... ... @@ -1,1 +1,1 @@
1 -XWiki.Bei
1 +XWiki.Xiaoling
Content
... ... @@ -215,6 +215,7 @@
215 215  * This packet must match the DataRate of RX1(RX1DR) or RX2 (RX2DR). (% style="color:red" %)**This is the common fail point, because different lorawan server might use different RX2DR and they don't info End Node via ADR message so cause the mismatch. If this happen, user need to change the RX2DR to the right value in end node. In OTAA, LoRaWAN Server will send the RX2DR setting in Join Accept message so the end node will auto adjust. but ABP uplink doesn't support this auto change.**
216 216  
217 217  
218 +
218 218  == 5.2 See Debug Info ==
219 219  
220 220  
... ... @@ -331,6 +331,7 @@
331 331  * End Node traffic (from server UI) to shows end node activity in server.
332 332  
333 333  
335 +
334 334  = 6. Downlink Issue ~-~- Packet REJECTED, unsupported frequency =
335 335  
336 336  
... ... @@ -459,29 +459,13 @@
459 459  
460 460  When using the frequency mentioned above, the server sometimes adjusts the Data Rate (DR) of the node, because the end node has Adaptive Data Rate (ADR) Enabled.
461 461  
462 -1.
463 -
464 464  When the server adjusts end node data rate to 0, the maximum payload length is 11 bytes. The server sometimes sends an ADR packet to the end node, and the node will reply to the server after receiving the ADR packet, but the number of payload bytes exceeds the limit, so it will send a normal uplink packet, and following an additional 00 data packet to handle this MAC command response.
465 465  
466 -2.
467 467  
468 -The server downlinks a calibration time package
469 -This calibration time packet will exceed the byte limit, causing its payload to become 00
470 -
471 471  (% style="color:blue" %)**How to solve:**
472 472  
473 -Solution:
469 +Solution: Use the decoder to filter out this 0x00 packet.
474 474  
475 -~1. Use the decoder to filter out this 0x00 packet.
476 -
477 -2. Data rate changed from DR3 to DR5, increasing upload byte length
478 -AT+ADR=0
479 -AT+DR=3
480 -
481 -Downlink:
482 -
483 -[[http:~~/~~/wiki.dragino.com/xwiki/bin/view/Main/End%20Device%20AT%20Commands%20and%20Downlink%20Command/#H7.4DataRate>>http://wiki.dragino.com/xwiki/bin/view/Main/End%20Device%20AT%20Commands%20and%20Downlink%20Command/#H7.4DataRate]]
484 -
485 485  Some node decoders may not have the filter function, or you need decoders of other servers and formats. Please send an email to [[support@dragino.com>>mailto:support@dragino.com]]
486 486  