -[[image:image-20240129192954-25.png||height="485" width="916"]]
429 429  
430 -
431 -
432 -
433 -
434 -
435 -
436 436  = 8. Why I see uplink 0x00 periodically on the LHT65 v1.8 firmware =
437 437  
438 438  
image-20240129192954-25.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.ting
Size
... ... @@ -1,1 +1,0 @@
1 -62.4 KB
Content
Copyright ©2010-2024 Dragino Technology Co., LTD. All rights reserved
Dragino Wiki v2.0